Records from 2005 to 2026. Most recent: inspection, 2 January 2026.
Documentation record
Registered dimensions (L × B × D)261.5 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 2,994 / net 1,148
ITC dimensions (L × B × D)261.5 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 2,994 / net 1,148
BuilderNORTH AMERICAN SHIPBUILDING LLC · LAROSE, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4759 - Dead Weight, Gross Ton
2994 - Convention (Subpart B), Gross Ton
1148 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
2 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8290426
14 November 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8034696
26 June 2024
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7943306
26 June 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8007856
6 October 2023
ACP Annual Oversight · Annual Inspection · ACP COI Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7801764
10 July 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7738852
30 July 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019898
25 April 2017
ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6042290
23 December 2015
Administrative Inspection · ISM Oversight · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5785986
18 March 2014
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4818202
7 February 2012
ACP Annual Oversight · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4228531
3 February 2011
MTSA/ISPS Verification · ACP COI Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3937742
19 February 2010
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3682094
19 December 2009
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3658214
17 December 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3909449
29 January 2009
ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3390754
23 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245423
17 February 2008
ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3147423
1 March 2007
ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2880774
20 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2804346
21 April 2005
Construction Oversight · ACP COI Oversight · MTSA/ISPS Verification · Welding Related Inspections Qualification Testing · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2340074
Lifesaving › Launching Appliances › Winch
Issued 4 April 2012
Resolved
Make permanent repairs to rescue boat davit control box enclosure (temp repairs installed to protect interior components from outside elements) & repair limit switch to prevent "two-blocking" of hoisting hook.
Due 5 May 2012
Resolved 1 June 2012
Resolution: Received ABS report which addresses this def.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 4 April 2012
Resolved
Replace breaker #8 on panel P-403 with a 30 amp breaker (currently 40 amp-breaker card states 30).
Due 5 May 2012
Resolved 1 June 2012
Resolution: Received ABS report which addresses this def.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 April 2012
Resolved
Complete all automation test per ABS approved manual (Feb 1, 2006)
Due 5 May 2012
Resolved 1 June 2012
Resolution: Received ABS report which addresses this def.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 April 2012
Resolved
Bridge steering alarm panel has no power. Prior to departure from anchorage provide third party report.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2012
Resolution: Vessel provided company electrician who trouble shot and corrected the problem as we were departing the vessel, tested satisfactory.
Communications › Alarms/Indicators › Fire Alarm
Issued 4 April 2012
Resolved
Fire detection panel shows multiple zone trouble alarms. VSL to implement hourly rounds of vessel until F.D. alarm panel is repaired. Submit third party tech report.
Due 5 May 2012
Resolved 1 June 2012
Resolution: Received ABS report which addresses this def.