2510; The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety. During the inspection of the starboard lifeboat, the PSCO found a patch on the port quarter. The PSCO also found the limit switch is cracked. All ship's, See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Surveyor.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 17 January 2017
Resolved
2510; The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety. The ship's incinerator has a 7 cm crack in the upper left corner with a 4 cm drill stop that was never reported. The ship is missing a high temperature heat gun, See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Surveyor.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 January 2017
Resolved
0371; The machinery and associated piping system and fittings shall be adequate for the service for which they are intended. Cargo hold hydraulic rams 1(p) aft ram, 2(s) forward ram, and 4(s) forward ram are all leaking oil. Cooling S/W pump is missing a safety guard. The educator for bilge/ballast has a 25 cm patch. The main engine air cooler discharge pipe is patched. 74 SOLAS(14) II-1/26
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Surveyor.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 17 January 2017
Resolved
2120: Every ship shall carry a Garbage Management Plan which the crew shall follow. The Garbage Plan is not being followed, mixed garbage was found throughout the ship. As well as excess garbage was being kept in the Bos'n store blocking the life saving equipment, MARPOL Annex V/10, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Superintendent.
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 17 January 2017
Resolved
2510: The spill mitigation requirement of 33CFR155.5035(c) must be met for non-tank vessels. Ship has 02 spill kits that were inspected 14 Jan 17 that have wasted sorbent material that would be non-usable in case of a spill, 33CFR151.26, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Discussed with the [name withheld] and Superintendent. These were additional items for spill response.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 17 January 2017
Resolved
2510: Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel currently is not following their Ballast Water Management Plan or the Bio-Fouling Plan. Crew was unable to fine IMO Resolution 868(20), 33CFR151.2050(g), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Superintendent.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 January 2017
Resolved
0999: Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position with the valve protection cap on. Vessel has un-bracketed bottles in the CO2 room and A/C room, 46CFR147.60(b), 10C.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Superintendent.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 January 2017
Resolved
0710: The prevention ignition of combustible materials or flammable liquids shall be restricted. Vessel had flammable items in their Engine Room Locker, Deck Room Locker and aft steering such as paint and kerosene, 74 SOLAS (14) II-2/4/1/4, 10C.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Superintendent.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 17 January 2017
Resolved
0371; Each enclosed space entry and rescue drill shall include checking and use of rescue equipment and procedures. The enclosed space stretcher has grommets missing and it is not of the appropriate size for all crew members. 74 SOLAS (14) III/19.3.6.2.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2017
Resolved 21 January 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Surveyor.