Records from 2008 to 2026. Most recent: inspection, 30 April 2026.
Documentation record
Registered dimensions (L × B × D)90.9 ft × 31.3 ft × 11.4 ft
Registered tonnagegross 76 / net 52
ITC dimensions (L × B × D)90.9 ft × 31.3 ft × 11.4 ft
ITC tonnagegross 301 / net 120
BuilderYANK MARINE INC · TUCKAHOE, NJ, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHYANNIS, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
301 - Convention (Subpart B), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
120 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 43
30 April 2026
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8357275
13 January 2025
Annual Inspection · Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8062865
7 October 2024
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8015590
2 October 2024
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8013118
2 October 2024
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8016708
8 August 2024
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7977246
13 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7909881
29 September 2023
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7812804
1 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7676179
4 April 2023
Plan Review (Other than "T") · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7658196
7 October 2022
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7573355
9 June 2022
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8028336
9 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7445230
10 August 2021
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7284599
19 May 2021
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7200270
29 March 2021
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7158481
6 October 2020
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7072408
24 June 2020
DAPI Audit · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7006811
6 August 2019
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6775713
27 July 2019
Damage Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6767232
15 May 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6681073
8 April 2019
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6654273
24 August 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6521597
28 June 2018
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7142433
8 June 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6514143
28 May 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6427711
8 May 2018
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6416626
8 May 2018
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6583521
19 April 2018
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6394893
2 October 2017
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6280050
2 September 2017
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6260176
2 September 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7165082
1 September 2017
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6260142
1 September 2017
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6261889
5 May 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6139896
2 February 2017
Hull Examination · Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6077690
27 October 2016
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6031326
29 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6013078
26 September 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6048762
9 July 2016
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5937039
9 July 2016
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5937580
16 June 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5914021
27 April 2016
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5863900
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 August 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Crop and renew to good metal port inboard side vertical shell plate just fwd of cutless bearing where temporary repairs were made on 15Aug24 prior to next credit drydock April 2025.
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 4 June 2025
Resolution: See Activity number 8062865.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel lost a rudder and will be replacing in kind, make new rudder available for inspection and test to the satisfaction of the attending USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 August 2024
Resolved 15 August 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 August 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Crack noted port inboard side vertical weld above shaft log just fwd of cutless bearing. Dye pen, drill stop, V/W, and air test to the satisfaction of the attending USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 August 2024
Resolved 15 August 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2024
Resolved
EPIRB battery was expired and the test function did not work.
Action required: 10 - Deficiency Rectified
Resolved 13 May 2024
Resolution: Vessel got a new EPIRB and registered it while MI was onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 October 2020
Resolved
Port reduction gear inoperative; return to Hyannis and make repairs satisfactory to CG marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2020
Resolved 9 October 2020
Resolution: MI watched pressure fluctuate on reduction gear as vessel engaged forward and astern. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2019
Resolved
Vessel received damage to starboard propeller. Effect repairs on 29JUL19 to the satisfaction of the attending CG Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2019
Resolved 29 July 2019
Resolution: Vessel rep. replaced stbd propeller, and conducted satisfactory sea trial.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 August 2018
Resolved
Vsl is broadcasting: No IMO #, NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V), and no static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 September 2018
Resolved 14 September 2018
Engineering › Steering Gear System › Piping
Issued 28 May 2018
Resolved
Make permanent repairs to hydraulic steering piping to the satisfaction of the attending USCG Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Electrical › Electric Generation Source (service) › Generator
Issued 1 September 2017
Resolved
Vessel's port diesel generator's alternator seized up resulting in the fan/serpentine belt being destroyed. Repair and/or replace alternator along with providing a new fan belt.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 1 September 2017
Resolution: Vessel replaced alternator and a new fan belt; all sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 29 September 2016
Resolved
AVH01: Prove Proper Operation of electronic controls with attending Coast Guard Marine Inspector prior to operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 30 September 2016
Resolution: Witnessed full power trial and conducted several operational test.