Behind this panel: 10 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 10
30 October 2025
Deficiency Check · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8260691
27 January 2025
Drydock Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8076458
14 November 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7831877
29 November 2022
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7602926
3 November 2020
COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7089129
30 September 2019
Annual Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6825085
19 November 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6583861
21 November 2017
Drydock Exam · DAPI Audit · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6311015
3 September 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6260377
4 November 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6051017
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 30 October 2025
Resolved
Each officer employed on any vessel must have his or her license onboard and available for examination at all times when the vessel is operating. Current master has a license for inland waters. Provide a master with proper credentials for the route to be sailed, near coastal license.
46 CFR 185.402
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2025
Resolution: Master provided who had correct license.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's fuel shutoff valve at tank was missing. Provide fuel shutoff.
46 CFR 182.455(b)(4)
Action required: 10 - Deficiency Rectified
Resolved 30 October 2025
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 30 October 2025
Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery expiration was not located on EPIRB. Provide new battery or new EPIRB prior to taking passengers.
46 CFR 185.728
Action required: 10 - Deficiency Rectified
Resolved 30 October 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2025
Resolved
Spaces required to have fixed fire extinguishing systems include A space containing a fuel tank for gasoline. TheCOI for the vessel states a fixed dry chemical extinguisher is installed in the fuel tank space with a 8 cubic foot capacity. This system is not in place on the vessel. Provide fixed fire fighting on vessel or provide proof of meeting Work Instruction 7 fire fighting section.
46 CFR 181.400(a)(5)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2025
Resolution: Fuel tank space meets Work Instruction 7 execption. Removed fixed fire extinguisher requirement.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 30 October 2025
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has areas of damage to hull into fiber glass on port side mid ship. Make proper repairs to area.
46 CFR 177.300 (c)
Action required: 10 - Deficiency Rectified
Resolved 30 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2025
Resolved
Flammable vapor detection system must be located in lowest part of a space containing a fuel tank when separate from the machinery space. Vapor sensor currently located in space that is not the tank fuel space. Mount sensor at lowest part of fuel tank space and make sure there is an ability to replace and test.
46 CFR 182.480
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2025
Resolution: Vapor detector moved to lowest part of space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 October 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational. Provide visual indicator for bilge pump.
46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 18 November 2025
Resolution: Visual indicator provided at helm.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 October 2025
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. FCC Safety Radio Certificate not issued by FCC licensed technician for radio installation. Provide inspection and valid FCC Safety Radio Certificate.
46 CFR 176.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 18 November 2025
Resolution: SafetySafety Radio Certificate provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 October 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 29 January 2026
Resolution: FCC station authorization provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 September 2019
Resolved
As per Sec Hono WI-07, RHIB inflatable sponsons must pass an overpressure test of 1.25x the MAWP. The installed tube failed the pressure test and a leak was identified between baffles. Provide a repaired or new tube and satisfactorily pass the exterior leak test and overpressure test.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2019
Resolved 2 October 2019
Resolution: A new inflatable sponson was installed and passed pontoon inflation test IAW Sec Hono WI-07.