MAURY USCG vessel records Sign in
← All vessels

ZEUGMAN

ZEUGMAN is a 2003 tank ship. The Coast Guard has recorded 7 inspections since 2005, most recently in May 2006, along with 4 deficiencies and 1 operational control.

Records from 2005 to 2006. Most recent: inspection, 9 May 2006.

Built
2003
Last inspected
9 May 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9259111 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
796610
Flag
TURKEY
—
Maury page id
psix-796610

Inspections, by type

…with no type recorded4
Years with a record 2 calendar years (2005–2006)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1612 - Regulatory (Subpart C or D), Net Ton
1612 - Convention (Subpart B), Net Ton
3646 - Regulatory (Subpart C or D), Gross Ton
3646 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

9 May 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2645084
5 May 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2641529
18 November 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2536940
14 November 2005 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2536540
9 November 2005 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2531395
9 November 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2541628
8 November 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2531347

Deficiency record · 4

Deck/Cargo › Cargo Stowage › General
Issued 9 November 2005 Resolved
Audible alarm from tank overfill out on cargo deck not operational.. Alarm line filled with water. Alarm line cleaned and working while on board
Action required: 705 - Other - as specified
Due 9 November 2005
Resolved 9 November 2005
Resolution: Corrected while on board
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 November 2005 Resolved
Fire door lower level engine room starboard side, for emergency escape not self closing. Make door self closing to satisfaction of class.
Action required: 705 - Other - as specified
Due 9 December 2005
Resolved 5 May 2006
Resolution: Received class report, cleared deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 November 2005 Resolved
Modifications have been made to the piping arrangements for oily water separator. Drawing # CT18-P-21 dated 28Aug05. Administration to approve the changes prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2005
Resolution: Class examined piping arrangement and modifications to be removed by till 10 January 2006.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 9 November 2005 Resolved
With modifications made to oily water separator piping, provide a copy or report made to managers informing them of this modification prior to departure and provide managers return response.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2005
Resolution: Received report from managers.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.