Records from 2016 to 2026. Most recent: inspection, 14 January 2026.
Inspection history · 25
14 January 2026
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8290070
12 January 2026
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8303431
3 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8075759
8 April 2024
Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7891540
9 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7942707
10 August 2023
Examination of Repairs · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7778691
5 April 2023
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7663032
14 March 2023
In-Service Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7650778
8 May 2022
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7447006
6 April 2022
Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7425559
13 January 2022
Examination of Repairs · In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7379726
19 January 2021
Examination of Repairs · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7126549
2 November 2020
Damage Survey · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7088343
2 November 2020
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7089078
30 October 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7089018
22 April 2020
Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6942752
9 January 2020
Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6886242
30 October 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6845276
4 March 2019
Deficiency Check · Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6635723
27 August 2018
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6562983
26 April 2018
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6399086
11 January 2018
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6585048
2 October 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293386
26 January 2017
Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6110402
27 January 2016
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5844586
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 January 2026
Resolved
Replace 02 Adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 January 2026
Resolved
Replace 01 child life jacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2026
Resolved
Remove wire nuts in PORT side bench of salon.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2025
Resolved
Renew retro tape on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 8 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2025
Resolved
Raw water hose on STBD engine has small leak and needs to be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 8 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 April 2025
Resolved
2 different types of life jackets on board require two different donning placards
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 8 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2025
Resolved
Pump room high water alarm does not have both audible and visual alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 8 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2024
Resolved
Front two life floats needs repairs and repainting. Make repairs and repaint to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 6 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 April 2024
Resolved
Bridge port side weather tight door has a hole cut out for the exhaust of a portable a/c unit making the door non weather tight and inpeeds opening and closing the door during an emergency. Must remove a/c exhaust and replace door panel back to original design.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 6 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2023
Resolved
Anchor light was not working. Must make repairs and test to satisfaction of attending Marine Inspector. Vessel limited to daylight hours only.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2023
Resolved 18 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2023
Resolved
SSDG was found torn apart while conducting a spot check of vessel. Once repairs are completed, must conduct load test to the satisfaction of attending Coast Guard Marine inspectors. Vessel is limited to 49 passengers and must have minimum 3 fire buckets on-board until cleared.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 4 April 2023
Resolution: New SSDG installed and tested SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2023
Resolved
While conducting a spot check on vessel, found PVC piping is used for bilge/fire main piping in the engine room with duck tape on all joints. Piping used in a vital system must composed of ferrous materials except on aluminum hull vessels, vital system piping can be aluminum pipe. Must replace all PVC piping with aluminum pipe.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 19 September 2023
Resolution: Metallic piping installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 May 2022
Resolved
Window on STBD side was broken during vessel colision. Must make permanent repairs to the satisfaction of attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 17 May 2022
Resolution: Installed new window
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 April 2022
Resolved
As per your request, CG will allow you to operate without your fire pump working and add 3 fire buckets in accordance with regulations. Your passenger count will be limited to 49 passengers max until the fire pump issue has been resolved and cleared by CG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 May 2022
Resolution: Tested fire pump after repairs, test SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 April 2022
Resolved
Fire pump would only put out approx 38 psi. Requirement is 60 psi at discharge side of pump. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2022
Resolution: rebuilt old pump and replaced motor with new
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 February 2021
Resolved
Fire pump will only reach 44 psi max and slowly drops below 40 psi after 2 mins of running. Must make repairs to pump or replace to meet 60 psi and 50 gallons per min as required to satisfaction of attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2021
Resolved 4 February 2021
Resolution: cleaned and rebuilt pump, test with 70 psi. Test SAT
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 January 2021
Resolved
Outdated paper charts with no corrections were found and the Garmin GPS software version was 15.0. Current software version for that model was 21.0. Must update Garmin software or buy new approved paper NAV chart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 2 February 2021
Resolution: Bought new paper chart
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 January 2021
Resolved
Log for fire drills has little info. Must start logging all required info for fire drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 26 March 2021
Resolution: Made new log for drills
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 January 2021
Resolved
Missing Crew Training Log. Must start logging crew training as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 26 March 2021
Resolution: Made new log for new hire's
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 19 January 2021
Resolved
Compass light not working. Vessel restricted to daylight hours only until light is fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 26 March 2021
Resolution: Replaced light, test SAT
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 January 2021
Resolved
Fire pump discharge gauge not working. Must fix or replace gauge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 4 February 2021
Resolution: replaced guage, tested with 70 psi. Test SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2021
Resolved
A lot of wiring is hanging loose and mounted with plastic zip ties. Wiring must have a metal support no more than 24 inches apart. Go through all wiring throughout the boat and add metal supports as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 26 March 2021
Resolution: IAW ABYS rules, metal brackets were used over machinery
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2021
Resolved
Electrical junction box middle of engineroom broke off mount and is hanging by electrical wire. Must fix or replace junction box and mount properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 2 February 2021
Resolution: Fixed junction box and re attached to bracket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2021
Resolved
Two condensate pumps were added in engineroom and powered by extension cords. Must remove extension cords and hard wire pumps in.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 2 February 2021
Resolution: Both condensate pumps were hard wired, each one into each A/C units.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2021
Resolved
2 electrical boxes in engineroom have exposed wires and connections. Must fix or replace electrical boxes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 2 February 2021
Resolution: Covers were added to both electrical boxes
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 January 2021
Resolved
Machinery guards were missing on both MDE's and on a small electrical bilge pump. Must replace missing guards on BMDE's and fabricate a guard for the bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 2 February 2021
Resolution: Guards were placed on front of BMDE's and bilge pump
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2021
Resolved
Found a few dead in wires hanging lose in the engineroom. Must pull out any unused wiring or make proper connections inside junction boxes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 2 February 2021
Resolution: Deadend wires were pulled
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 January 2021
Resolved
Alcohol swabs had expired. Must replace with enough to test entire crew if something were to happen.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 2 February 2021
Resolution: New swabs were ordered and onboard
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 January 2021
Resolved
Several buckets of oil are being stored in the engineroom. Trays or small containers with no lids have little oil in them. Funnels with oil on them sitting in trays down in the bilge. Must pull all hazardous material out of the engineroom and store in a approved hazardous locker or store somewhere off the boat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 2 February 2021
Resolution: excess oil was pulled out of engineroom
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 January 2021
Resolved
Port MDE was found with an exhaust leak at the turbo flange. Must make repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 4 February 2021
Resolution: Replaced gasket, test SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 January 2021
Resolved
Weather tight door on main deck FWD cabin is rotted out by the handle. Need to replace door with same in kind.
**update** Vessel is having to order a new door and manufacture is running behind making new door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 28 January 2022
Resolution: Watertight door/frame was delivered last week and installed. Completed NDT on welds and water test on door seal. Tests SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 January 2021
Resolved
Stern light was not working. Must fix prior to carrying passengers.
COLREGS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2021
Resolved 20 January 2021
Resolution: Crew replaced bulb and tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2020
Resolved
The vessel has 04 red flares, and requirement is 06. Provide 2 new red flares
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2020
Resolution: 02 new red flares were purchased and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 April 2020
Resolved
Life ring on top deck need new line, and new lanyard clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2020
Resolution: Life ring line and lanyard clip were purchased and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 April 2020
Resolved
Forward starboard side life float has damage, repair or renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2020
Resolution: Life float damage was repaired, and verified.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2020
Resolved
Provide a log for monthly EPIRB & Life Saving Systems Maintenance.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2020
Resolution: Log for EPIRB and lifesaving system maintenance was created.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2019
Resolved
Forward compartment bilge suction is missing strainer, and is partially clogged. Provide new strainer, and repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Piping was renewed and a new strainer was installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 March 2019
Resolved
VHF must be linked to GPS, and have MMSI# input, or new VHF installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: New GPS ready VHF radio was installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 26 April 2018
Resolved
Provide proof of hydrostatic testing of fixed fire fighting cylinder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: Vessel provided documentation stating that cylinders were inspected IAW with NFPA 2001 and CGA-C6
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 April 2018
Resolved
Demonstrate proof of the automatic shut down of the generator in the engine room space upon activation of the fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: Demonstrated that pre-engineered fire suppression system will shut down all engine in the engine room upon discharge of system.
Fire Fighting › Fire Main › Condition
Issued 26 April 2018
Resolved
Provide proof of fire main system to maintain operational pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: Repaired ruptured pipe, demonstrated system operating at >60 psi.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 April 2018
Resolved
Mount all portable fire extinguishers to frame or support permanently mounted to a bulkhead or deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: Permanently mounted all portable fire extinguishers.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 April 2018
Resolved
Replace life ring buoy floating water light lanyard.
Action required: 705 - Other - as specified
Due 3 May 2018
Resolved 3 May 2018
Resolution: replaced.
Lifesaving › Lifefloat › Markings
Issued 26 April 2018
Resolved
Mark life float paddles with clearly legible name of vessel.
Action required: 705 - Other - as specified
Due 3 May 2018
Resolved 27 April 2018
Resolution: Properly marked life float paddles with vessel's name.
Fire Fighting › Fire Hydrants › Number
Issued 26 April 2018
Resolved
Provide spanner wrench for fire hose assembly.
Action required: 705 - Other - as specified
Due 3 May 2018
Resolved 3 May 2018
Resolution: Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2018
Resolved
Bearing in Stbd rudder tube has seized to the rudder post and turns with the rudder. Renew bearing.
Action required: 10 - Deficiency Rectified
Resolved 29 January 2018
Resolution: New rudder tube bearing was installed and tested all sat.
Lifesaving › Lifefloat › Painter
Issued 26 January 2017
Resolved
Painters on the life floats are watsted and must be replaced. Float lights were strapped to the sides of the life floats. They must be properly stowed.
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 9 February 2017
Resolution: New painter lines were installed and float lights were properly stowed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 January 2017
Resolved
PFD stowage is not marked with the correct numbers. Re-mark to match actual numbers.
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 9 February 2017
Resolution: Stowage was remarked.
Fire Fighting › Fire Hoses › Material
Issued 26 January 2017
Resolved
Fire hoses are not UL approved and are not ment for use on a boat. Provide proper hoses.
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 9 February 2017
Resolution: Proper hoses were provided, and tested.
Electrical › Electric Supply System (service) › Cable
Issued 26 January 2017
Resolved
2 extention cords are being used for perminent equipment. Remove the cords and wire with boat cable and j-box.
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 9 February 2017
Resolution: Extention cords were removed and replaced by properly run cables.