Records from 2005 to 2026. Most recent: inspection, 4 May 2026.
Inspection history · 38
4 May 2026
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8361719
16 August 2023
MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7769691
10 July 2023
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7738322
12 October 2022
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7574145
24 January 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7384199
21 June 2021
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7228913
27 February 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6916969
2 November 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6847068
2 November 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6847608
25 May 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6418330
17 November 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6308896
17 November 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6308909
25 April 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6130669
15 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5743318
10 August 2015
Deficiency Check · Administrative Inspection · ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5201992
26 June 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4893440
25 June 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4899243
8 May 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4305137
29 July 2011
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4098373
28 July 2011
MTSA/ISPS Verification · Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4094675
28 July 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4097258
21 July 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4089391
26 February 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3953039
30 December 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3917602
19 December 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3912375
17 October 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3871367
14 October 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3877438
12 March 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3493041
2 October 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3337039
12 February 2008
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 3134692
29 October 2007
Ballast Water Examination · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3086042
10 June 2007
Type not recorded
No type recorded · Activities Europe · Activity 3431516
7 June 2007
Type not recorded
No type recorded · Activities Europe · Activity 2954206
28 March 2006
In-Service Inspection · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2602668
15 February 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2585680
26 September 2005
MARPOL Annex V Examination · Reflagging & Initial Certification · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2500400
12 September 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2490444
12 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2490446
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 10 August 2015
Resolved
1430 - Engineering - Each emergency generating set shall be provided with a second source of energy for starting. Ship's manually charged hydraulic accumulator is not capable of starting the emergency generator. - 74 SOLAS 04 II-1/44.2
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2015
Resolved 10 August 2015
Resolution: Recieved class report attesting to the repair of the hydraulic accumulator. Part was repaired to the satisfaction of the surveyor (DNV-GL) and engine is starting and operating properly.
Construction/Loadline › Hull › Hull Plating
Issued 12 February 2008
Resolved
Crop and renew inset area located starboard side aft near the ramp. Testing should be in the presence of a USCG Marine Inspector and/or attending Class Surveyor.
Condition: Unknown
Due 12 March 2008
Resolved 24 February 2008
Construction/Loadline › Hull › Bottom Plating
Issued 12 February 2008
Resolved
Renew all wasted zincs on the vessel's rudder.
Condition: Unknown
Due 12 March 2008
Resolved 24 February 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 28 September 2005
Resolved
Install and prove proper operation of pneumatically activated and pneumatically operated Low Pressure CO2 audible alarms, equipment shutdowns, and discharge timers in all fixed fire fighting protected spaces.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 27 March 2006
Resolution: All zones have pneumatic timers and all alarms have had supplemental pneumatically operated sirens installed at all locations. System alterations have been submitted and approved by MSC.