Records from 2016 to 2022. Most recent: inspection, 19 October 2022.
Documentation record
Tonnage as PSIX records it341 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
102 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 9
19 October 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7580622
26 July 2021
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7262104
12 July 2021
Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7254289
26 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6987517
16 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6978273
5 September 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6796474
16 July 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6482989
25 May 2018
Examination of Repairs · Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6423596
18 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6134798
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 October 2022
Resolved
The combined weight of each group of life floats must not exceed 400lbs. Life rafts grouped on both Port + Starboard were connected to the same weak link and hydrostatic release unit (HRU) exceeding 400lbs. Limited to carriage of 50 passengers until each raft has own weak link and HRU. -46CFR 180.137(e)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2022
Resolved 20 October 2022
Resolution: Each raft was provided with its own weak link, and HRU with float fee arrangement installation to the satisfaction of the lead Marine Inspector. Passenger carriage limitation removed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 October 2022
Resolved
Found potential crack in side shell IVO STBD exhaust. Prove watertight integrity of hull; repair. - 46CFR 176.802(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2022
Resolved 20 October 2022
Resolution: Crack was found to have not penetrated the side shell. Exterior crack ground down, and repaired to the satisfaction of the lead Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2022
Resolved
Protect passengers, crew, other persons from electrical hazards. Found improperly terminated electrical connection near starboard generator fan. - 46CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 20 October 2022
Resolution: Wiring repaired to the satisfaction of the lead Marine Inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 5 September 2019
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. The mates medical certificate is expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 September 2019
Resolved 5 September 2019
Resolution: Vessels routed were reduced until an addition mate arrived with valid certificates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 September 2019
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the [name withheld] #2 and #4 salt water supply to cool exhaust was found with small pin holes in the pipe. Vessel shall replace piping during next dry-dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 26 July 2021
Resolution: All piping replaced and repaired to the satisfaction of attending [name withheld] pressure tested with working pressure while underway.