Inspection history · 13
30 March 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8320683
21 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8097749
27 February 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7871221
27 March 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7657660
15 July 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7489590
6 April 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7425786
5 April 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7170774
17 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6979290
14 March 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6642743
16 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6373111
11 July 2017
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6199819
16 March 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6092943
23 February 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5823020
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 30 March 2026
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. Starboard fuel tank vent screen has holes.
46 CFR 182.20-35(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 22 April 2026
Resolution: O/O provided photos of satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 March 2026
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. All electrical installations shall be to the satisfaction of the [name withheld] wire found hanging near entrance to engine room.
46 CFR 183.01-5(a)
46 CFR 183.01-15(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 14 April 2026
Resolution: Wire capped off.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 March 2026
Resolved
Each life float shall be ... equipped with two paddles. Both paddles in life float cracked.
46 CFR 180.15-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 14 April 2026
Resolution: Paddles replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 February 2024
Resolved
A distribution line must extend at least 2 inches beyond the last orifice and be closed with a cap or plug. The distribution line lacks the additional 2 inch of line past the last orifice.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Additional line was installed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 February 2024
Resolved
Complete and simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each discharging location. The system lacks discharge instructions.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Instruction was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 February 2024
Resolved
Remote fuel shutoff stations must be marked in clear legible letters at least 1 inch high indicating purpose of the valve and direction of operation. The shutoff lacks marking.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 2 April 2024
Resolution: Confirmed marking is present.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2024
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI but must not be fewer than the minimum number required by Table 181.500(b). Vessel is required four 40 B:C and there are none on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 2 April 2024
Resolution: Received confirmation that the correct number of extinguishers are onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2024
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Starboard battery bank has temporary connections installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Permanent connections were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 February 2024
Resolved
Two letters were missing or partially missing for the vessel name on the Life Float. The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 2 April 2024
Resolution: Confirmed markings were afixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2024
Resolved
Jacket water flexible hose on port engine did not have two clamps on one end connecting to the engine. In systems and applications where, flexible hoses are permitted to be clamped: Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide positive stop against hose slippage.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 2 April 2024
Resolution: Confirmed clamps were installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 April 2022
Resolved
A small passenger vessel may not be operated without having on board a valid U.S. Coat Guard Certificate of Inspection. The vessel's COI expired 20MAR2022. The carriage of more than 6 passengers is prohibited.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2022
Resolved 12 April 2022
Resolution: Issued COI.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 April 2021
Resolved
Life float was missing retro-reflective tape and markings were faded. Repair back to original with markings and retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 April 2021
Resolved 7 April 2021
Resolution: Master corrected def. reflective tape and markings renewed.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 5 April 2021
Resolved
Distress signals - vessel had 04 red hand flares on board. Vessel is required to have 3 red hand flares and 3 orange smoke distress signals. The smoke distress signals can be substituted for 3 red hand flares or 3 rocket parachute flares.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 April 2021
Resolved 7 April 2021
Resolution: Master corrected def. aquired proper distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2021
Resolved
Child life vests do not meet 46 CFR 180.71(c). Child life vests were similar to those found in recreational boats(no retro-reflective tape, markings, etc...). Replace all children's life vest with approved type prior to the carriage of children and within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 22 April 2021
Resolution: Master acquired child's life jackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2020
Resolved
Vessel had CNG grill out on deck for use underway. Did not meet ABYC standards required per 46 CFR 184.240(e)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 June 2020
Resolved 17 June 2020
Resolution: POC removed grill from vessel on the spot.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 17 June 2020
Resolved
Vessel did not have fire axe near operating station.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 June 2020
Resolved 17 June 2020
Resolution: Fire axe was moved from engine room to operating station.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 June 2020
Resolved
Safety Radio Telephone Certificate was expired/invalid
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2020
Resolved 26 June 2020
Resolution: photo verification of document renewal
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 June 2020
Resolved
Bridge-to-bridge Radiotelephony certificate expired/invalid (47 CFR Part 17)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2020
Resolved 26 June 2020
Resolution: Photo verification of document renewal
Lifesaving › Lifefloat › Float Free
Issued 16 March 2018
Resolved
Install life float in a float free arrangement.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2018
Resolution: Master removed obstructions to lifefloat
Lifesaving › Lifefloat › Serviceable
Issued 16 March 2018
Resolved
Reseal lifefloat with marine grade sealant of appropriate color.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 March 2018
Resolved 11 April 2018
Resolution: Master resealed the lifefloat
Construction/Loadline › Structures › Scupper
Issued 16 March 2018
Resolved
Replace gasket on hatch in port generator room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 March 2018
Resolved 11 April 2018
Resolution: Gasket was replaced on hatch in port generator room.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 March 2018
Resolved
Replace battery with approved type on all waterlights.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2018
Resolution: Master replaced batteries in water lights.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2018
Resolved
Replace plastic tie wraps above main engines supporting wires and fuel line with metal bands/wraps.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 March 2018
Resolved 12 June 2018
Resolution: Master replaced plastic tie wraps with metal bands.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 16 March 2018
Resolved
Vessel needs six hand flares or 3 ornage smoke signals.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2018
Resolution: Master purchased the appropirate number of flares.
Engineering › Bilge Water Management System › Interface Detector
Issued 23 February 2016
Resolved
Provide visual indication of automatic bilge pump operation at the operating station.
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 6 April 2016
Resolution: Bilge pumps wired to produce indication in pilot house when activated from the automatic position.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 February 2016
Resolved
Remove or properly terminate exposed wires from port engine electrical panel.
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 8 March 2016
Resolution: Dead end wires were removed.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 February 2016
Resolved
Provide record of employee chemical testing from testing facility.
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 2 March 2016
Resolution: Vessel had all 03 employees chemically tested and enrolled in their system through Swedish Medical Hospital. Previous records could not be located.