MAURY USCG vessel records Sign in
← All vessels

SIR WINSTON

SIR WINSTON is a 2005 passenger vessel (inspected). The Coast Guard has recorded 6 inspections since 2005, most recently in December 2007, along with 59 deficiencies.

Records from 2005 to 2007. Most recent: inspection, 6 December 2007.

Built
2005
Last inspected
6 December 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7683
792269
Flag
UNITED STATES
367075120 (licence lapsed)
Maury page id
psix-792269

Inspections, by type

Years with a record 3 calendar years (2005–2007)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it240 - Convention (Subpart B), Net Ton
88 - Regulatory (Subpart C or D), Net Ton
694 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC7683MMSI 367075120 · cancelled · compulsorily equipped · granted 5 November 2005, cancelled 25 February 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 6

6 December 2007 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3110536
4 October 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2793604
20 January 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2570084
9 January 2006 Initial Certification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563289
2 December 2005 Initial Construction-Excluding Oversight · Hull Examination · Inclining Experiment · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2543204
19 January 2005 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2876017

Deficiency record · 59

Communications › Radio Communications › VHF Radiotelephone
Issued 18 May 2006 Resolved
Provide an FCC Small Passenger Vessel, Safety Radio Certificate per 46 CFR 80.59 (2) and bridge to bridge radio certificate.
Due 26 May 2006
Resolved 25 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2006 Resolved
Provide approved electrical plans for both the A/C and D/C systems and satifactorly address al comments.
Due 18 June 2006
Resolved 12 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 February 2006 Resolved
Re-locate pressure activated switches outside the protected space per the manufacturer drawing and the installation manual. Prove proper operation of system when complete.
Action required: 705 - Other - as specified
Due 7 February 2006
Resolved 11 May 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 February 2006 Resolved
Provide proper and approved plans for CO2 fire suppression system.
Due 2 February 2006
Resolved 8 May 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 February 2006 Resolved
Provide approved plans as listed on plan submittal form.
Due 2 February 2006
Resolved 8 May 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 February 2006 Resolved
Provide approved electrical plan for emergency lighting system for engine room and any other spaces served ( combination battery and DC -AC converter).
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 8 May 2006
Resolution: Converter was removed. Emergnecy lighting is battery only.
Personnel › Training › Familiarization Training
Issued 2 February 2006 Resolved
Perform drills in the presence of a Marine Inspector.
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 8 May 2006
Documentation › Certificates/Documents › Stability Letter
Issued 2 February 2006 Resolved
Provide a proper and approved stability letter.
Due 2 February 2006
Resolved 7 February 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 2 February 2006 Resolved
Provide a FCC Small Passernger Vessel, Safety Radio certificate per 46 CFR 80.59 (2).
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 3 October 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 February 2006 Resolved
Provide a copy of the service report on the CO2 system testing and repairs.
Due 2 February 2006
Resolved 7 February 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 1 February 2006 Resolved
Prove proper operation of CO2 heat activated dectectors.
Due 1 February 2006
Resolved 2 February 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 9 January 2006 Resolved
Install engine room ventilation system in accordance with approved plan or edit plan and resubmit for approval.
Action required: 705 - Other - as specified
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2006 Resolved
Re-submit electrical plans for approval showing the as built condition of vessel ( Pilot House relocated).
Action required: 705 - Other - as specified
Resolved 8 May 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 January 2006 Resolved
Re-locate mast head light or side lights to show mast head light forward of side lights per Navigation rules Annex 1 para 3 (b).
Action required: 705 - Other - as specified
Resolved 21 March 2006
Communications › Internal Communications System › Engine Order Telegraph System
Issued 9 January 2006 Resolved
Prove Micro Commander engine controls meet the requirements of 46 CFR 62 refenced by 46 CFR 121.620 (d). (operation, indicators, remote and local control, communication).
Action required: 705 - Other - as specified
Resolved 8 March 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 9 January 2006 Resolved
Perform an underway sea trail of the vessel in the presents of a Marine Inspector to verify handling charatristics, bridge visibility, and systems function.
Action required: 705 - Other - as specified
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2006 Resolved
Provide approved electrical plans for both the A/C and D/C systems and satisfactorly address all comments.
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 3 October 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 December 2005 Resolved
Provide onboard the required station bill. (46 CFR 122.514)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 December 2005 Resolved
Provide onboard the Passenger Safety Bill. (46 CFR 122.515)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Resolution: Not applicable, not more than 49 overnight.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 2 December 2005 Resolved
Provide onboard waste management plan / instructions. (33 CFR 151.57)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 December 2005 Resolved
Provide onboard the emergency instruction list. (46 CFR 122.510)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Navigation › Piloting/Steering › Marine Charts
Issued 2 December 2005 Resolved
Provide onboard the required navigation publications. (46 CFR 121.420)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Communications › Internal Communications System › Sound-powered Telephone
Issued 2 December 2005 Resolved
Conduct an operational test of the internal communications system. (46 CFR 121.602)
Action required: 705 - Other - as specified
Resolved 21 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 2 December 2005 Resolved
Provide the emergency broadcast placard. (46 CFR 121.506)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 2 December 2005 Resolved
Conduct an operational test of the public address system. (46 CFR 121.610)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Stability › Intact Righting Energy › General
Issued 2 December 2005 Resolved
Mark the upper decks capacity per the stability letter. (46 CFR 122.602(g))
Action required: 705 - Other - as specified
Resolved 8 May 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 December 2005 Resolved
Provide onboard the lifejacket donning placard. (46 CFR 122.516)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Lifesaving › Lifebuoys › Quantity
Issued 2 December 2005 Resolved
Outfit the vessel with the required number and properly equipped ring life buoys. (46 CFR 117.70)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 December 2005 Resolved
Provide proper stowage for the lifejackets. (46 CFR 117.78)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 December 2005 Resolved
Provide onboard a first aid kit. (46 CFR 121.710)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 December 2005 Resolved
Submit for approval to the cognizant Officer in Charge, Marine Inspection (Miami) the fire control plan and post same. (46 CFR 116.530)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 2 December 2005 Resolved
Conduct an operational installation test of the fire and smoke detection system after submission of the system plans. (46 CFR 118.400(e)
Action required: 705 - Other - as specified
Resolved 2 February 2006
Fire Fighting › Fire Hoses › Connections
Issued 2 December 2005 Resolved
Provide for each fire hose station a suitable spanner wrench. (46 CFR 118.320)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Resolution: Spanners onoboard, but not required, less than 600 pax, less than 49 overnight
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 December 2005 Resolved
Conduct an operational test of the wet exhaust system for the internal combustion engines loss of cooling water alarm. (46 CFR 119.425)
Action required: 705 - Other - as specified
Resolved 8 May 2006
Engineering › Bilge Water Management System › Piping
Issued 2 December 2005 Resolved
Conduct an operational test of the bilbe high level alarms. (46 CFR 119.530)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 December 2005 Resolved
Provide onboard portable lighting required by 46 CFR 120.430.
Action required: 705 - Other - as specified
Due 9 January 2006
Resolved 9 January 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 December 2005 Resolved
Install automatic electric emergency lighting in way of the inclined stair to the aft staterooms and engine room. (46 CFR 120.432)
Action required: 705 - Other - as specified
Resolved 9 January 2006
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 2 December 2005 Resolved
Conduct an operational test of all "FIRE" pull boxes.
Action required: 705 - Other - as specified
Resolved 1 February 2006
Documentation › Markings/Placards › Oil Discharge Placard
Issued 2 December 2005 Resolved
Post the pollution placard required by 33 CFR 155.450.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Documentation › Markings/Placards › Garbage Placard
Issued 2 December 2005 Resolved
Post the MARPOL V placard required by 33 CFR 151.59.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electric Supply System (service) › Cable
Issued 2 December 2005 Resolved
Pour / seal the deck MCT in the Pilot house, starboard side.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 2 December 2005 Resolved
In the pilot house properly band all electrical cables. (46 CFR 120.340(b)).
Action required: 705 - Other - as specified
Resolved 9 January 2006
Fire Fighting › Structural - Main Vertical Zones › General
Issued 2 December 2005 Resolved
Conduct an operational test of the fire screen door automatic hold back release and ensure proper closure of all fire screen doors.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 December 2005 Resolved
Conduct a weight test and operational test of all safety devices for the elevator.
Action required: 705 - Other - as specified
Resolved 2 February 2006
Electrical › Lighting (service) › Conductor
Issued 2 December 2005 Resolved
Properly band the electrical cable for the nav. lights on the upper deck.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 2 December 2005 Resolved
Properly band the electrical cables in all spud rooms / closets.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electric Supply System (service) › Cable
Issued 2 December 2005 Resolved
Properly band the electrical cables behind the washer and dryer in the galley.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electric Supply System (service) › Cable
Issued 2 December 2005 Resolved
Properly seal the electrical deck penetrations behind the washer and dryer in the galley.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 December 2005 Resolved
Provide the proper cover for the "wet" receptical box in the bow thruster room.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electric Supply System (service) › Cable
Issued 2 December 2005 Resolved
Properly band the electrical cables in the bow thruster room.
Action required: 705 - Other - as specified
Resolved 21 March 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 December 2005 Resolved
Install floor plates in the bow thruster room.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 December 2005 Resolved
Make properly operable the emergency light installed in way of the forward, below main deck storerooms.
Action required: 705 - Other - as specified
Resolved 2 February 2006
Electrical › Electric Supply System (service) › Cable
Issued 2 December 2005 Resolved
Properly band the electrical cables in the forward below main deck storerooms.
Action required: 705 - Other - as specified
Resolved 2 February 2006
Stability › Watertight Integrity › General
Issued 2 December 2005 Resolved
Install mounting brackets for the remote operation hand held levers for the sliding watertight door.
Action required: 705 - Other - as specified
Resolved 2 February 2006
Fire Fighting › Fire Pumps › Pressure
Issued 2 December 2005 Resolved
Install a suitable discharge pressure gauge for the fire pump.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 December 2005 Resolved
Mark the emergency lights installed in the engine room.
Action required: 705 - Other - as specified
Resolved 9 January 2006
Electrical › Electric Supply System (service) › Cable
Issued 2 December 2005 Resolved
Properly band all electrical cables in the engine room
Action required: 705 - Other - as specified
Resolved 2 February 2006
Documentation › Markings/Placards › Warning Signs
Issued 2 December 2005 Resolved
Provide all required markings in accordance with 46 CFR 122.602 through 122.614.
Action required: 705 - Other - as specified
Resolved 2 February 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 2 December 2005 Resolved
Provide on board and properly mount the following hand portable fire extinguishers: Main Deck Aft - AII; 02 Deck Aft - AII; Engine Room, Port Side - BII; Forward Store Rooms (outside space) - AII. (46 CFR 118.500(a))
Action required: 705 - Other - as specified
Resolved 2 February 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.