MAURY USCG vessel records Sign in
← All vessels

YC PANSY

YC PANSY is a 2005 tank ship. The Coast Guard has recorded 26 inspections since 2005, most recently in June 2025, along with 4 deficiencies and 3 operational controls.

Records from 2005 to 2025. Most recent: inspection, 16 June 2025.

Built
2005
Last inspected
16 June 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9311256 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
795958
Flag
REPUBLIC OF KOREA
—
Maury page id
psix-795958

Inspections, by type

…with no type recorded6
Years with a record 15 calendar years (2005–2025)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25978 - Displacement, Metric Ton
20645 - Dead Weight, Metric Ton
11642 - Convention (Subpart B), Gross Ton
6420 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

16 June 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8157227
5 June 2023 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7703884
12 April 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7663798
5 February 2022 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7391222
26 October 2021 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7340640
17 October 2021 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7329946
24 June 2021 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7234389
19 October 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7079829
9 October 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7071850
1 May 2019 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6669282
24 April 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6390427
23 April 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6397883
23 April 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6404591
17 June 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6178527
20 May 2017 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6152150
17 October 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6020425
20 August 2015 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5215847
24 May 2012 COC-CHEM Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4314194
4 May 2012 Administrative Inspection · ISPS II Exam · Ballast Water Examination · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4300146
23 February 2011 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3950835
2 January 2008 MARPOL Annex I Examination · COC-CHEM Renew · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3123781
14 April 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2905983
14 April 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2907903
4 April 2007 ISPS III Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2900122
28 October 2005 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2521079
28 October 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2524361

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 17 October 2021 Resolved
ALTERNATIVELY, PRESSURE SENSORS MAY BE FITTED IN EACH TANK PROTECTED BY THE ARRANGEMENT REQUIRED IN PARAGRAPH 6.1.2, WITH A MONITORING SYSTEM IN THE SHIP'S CARGO CONTROL ROOM OR THE POSITION FROM WHICH CARGO OPERATIONS ARE NORMALLY CARRIED OUT. SUCH MONITORING EQUIPMENT SHALL ALSO PROVIDE AN ALARM FACILITY WHICH IS ACTIVATED BY DETECTION OF OVER-PRESSURE OR UNDER-PRESSURE CONDITIONS WITHIN A TANK. PSCO OBSERVED LOW PRESSURE ALARM ON 4S TANK MALFUNCTIONING. CREW STATED ALARM IS FAULTY. (74 SOLAS (20) II-2/11.6.3.2) (16ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 February 2022
Resolved 5 February 2022
Resolution: Sector Houton PSC received class documention from agent of vessel stating all repairs has been completed as well as approved by class surveyor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 October 2020 Resolved
THE CENTER OF THE RING SHALL BE PLACED ADMIDSHIPS AND AT A DISTANCE EQUAL TO THE ASSIGNED SUMMER FREEBOARD. PSCO NOTED THE PLIMSOL MARK APPEARS TO BE NOT IN ACCORDANCE WITH THE CERTIFICATE.
Action required: 15 - Rectify deficiencies by next port
Due 9 October 2020
Resolved 20 October 2020
Resolution: PSC NOLA received a class report from ABS satisfying the requirement
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2020 Resolved
ELECTRICAL INSTALLATION SHALL BE SUCH THAT THE SAFETY OF THE CREW AND SHIPS FROM ELCTRICAL HAZARDS WILL BE ENSURED. PSCO DISCOVERED MULTIPLE SPLICED WIRES ON DECK WHERE LIGHTING FIXTURES WERE LOCATED ADMISHIPS CARGO DECK LIGHTS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2020
Resolved 20 October 2020
Resolution: PSC NOLA received a class report from ABS satisfying the requirement
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 24 May 2012 Resolved
2199-Other MARPOL operational defic. -After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the Administration. PSCO observed gray and black water system drains redirected to the ballast water holding tank within the engine room- 74 SOLAS 09cons I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 May 2012
Resolved 15 October 2012
Resolution: PSC NOLA received a class report from Nippon Kaiji Kyokai satisfying the requirement.

Ownership record