Records from 1986 to 2013. Most recent: inspection, 27 February 2013.
Inspection history · 19
27 February 2013
Deficiency Check · Administration
Physical examination · USCG East District (dp) · USCG East District (CGD-E) · Activity 4540488
28 December 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2866023
11 January 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2564884
4 January 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2563588
11 October 2005
Uninspected Passenger Vessel
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2512631
20 February 2005
Type not recorded
No type recorded · Station Emerald Isle · USCG East District (CGD-E) · Activity 2296131
26 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771619
11 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 205011
30 January 1999
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1510786
5 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 645990
5 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 693641
2 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 661578
1 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212475
1 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212947
1 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213448
1 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 372999
6 May 1994
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 44317
24 January 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 71308
19 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309890
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 October 2005
Resolved
VESSELS OVERBOARD VALVE FROZEN IN THE OPEN POSITION. BYPASIING THE HOLDING TANK AND ALLOWING SEWAGE TO BE DISCHARGED DIRECTLY OVERBOARD
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2013
Resolution: Cleared deficiency for MISLE Maintenance.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 11 October 2005
Resolved
NO POLLUTION PLACARD FOUND IN THE ENGINE ROOM
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2013
Resolution: Cleared deficiency for MISLE Maintenance.
Accommodation/Occupational Safety
Issued 1 December 1994
Resolved
VSL HAD A HOLDING TANK FOR AN MSD AND RECENTLY CLEANED THE SYSTEM. AFTER CLEANING THE DIRECT DISCHARGE VALVE WAS LEFT IN THE OPEN POSITION. A CREWMEMBER FLUSHED THE TOILET AND I OBSERVED THE SYSTEM DISCHARGE INTO THE WATER. THE MASTER STATED THAT THE TANK WAS CLEANED SIX DAYS EARLIER.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Lifesaving
Issued 1 December 1994
Resolved
VSL HAD TWO RING BOUY'S ONBOARD. BOTH HAD NUMEROUS LARGE CRACKS AND WERE WORN TO THE POINT THAT THEY COULD NOT BE USED EFFECTIVELY AS A LIFE SAVING DEVICE.
Condition: Unknown
Due 3 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 1 December 1994
Resolved
VESSEL HAD FOUR PFD'S WITH FOUR PERSONS ONBOARD. ALL FOUR PFD'S WERE STOWED IN A CLOSED AREA UNDER A BUNK AND BEHIND ENGINE SPARE PARTS._x001C_ ALL WERE NOT READILY AVAILABLE.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Fire Fighting
Issued 19 June 1986
Resolved
PROVIDE ONE ADDITIONAL TYPE,U.S. COAST GUARD APPROVED,B-I OR B-II PORTABLE FIRE EXTINGUISHER ON BOARD IAW 46CFR25.30-20.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Accommodation/Occupational Safety
Issued 19 June 1986
Resolved
VESSEL DID NOT HAVE A U.S. COAST GUARD APPROVED MARINE SANITATION DEVICE ON BOARD AS REQUIRED BY 33CFR159.7(C). VESSEL HAS INSTALLED TOILETS WITH FIXED PIPING THAT DISCHARGED RAW SEWAGE DIRECTLY OVERBOARD.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Lifesaving
Issued 19 June 1986
Resolved
VESSEL DID NOT HAVE AN APPROVED PERSONNEL FLOATATION DEVICE ON BOARD FOR EACH PERSON ON BOARD (FOUR) AS REQUIRED BY 46CFR25.25-5/46USC3306. PFD'S ON BOARD (THREE) WERE NOT SERVICEABLE- THEY WERE RIPPED, TORN, DRYROTTED, &MISSING FLOATATION.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Navigation
Issued 19 June 1986
Resolved
PROVIDE A COPY OF THE INLAND NAVIGATION RULES ON BOARD IAW 33CFR88.05.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986