BLUE CHIP 2

BLUE CHIP 2 is a 2006 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2006, most recently in March 2010, along with 62 deficiencies and 2 casualty investigations in 2006.

Records from 2006 to 2010. Most recent: inspection, 2 March 2010.

Built
2006
Last inspected
2 March 2010
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8101
794928
Flag
UNITED STATES
367081690
Maury page id
psix-794928

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2006–2010)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)345.6 ft × 200.3 ft × 20.6 ft
Registered tonnagegross 39,012 / net 13,294
ITC dimensions (L × B × D)345.6 ft × 200.3 ft × 20.6 ft
ITC tonnagegross 39,012 / net 13,294
BuilderJAMESTOWN METAL MARINE SALES INC · MICHIGAN CITY, IN, UNITED STATES · built 2006
Hull materialSteel
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMICHIGAN CITY, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13294 - Convention (Subpart B), Net Ton
39012 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC8101MMSI 367081690 · active · compulsorily equipped · granted 26 November 2025, expires 15 December 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

2 March 2010 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3691697
17 February 2010 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3682405
10 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3540682
6 July 2009 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3526041
7 May 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3480231
9 April 2009 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3447462
26 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3425290
22 January 2009 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3398128
5 December 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3374723
13 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3362226
6 October 2008 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3337877
29 August 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3327222
17 July 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3263510
11 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3176035
12 February 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3146127
7 January 2008 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3126859
21 December 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3119291
16 November 2007 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3099885
15 November 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3099120
15 October 2007 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3073531
18 July 2007 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2992428
12 April 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2902970
16 February 2007 Deficiency Check · Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2874582
29 January 2007 Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2863531
19 January 2007 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2858756
23 October 2006 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2764208
19 October 2006 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2803610
6 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2770937
20 July 2006 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2718954
24 May 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2671349
17 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2656155
21 April 2006 Re-Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2630518
27 March 2006 Initial Certification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2610219
17 March 2006 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2604516

Deficiency record · 62

Fire Fighting › Structural - A Class Divisions › Doors
Issued 6 July 2009 Resolved
Prove proper operation of FSD No. 26. Door is binding at the top and will not Latch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 July 2009
Resolution: Door operates properly.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 6 July 2009 Resolved
Prove proper operation of warning horn for SFSD No. 1.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 September 2009
Resolved 5 October 2009
Resolution: Re-issued CG-835.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 6 July 2009 Resolved
Properly seal all Beverage line penitrations in the overhead of the forward QRA in accordance with 46 CFR 72.05-10 and NVIC 9-97
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 July 2009
Resolution: Lines properly sealed with fire stop.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 April 2009 Resolved
Properly adjust FSD #5 & #15 IAW 46 CFR 72.05-25.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 27 May 2009
Resolution: FSD #5/15 properly adjusted.
Lifesaving › Rescue Boat Equipment › Paddle/Oar
Issued 9 April 2009 Resolved
Provide proper oars for aft rescue boat IAW 46 CFR 175(a) (20), current oars are in poor condition and unlabeled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 27 May 2009
Resolution: Proper oars provided.
Engineering › Lubricating Oil Service System › Piping
Issued 22 January 2009 Resolved
Properly repair hydraulic leak on fwd elevator hydraulic supply line iaw 46 CFR 58.30 (a)(14).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2009
Resolved 26 February 2009
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 22 January 2009 Resolved
Properly install all penetrations throughout vessel per NVIC 9-97 section 3.13.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 February 2009
Resolved 26 February 2009
Personnel › Training › Fire Fighting Basic
Issued 22 January 2009 Resolved
Properly train all persons assigned as PSP's on the station bill and provide means to conspicuously mark their uniforms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2009
Resolved 26 February 2009
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 October 2008 Resolved
Prove proper operation of the following FSD's 2, 4,5,6, 21,27.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 5 December 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 October 2008 Resolved
Provide First Aid training to include CPR for all members of the Marine Crew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 5 December 2008
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 6 October 2008 Resolved
Remove all plastic trash cans throughout the vessel including self-serve bars.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 5 December 2008
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 6 October 2008 Resolved
Prove proper operation of No. 1 Generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 5 December 2008
Lifesaving › Rescue Boat › Propulsion Engine
Issued 6 October 2008 Resolved
Prove proper operation of the Aft rescue boat.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 5 December 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 6 October 2008 Resolved
Create a Lifesaving mantenance log per 46 CFR 199.190
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 5 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2008 Resolved
Remove all daisy chained electircal cords in [name withheld] and Cindy Thompsons office.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2008
Resolved 5 December 2008
Engineering › Steam System (auxiliary) › Piping Drain
Issued 17 July 2008 Resolved
During this inspection the #3 boiler low cut out switch was not tested due to boiler no being in operation. Test at 4th qtr inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2008
Resolved 13 November 2008
Resolution: Received letter from chief eng requesting to place #3 boiler out of service until further notice.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 July 2008 Resolved
Prove proper operation of SFSD No. 6, and FSD's No. 2,6,15,27.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 August 2008
Resolved 10 October 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 July 2008 Resolved
Provide sufficient receptacles in the Pilothouse to accommodate electrical demands of office equipment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2008
Resolved 29 August 2008
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 17 July 2008 Resolved
Provide panel directory for panel panel EP 411.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2008
Resolved 29 August 2008
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 17 July 2008 Resolved
Determine Cause and currect overcurrent protection device labeled Breaker No. 29 in panel LP 228.
Condition: Unknown
Due 17 August 2008
Resolved 29 August 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 April 2008 Resolved
Renew fire control plan, post as required, and submit approved copy to OCMI.
Due 11 May 2008
Resolved 17 August 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 April 2008 Resolved
Demonstrate proper operation of FSD #8 (Stbd aft) wrt pressure of system and time of closure.
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 11 April 2008
Fire Fighting › Ventilation Systems › Operating Controls
Issued 11 April 2008 Resolved
Demonstrate proper operation of fire damper overide panels, main deck service halls.
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 17 July 2008
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 7 January 2008 Resolved
Determine source of ground fault and take corrective action in Phase B of the emergency generating circuit.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 17 July 2008
Resolution: Ground fault detector tested all sat.
Fire Fighting › Fire Hoses › Location
Issued 7 January 2008 Resolved
Provide/install access port in high stakes poker divider wall, port/fwd/entry for hose station #10 access to poker room.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 11 April 2008
Resolution: withdrawn- hose successfully passed over half wall and able to reach space.
Engineering › Steam Boiler (auxiliary/waste heat) › Furnace
Issued 16 November 2007 Resolved
Submit a repair proposal for auxiliary boiler #2, discovered leaking tube sheet during hydrostatic test, plate wastage that separates the furnace first pass from final pass and lagging hanging down.
Action required: 705 - Other - as specified
Due 16 December 2007
Resolved 7 January 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 October 2007 Resolved
Add emergency lighting in outboard section of VIP cardroom.
Due 7 November 2007
Resolved 16 November 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 October 2007 Resolved
Properly label emergency lights in VIP card room heads.
Due 7 November 2007
Resolved 16 November 2007
Fire Fighting › Structural - Main Vertical Zones › General
Issued 15 October 2007 Resolved
Adjust pocket doors in stbd/aft and port/fwd fire screen doors, Casino Deck.
Due 7 November 2007
Resolved 16 November 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 15 October 2007 Resolved
Remove excess flammables/combustibles from Housekeeping office.
Due 7 November 2007
Resolved 16 November 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 October 2007 Resolved
Properly service portable fire extinguisher (dry chem) located in Surveillance room.
Due 7 November 2007
Resolved 16 November 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 15 October 2007 Resolved
Properly replace cracked glass for CO2 pull station to Emergency Generator space.
Due 7 November 2007
Resolved 16 November 2007
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 15 October 2007 Resolved
Demonstrate compliance with 33 CFR 164.30 and 164.35, as amended by 46 CFR 77.
Due 7 November 2007
Resolved 15 November 2007
Resolution: Vsl requested and recd waiver from the reqts of both due to dockside operation only clause.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 July 2007 Resolved
Install Panel directories in panels EP-207 and SP-230.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 17 August 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 July 2007 Resolved
Prove proper operation of FSD-12. Door would not close and latch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 17 August 2007
Communications › Alarms/Indicators › Fire Alarm
Issued 18 July 2007 Resolved
Clear all faults on main fire alarm panel IAW 46 CFR 76.33-20
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 17 August 2007
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 18 July 2007 Resolved
Prove proper operation of Aux steam boiler No. 3 low water cut out audiable alarm and visual indicator IAW 46 CFR 63.17-7.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 17 August 2007
Engineering › Lubricating Oil Service System › Gauge
Issued 11 January 2007 Resolved
Verify lube oil low pressure alarm and shutdown set points are set in accordance with manufactures specification and 46 CFR 61.40-6.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 13 April 2007
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 10 January 2007 Resolved
Properly replace cracked jacket water return hose from jacket water heater on port side of #1 Ship Service Diesel Generator.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 16 February 2007
Engineering › Fuel Oil Service System › Piping
Issued 10 January 2007 Resolved
Provide plan to properly install fuel oil cooler on #1 Ship Service Diesel Generator, found cooler was removed before inspection for repairs, in accordance with manufactures specification and 46 CFR 58.10-10.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 16 February 2007
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 10 January 2007 Resolved
Determine reason for trouble alarm discovered on the sprinkler panel in the pilot house.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 16 February 2007
Fire Fighting › Structural - Main Vertical Zones › General
Issued 10 January 2007 Resolved
Properly adjust fire screen door #6 and all double doors.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 13 April 2007
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 23 October 2006 Resolved
Remove all combustable materials being stored in the future Casino space, or conduct fire load calculations and submit for approval plans to re designate space as a storeroom per 46 CFR 72.05 and NVIC 9-97, Max load permited is 3lbs per sq. ft.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 December 2006
Resolved 15 December 2006
Resolution: Future casino place cleaned out of excess combustible material.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 October 2006 Resolved
Remove velcro covers from all fire screen doors, and prove proper operation of Doors 1 and 2 per 46 CFR 72.08-25. Doors have failed multiple times due to design of velcro covers on door pockets. O/O must remove all velcro to clear this requirement.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 December 2006
Resolved 15 December 2006
Resolution: Witnessed proper operation of FSDs # 1 and 2. Velcro covers were still in place but some Velcro had been moved to allow the doors to open.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 23 October 2006 Resolved
Refill Emergency escape breathing devices in the Control Booth.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2006
Resolved 15 December 2006
Resolution: Check EDBs in control booth. All pressures sat.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 23 October 2006 Resolved
Place both Rescue boat davits on the vessels emergency bus per 46 CFR 112.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2006
Resolved 15 December 2006
Resolution: Davits connected to emergency bus panel 21EP208.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 October 2006 Resolved
Prove proper operation of the emergency light located near Fire screen door number 30.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2006
Resolved 15 December 2006
Resolution: Witnessed proper operation of emergency light located neat FSD #30.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 October 2006 Resolved
Prove proper operation of FSD's 9, 10, 18, 27.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2006
Resolved 15 December 2006
Resolution: Witnesssed proper operation of doors # 9,10, 18, and 27.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 23 October 2006 Resolved
Prove proper operation of the Emergency Gen alarms.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2006
Resolved 15 December 2006
Resolution: Required e-gen alarms tested. All sat.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 19 July 2006 Resolved
Properly adjust or replace boiler # 1 and #2 pressure relief valves in accordance with 46 CFR 54.15-10. Two valves when properly tested were set to high.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 6 September 2006
Engineering › Diesel Engine (propulsion-electric) › Crankcase
Issued 19 July 2006 Resolved
Properly make repairs to stop small oil leak discovered on fitting line to oil pre lube pump on SSDG # 2 and # 3.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 6 September 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 19 July 2006 Resolved
Submit test procedures to MSC and certification report for each automatic auxiliary boiler in accordance with 46 CFR 63.10-1.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 13 April 2007
Fire Fighting › Structural - Main Vertical Zones › General
Issued 19 July 2006 Resolved
Prove proper operation of Fire Screen Door # 6 in accordance with 46 CFR 72.05.
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 15 December 2006
Resolution: Witnessed proper operation of FSD #6.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2006 Resolved
Properly end dead end wires in a junction box or remove wires in accordance with 46 CFR 111.60-17.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 April 2006 Resolved
Provide a seal to opens in the boiler # 1 control panel and remote shutdown panel located at the top of the stairwell stbd side.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2006 Resolved
Discovered dead end wiring on top of auxiliary pump used to pump out #3 condensate blow down tank. Properly repair float switch for # 3 boiler blowdown tank.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 19 April 2006 Resolved
Provide on board approved periodic safety testing procedures in accordance with 46 CFR 61.40-6.
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 19 July 2006
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 19 April 2006 Resolved
Properly remove ground reading on EP200A, LP200B, and LP200A circuits in accordance with 46 CFR 111.30
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 19 April 2006 Resolved
Properly test jacket water alarm and shutdown for SSDG # 2 in accordance with 46 CFR 110.10.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 19 April 2006 Resolved
Properly repair fuel oil cooler on # 2 SSDG in accordance with 46 CFR 110.10.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 19 April 2006 Resolved
Properly replace cracked glass on remote pull station for CO2 system.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 19 April 2006 Resolved
Provide flammable storage locker for aerosol cans located throughout the vessel or remove aerosol cans in accordance with 46 CFR 72.03-5.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 17 May 2006

Casualty record · 2

31 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2581603
24 May 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2671349
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.