Records in 2005. Most recent: inspection, 14 December 2005.
Documentation record
Tonnage as PSIX records it2982 - Regulatory (Subpart C or D), Net Ton
2982 - Convention (Subpart B), Net Ton
358532 - Dead Weight, Ton
9999 - Regulatory (Subpart C or D), Gross Ton
9999 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
14 December 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2551397
7 December 2005
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2547624
11 November 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2546209
7 November 2005
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2529795
7 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2530066
6 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2529341
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 November 2005
Resolved
Sea water cooling line holed. Lower level Engineroom port side frame 55. Make repairs to satisfaction of class before departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2005
Resolved 8 November 2005
Resolution: A 2 meter section of the piping was renewed and tested under pressure as per Class.
Engineering › Steering Gear System › Piping
Issued 7 November 2005
Resolved
Remove the excessive oil on the decks in both steering spaces. corrected on the spot.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 7 November 2005
Resolution: Cleaned by ships personnel prior to departure of inspector.
Engineering › Steering Gear System › Piping
Issued 7 November 2005
Resolved
Starboard steering gear is leaking excessively. Class to examine the starboard steering gear prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2005
Resolved 8 November 2005
Resolution: Steering gear cleaned and inspected one o-ring replaced as per Class report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 7 November 2005
Resolved
CO2 bottles just throw into store room car deck port side frame 145. Properly store CO2 bottles , to satisfaction of class.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 8 November 2005
Resolution: Expired portable fire extinguisher bottles are now secured properly as per Class report.
Fire Fighting › Structural - Horizontal Zones › General
Issued 7 November 2005
Resolved
Structural fire insulation missing in the overhead of the engineroom, engineroom platform deck port side between frames 35-26.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 7 December 2005
Resolution: Received Class report that insulation not need as per SOLAS 74
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 7 November 2005
No resolution recorded
General alarm/fire alarm bell located outside on aft bulkhead of pilot house is not operating. Prove proper operation to satisfaction of class.
Action required: 705 - Other - as specified
Due 7 December 2005 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 November 2005
Resolved
Sensor on port sewage holding tank leaking, repair leak, corrected while on board.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 7 November 2005
Resolution: leaked repair prior to Marine Inspectors departure.