Records from 2016 to 2026. Most recent: inspection, 15 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 31
15 May 2026
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8370724
11 May 2026
COE-Administrative
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8371059
2 July 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8170123
4 November 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029131
22 October 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8020619
27 September 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8007542
8 September 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7996955
28 June 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7941858
21 March 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7882984
13 February 2024
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7861525
30 March 2023
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7656090
30 August 2022
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7546595
26 August 2022
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7544316
12 August 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7527755
12 April 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7429340
29 January 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7387574
10 May 2021
PSC B · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7188730
5 November 2020
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7088398
21 October 2020
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7077991
23 February 2020
PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6911739
16 January 2020
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6884931
13 December 2019
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6869479
13 December 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6873359
25 April 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6675908
28 February 2019
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6634015
2 July 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458522
21 October 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6292241
25 July 2017
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6220151
28 June 2017
ISPS II Exam · COE-Dockside · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6184202
25 October 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6026182
21 July 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5948140
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 October 2024
Resolved
Every ship which does not carry a doctor shall be provided with an approved medicine chest with readily understandable instructions. PSCO observed expired OTC medication in medicine chest.
46 USC 70002
ILO-147 p38/26
Action required: 15 - Rectify deficiencies by next port
Resolved 23 October 2024
Resolution: Received invoices for new medication.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 22 October 2024
Resolved
Where penetrations of watertight bulkheads are necessary for access, piping, ventilation are to be made to maintain the the watertight integrity. PSCO observed wasted ventilation pipe in battery room.
74 SOLAS (2001) II-1/25-9.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 November 2024
Resolution: Received class report attesting to satisfactory repair.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 8 September 2024
Resolved
The SMS should ensure the compliance with mandatory rules and regulations. Vessels fire detection system was determined to be faulty on 08AUG2024. No notifications to the RO, Bureau Veritas, the issuing authority of the Cargo Ship Safety Construction certificate were made.
74 SOLAS (20) IX/3
ISM code 1.2.3.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2024
Resolved 9 September 2024
Resolution: Vessel provided Flag and Class reports. Class issued conditions for all 03 defs for 45 days, 25OCT2024. Def's cleared, refer to document tab for further information.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 September 2024
Resolved
Any required fixed fire detection & fire alarm system with manually operated call points shall be capable of immediate operations at all times. PSCOs found faulty fire detection in fire zones 4 & 6. rendering alarms inactive.
74 SOLAS(01)
II-2/13.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2024
Resolved 9 September 2024
Resolution: Vessel provided Class report. Class issued conditions for def for 45 days, 25OCT2024. Def cleared, refer to document tab for further information.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 8 September 2024
Resolved
Each survival craft shall be stowed in a state of continuous readiness so that two crew members can carry out preparations for embarkation & launching in less than 5 min. PSCOs determined the vessel has no means to secure embarkation for port & starboard aft life rafts & FWD port life raft.
74 SOLAS (20)
III/13.1.3
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 September 2024
Resolved 9 September 2024
Resolution: Vessel provided Class report. Class issued conditions for def for 45 days, 25OCT2024. Def cleared, refer to document tab for further information.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 June 2024
Resolved
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the main source of electrical power supply. PSCO observed non-approved battery charger for emergency generator.
SOLAS (Cons 04) II-1/43.3.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2024
Resolved 29 June 2024
Resolution: Rec'd proper documentation from vessel for replacement charger. BV Class Surveyor attended. Class report attesting to repairs accepted.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 June 2024
Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily servce tank, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occuring in a space in which such tanks are situated. PSCO observed zone 2 fuel shut off valves in engine room were inoperable.
SOLAS (Cons 01) II-2/15.2.5
Action required: 10 - Deficiency Rectified
Due 28 June 2024
Resolved 28 June 2024
Resolution: PSCO witnessed satisfactory closure of zone 2 fuel shut off valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 May 2021
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements. PSCO found a temporary patch on the engine housing of auxiliary generator #1, not approved by class. 74 SOLAS (2004) CH II-1, Part A-1, Reg. 3-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 20 May 2021
Resolution: Class Dispensation Issued until 20JAN2022 for next dry dock.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 10 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present conventions. Vessel does not have proper bottle brush per OWS manufacturer specifications for weekly testing. MARPOL 73/78 Annex I, Reg 6, 4.1
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 20 May 2021
Resolution: Bottle brush purchased by company.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 May 2021
Resolved
Where penetrations of watertight bulkheads and internal decks are necessary for piping, arrangements are to be made to maintain the watertight integrity. Cap on sounding tube on stbd fuel oil bunker tank was replaced to PSCO satisfaction. 74 SOLAS (2001) Ch II-1, Reg 25-9.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Replaced cap on sounding tube.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 May 2021
Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the Code. Hydrostatic release unit didn't have proper expiration date and serial no. didn't match maintenance certification. 74 SOLAS (2014) III/34. LSA Code 4.1.6.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Replaced HRU.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 October 2020
Resolved
Ship shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical tequirements. PSCO found a temporary patch on the engine house of the auxillary generator.
74SOLAS(2004 Cons) II-1, Part A-1, Reg 3-1
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2020
Resolved 21 October 2020
Resolution: Recieved satisfactory class report from BV
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 January 2020
Resolved
General Arrangement Plans shall be permanently exhibited for guidance of the ship's officers showing clearly for each deck the control stations and the various fire sections enclosed by "A" Class division. In accordance with the vessel's fire control plan, the stairway to the bridge was required to have "A" boundaries. The Port State Control officer observed a door in this stairway not closing properly and failing to maintain the "A" boundary.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 January 2020
Resolved 23 February 2020
Resolution: Witnessed satisfactory test of door.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 13 December 2019
Resolved
IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED NUMEROUS AND EXCESSIVE FUEL LEAKS FROM MAIN ENGINE CONSTITUTING AN ONGOING, IMMEDIATE, AND EXTREME FIRE HAZARD. 74SOLAS(2001 Cons ed.) II-2/15.2
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 14 December 2019
Resolved 16 December 2019
Resolution: Observed proper operation of ship's engine and its associated fuel systems located on top.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 13 December 2019
Resolved
WHERE THERE ARE CLEAR GROUNDS FOR BELIEVING THAT THE MASTER OR THE CREW ARE NOT FAMILIAR WITH ESSENTIAL SHIPBOARD PROCEDURES RELATING TO THE PREVENTION OF POLLUTION BY OIL. PSCO OBSERVED 3.37 CUBIC METERS OF OIL UNACCOUNTED FOR AND ADDITIONALLY FOUND FUEL TRANSFER BETWEEN TANKS HAD BEEN LOGGED USING INCORRECT CODES BY EVERY ENGINEER WHO HAS SERVED ONBOARD FOR AT LEAST THE PAST YEAR. MARPOL 2017 Cons Annex 1/11.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2019
Resolved 16 December 2019
Resolution: Received Class Report from BV attesting to the correction of this deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 13 December 2019
Resolved
OIL RECORD BOOK SHOULD BE COMPLETED ON EACH OCCASION, ON A TANK
TO TANK BASIS IF APPROPRIATE, WHENEVER ANY OF THE FOLLOWING MACHINERY OPERATIONS TAKES PLACE IN THE SHIP; COLLECTION AND
DISPOSAL OF OIL RESIDUES. PSCO OBSERVED 3.37 CUBIC METERS OF OIL UNACCOUNTED FOR. MARPOL 2017 Cons ed. Annex 1 Reg 17/2.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2019
Resolved 16 December 2019
Resolution: Received Class Report from BV attesting to the correction of this deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 July 2018
Resolved
1420 – (Cleanliness of engine room) - The condition of the ship and its equipment shall be maintained after survey to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The PSCO observed main fuel line on MDE had a fuel oil leak dripping at a constant rate. – SOLAS 1974 (2001 Cons) Chapt. I, Reg. 11 (a) 60a
Action required: 60 - Rectify deficiencies prior to movement
Due 2 July 2018
Resolved 5 July 2018
Resolution: Received Class report attesting to fuel leaks being repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 July 2018
Resolved
0620 – (Inflatable liferafts) – Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that starboard liferaft painter line was in poor material condition. – SOLAS 1974 (2014 Cons) Chapt. III, Reg. 20 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2018
Resolved 5 July 2018
Resolution: Received class report attesting to duct tape as a temporary repair for painter line.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 2 July 2018
Resolved
1675 – (Ships Radar Transponder) – Every ship shall be provided with a search and rescue locating device capable of operating either in the 9GHz band or an frequencies dedicated for AIS. PSCO observed that the batteries for both search and radar transponders on board expired on May 2018. – SOLAS 1974 (2014 Cons) Chapt. IV, Reg. 7.1.3 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2018
Resolved 5 July 2018
Resolution: PSC NOLA received class report attesting battery expiration as JUL2018
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 July 2018
Resolved
0750 – (Fire prevention) – The fire resistance of the doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. PSCO observed that all fire resistant doors in the accommodation stairwell had no gasket material with air gaps at the bottom allowing light to protrude. – SOLAS 1974 (2001 Cons) Chapt. II-2, Reg. 47 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2018
Resolved 5 July 2018
Resolution: PSC NOLA received class report from BV stating fire boundaries/fire doors are not required to be air/gas tight
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2018
Resolved
9900 – (Other (not clearly hazardous) ) – The termination of the sounding pipes are fitted with self-closing blanking devices and with a small-diameter self-closing control cock located below the blanking device for the purpose of ascertaining before the blanking device is opened that oil fuel is not present. Provision shall be made so as to ensure that any spillage of oil fuel through the control cock involves no ignition hazard. PSCO observed DOT missing self-closing device weight. Sludge oil and bilge water collecting tank devices would not self-close. – SOLAS 1974 (2001 Cons) Chapt. II-2, Reg. 15.6.1.3 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2018
Resolved 5 July 2018
Resolution: PSC NOLA received a class report from BV stating sounding tubes were corrected.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 2 July 2018
Resolved
1710 – (Oil Record Book) – Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation re completed. PSCO observed multiple entries in the ORB that list discharge of sludge and DOT not using proper codes. Provide corrective action plan with concurrence of Administration.. – MARPOL (2011 Cons. Ed.) Annex I, Reg. 17.4 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2018
Resolved 5 July 2018
Resolution: PSC NOLA received class report from BV stating ORB was corrected and training was preformed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 July 2018
Resolved
0715 – (Detection) – The following fire protection system shall be kept in good order so as to ensure their required performance if a fire occurs; fire detection and alarm systems. PSCO observed a smoke detector covered in the fuel oil purifier room. – SOLAS 1974 (2014 Cons) Chapt. II-2, Reg. 14.2.1 10c
Action required: 10 - Deficiency Rectified
Due 2 July 2018
Resolved 2 July 2018
Resolution: PSCO had ship engineers remove the cover from the smoke detector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2018
Resolved
9900 – (Other (not clearly hazardous) ) – Each ANOA must contain all of the information items specified in Table 106.206. PSCO observed that the Nationality of the vessel’s Master was provided incorrectly on the ANOA. – 33CFR Part 260.206(a)(4)(iii) 10c
Action required: 10 - Deficiency Rectified
Due 2 July 2018
Resolved 2 July 2018
Resolution: PSCO had Master update the vessel's ANOA to reflect his correct Nationality.
Construction/Loadline › Hull › Hull Plating
Issued 28 June 2017
Resolved
PSCOs noticed two large dents in hull of starboard quarter that were not addressed during last hull survey. Cite: SOLAS(14) I/11(a); 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2017
Resolved 24 July 2017
Resolution: Received letter from class
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 June 2017
Resolved
The crew was not ale to provide a proper test of the OWS. The valves were found to be rusted & could not provide efluent to the system. MARPOL Annex 1 Reg. 14.1; 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2017
Resolved 24 July 2017
Resolution: Received letter from class