MAURY USCG vessel records Sign in
← All vessels

LISA

LISA is a 1957 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1988, most recently in April 2009, along with 74 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records from 1988 to 2009. Most recent: operational control imposed, 11 August 2009.

Built
1957
Last inspected
23 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE4488
Flag
UNITED STATES
367353890 (licence lapsed)
Maury page id
psix-79722

Inspections, by type

…with no type recorded3
…past their stated due date3
Years with a record 20 calendar years (1988–2009)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE4488MMSI 367353890 · expired · voluntarily equipped · granted 2 May 2008, cancelled 7 July 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCJ4020MMSI not assigned · expired · compulsorily equipped · granted 6 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 51

23 April 2009 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3459689
19 May 2008 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3180246
7 September 2005 Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2485305
9 February 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2289211
3 May 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2058071
22 May 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1799002
30 April 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1783834
8 February 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1485217
12 June 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379470
1 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373451
10 February 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1389009
14 June 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421666
12 April 1999 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 790063
3 February 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1472533
2 April 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 786755
25 February 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404531
26 March 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374913
11 February 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390440
30 January 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1449895
6 April 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 841455
20 March 1995 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 869515
2 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385398
24 October 1994 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440879
22 June 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387571
8 February 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164371
21 April 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1151773
25 March 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839202
2 February 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1145576
25 January 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1134570
19 November 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830263
31 January 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962136
10 April 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 918024
3 April 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900431
1 March 1991 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1211931
25 February 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220680
14 November 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929996
15 May 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1238541
16 March 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 922349
20 February 1990 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290071
6 February 1990 Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214414
20 November 1989 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 980931
17 September 1989 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1008122
16 August 1989 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1038986
15 April 1989 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1036788
17 March 1989 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342043
28 February 1989 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1199229
31 December 1988 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043971
30 November 1988 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1208072
23 November 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1196013
1 September 1988 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1194055
30 June 1988 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1347072

Deficiency record · 74

Construction/Loadline › Hull › Transverse Frame
Issued 11 August 2009 No resolution recorded
Renew wasted stbd frame below tail shaft from stbd shell to longitudinal frame outside of keel bilge. Gauge adjacent longitudinal frame inside keel bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2009 — due date passed with no resolution recorded
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 August 2009 No resolution recorded
Provide gauging reports for first watertight bulkhead fwd of transom on the suspect areas to include bubbling from chine to rub rail on the hull. Also gauge transom and make welds where transom fits up to side shell plating available for inspection.
Action required: 705 - Other - as specified
Due 11 August 2009 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Cable
Issued 23 April 2009 No resolution recorded
Replace wiring for water heater with proper marine installation IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 24 May 2009 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Piping
Issued 19 May 2008 Resolved
Provide metallic piping or hose for bilge system that meets J-1942.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2008
Resolved 27 June 2008
Resolution: Hose provided.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 May 2008 Resolved
Provide metallic piping or hose for SW cooling system for both main engines that meets J-1942.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2008
Resolved 27 June 2008
Resolution: Hose provided on both main engines.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 May 2008 Resolved
Provide metallic piping or hose for generator SW cooling system that meets J-1942.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2008
Resolved 27 June 2008
Resolution: Hose on generator provided.
Fire Fighting › Fire Bucket › Availability
Issued 19 May 2008 Resolved
provide a fire pump that meets 46CFR(Old "T") 181.10-5 or provide three fire buckets IAW 46CFR 181.610
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2008
Resolved 27 June 2008
Resolution: 3 Fire Buckets provided.
Electrical › Electric Supply System (service) › Cable
Issued 19 May 2008 Resolved
provide suitable wiring for light switch in closet IAW 46CFR183
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2008
Resolved 27 June 2008
Resolution: marine grade wiring and metal fasteners installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 May 2008 Resolved
Provide stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2008
Resolved 27 June 2008
Resolution: Bulb in stern light replaced.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005 Resolved
Provide proof of ABS plate certifications for the newly installed steel hull.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: Plate equivalent to ABS A36
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005 Resolved
Provide plate & internal structure material list for new hull installation.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: material list provided.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005 Resolved
Repair/replace 'all' steel inserts to minimum plate dimensions of 18" x 18".
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: undersize inserts correctly renewed with appropriate size
Construction/Loadline › Hull › Weld
Issued 7 September 2005 Resolved
Repair/weld all structural frames (side & bottom) to be welded intermittently 2" to 3" on center.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: frames welded as instructed
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 7 September 2005 Resolved
Replace cutlass, strut & carrier bearings on both port & stbd shafts due to wear.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: Bearings in process of renewal
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005 Resolved
Repair/replace (crop & renew) approx 10 sq/ft section of plate on the port forepeak.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: plate renewed
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005 Resolved
Repair/replace old portside overboard discharge line patch with 18" X 18" dimension steel insert.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: replaced
Construction/Loadline › Hull › Weld
Issued 7 September 2005 Resolved
Remove all slag for visual inspection of welds.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: all welds clean for visual exam
Construction/Loadline › Hull › Weld
Issued 7 September 2005 Resolved
Prepare welds for spot-checks by non-destructive dye testing.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: NDT schedule provided and spot checked
Construction/Loadline › Hull › Weld
Issued 7 September 2005 Resolved
Provide written plan for remodeling of the vsl's interior spaces, including above & below deck compartments.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Resolution: written plan presented
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005 Resolved
Submit light weight ship calculations to determine net steel weight replacement.
Action required: 705 - Other - as specified
Resolved 26 September 2005
Resolution: calculations submitted and reviewed.
Construction/Loadline › Hull › Hull Plating
Issued 9 February 2005 Resolved
Provide gauging report for deteriorated hull and side shell plating.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 26 September 2005
Resolution: gauging report provided. hull bottom plate replaced, wind & water strake max wastage <10%
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 February 2005 Resolved
Repair/replace deteriorated leaking integral steel fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 20 September 2005
Resolution: FO tank renewed, air test SAT
Engineering › Bilge Water Management System › Interface Detector
Issued 9 February 2005 Resolved
Provide bilge high level alarms for E/R and lazzarette
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 16 January 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 February 2005 Resolved
Replace deteriorated start batteries for main engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 16 January 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 February 2005 Resolved
Replace deteriorated start battery boxes in E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 16 January 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 February 2005 Resolved
Replace expired 1st aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 16 January 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 February 2005 Resolved
Repair leaky S/W suction piping to stbd main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 20 September 2005
Resolution: MDE R/W inlets renewed w/ sched 80 pipe
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 February 2005 Resolved
Insulate port main engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 16 January 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 February 2005 Resolved
Double hose clamp all S/W cooling hoses on port and stbd main engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 16 January 2009
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 February 2005 Resolved
provide cover for open receptacle in port cabin.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 16 January 2009
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Distributor (fuel injection)
Issued 3 May 2004 Resolved
Repair/make operational out of commision ship service generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2004
Resolved 9 February 2005
Resolution: corrected
Engineering › Sea-water System (primary cooling)
Issued 22 May 2003 Resolved
Crop and renew (3) deteriorating sea water suction inserts for both main engines and generator prior to receiving credit for drydock. LEGACY COMPONENT DESC: Sea Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2003
Resolution: Completed
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 May 2003 Resolved
Provide proof of maintenance/service to installed engineroom CO2 firefighting equipment, including hydrotesting, which was overdue at time of inspection. LEGACY COMPONENT DESC: Service Report
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2003
Resolved 29 May 2003
Resolution: CO2 bottle replaced, hydrotested, and system serviced. Witnessed service report.
Engineering › Bilge Water Management System
Issued 7 May 2003 Resolved
Prove proper operation of lazarette bilge ovbd valve (small independent electric pump). LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2003
Resolved 29 May 2003
Resolution: Valve replaced.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 7 May 2003 Resolved
Install smoke detector in area of berthing. LEGACY COMPONENT DESC: Smoke Alarms
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2003
Resolved 29 May 2003
Resolution: Smoke detector installed and tested.
Construction/Loadline
Issued 12 June 2001 Resolved
Submit gauging report on lazarrette space, bottom shell, where marked (between port and starboard rudder posts).
Condition: Unknown
Due 3 July 2001
Resolved 7 August 2001
Construction/Loadline
Issued 12 June 2001 Resolved
Crop and renew frames (side transverse) portside #4,5,12,13, IVO under-deckflooring (bilge space beneath galley).
Condition: Unknown
Due 3 July 2001
Resolved 7 August 2001
Construction/Loadline
Issued 12 June 2001 Resolved
Make watertight the bulkhead tween the forepeak and engineroom.
Condition: Unknown
Due 3 July 2001
Resolved 7 August 2001
Construction/Loadline
Issued 12 June 2001 Resolved
Renew welds on sideshell doubler, portside IVO frame #'s 12 and 13.
Condition: Unknown
Due 3 July 2001
Resolved 7 August 2001
Engineering
Issued 12 June 2001 Resolved
Replace portside forward shaft bearing.
Condition: Unknown
Due 3 July 2001
Resolved 7 August 2001
Construction/Loadline
Issued 12 June 2001 Resolved
Tighten rail footings on bow.
Condition: Unknown
Due 3 July 2001
Resolved 7 August 2001
Lifesaving
Issued 25 February 1998 Resolved
Ensure retroreflective tape is properly taped to lifefloat.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Accommodation/Occupational Safety
Issued 25 February 1998 Resolved
Properly install and mark emergency exit hatch on bow of vessel.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Lifesaving
Issued 25 February 1998 Resolved
Ensure lifefloat painter is connected to life float properly.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Navigation
Issued 25 February 1998 Resolved
Ensure proper operation of forward navigational light.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Engineering
Issued 25 February 1998 Resolved
Repair fuel vent screens with proper mesh.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Accommodation/Occupational Safety
Issued 25 February 1998 Resolved
Ensure proper operation of emergency exit door in accommodation space due to mattress is blocking doorway.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Lifesaving
Issued 25 February 1998 Resolved
Repair cracks in lifefloat properly.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Accommodation/Occupational Safety
Issued 25 February 1998 Resolved
Repair loose railing on vessel to original, both port and stbd sides.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Lifesaving
Issued 30 January 1996 Resolved
Total persons allowed is reduced by one (1) to fifty-two (52) until an approved personal flotation device (PFD) is provided.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Lifesaving
Issued 20 March 1995 Resolved
PROVIDE WEAK LINK FOR LIFE FLOAT.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Fire Fighting
Issued 8 February 1994 Resolved
PROVIDE 2 B-II EXTINGUISHERS.
Condition: Unknown
Due 9 February 1994
Resolved 13 February 1994
Construction/Loadline
Issued 8 February 1994 Resolved
PROVE PROPER OPERATION OF AFT LAZZARETTE BILGE PUMP.
Condition: Unknown
Due 9 February 1994
Resolved 13 February 1994
Construction/Loadline
Issued 8 February 1994 Resolved
REGASKET/MAKE WATERTIGHT GALLEY SPACE EXHAUST DUCT.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Documentation
Issued 8 February 1994 Resolved
PROVIDE COPY OF MARINE OPERATORS PERMIT. THIS MAY BE FAXED TO MSO SAN FRAN AT [phone withheld].
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Lifesaving
Issued 25 January 1993 Resolved
REPLACE LINE ATTACHING THE WATER LIGHT TO THE LIFE FLOAT. VSL IS RESTRICTEDFROM CARRYING PASSENGERS MORE THAN 1 MILE OFF SHORE.
Condition: Unknown
Due 25 February 1993
Resolved 25 March 1993
Electrical
Issued 25 January 1993 Resolved
PROVIDE PROPER LIGHT FIXTURE IN LAZARETTE.
Condition: Unknown
Due 25 February 1993
Resolved 25 March 1993
Documentation
Issued 25 January 1993 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 25 February 1993
Resolved 21 April 1993
Electrical
Issued 25 January 1993 Resolved
PROVE PROPER OPERATION OF, AND PROPERLY LABEL EMERGENCY LIGHTING SYSTEM.
Condition: Unknown
Due 25 February 1993
Resolved 25 March 1993
Engineering
Issued 25 January 1993 Resolved
REPLACE MISSING SCREW TO BELT GUARD ON ENGINE ROOM AUX GENERATOR.
Condition: Unknown
Due 25 February 1993
Resolved 25 March 1993
Documentation
Issued 25 January 1993 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION-VSL IS RESTRICTED FROM CARRYING PASSENGERS.
Condition: Unknown
Due 25 February 1993
Resolved 21 April 1993
Documentation
Issued 25 January 1993 Resolved
PROVIDE COPY OF "RULES OF THE ROAD"
Condition: Unknown
Due 25 February 1993
Resolved 25 March 1993
Lifesaving
Issued 19 November 1992 Resolved
PROVIDE MISSING PROTECTIVE LIGHT FIXTURES FOR ALL MISSING LIGHTING IN ENGINE ROOM.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Documentation
Issued 10 April 1991 Resolved
PROVIDE COPY WASTE MANAGEMENT PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Construction/Loadline
Issued 10 April 1991 Resolved
REPAIR/REPLACE PORT LIGHT WASH BASIN COMPARTMENT PORT BOW._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Construction/Loadline
Issued 10 April 1991 Resolved
LABEL PROPERLY INTERNALLY AND EXTERNALLY EMERGENCY ESCAPE HATCH FORWARD COMPARTMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Construction/Loadline
Issued 10 April 1991 Resolved
MODIFY COVER FOR FORWARD EMERGENCY ESCAPE TO EXPIDITE USE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Documentation
Issued 10 April 1991 Resolved
PROVIDE DOCUMENTATION OF ATTEMPT TO COMPLY WITH NEW DRUG TESTING PROGRAM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Engineering
Issued 10 April 1991 Resolved
REPLACE ALL FLAME SCREENS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Lifesaving
Issued 10 April 1991 Resolved
PROPERLY MARK STOWAGE OF LIFE PRESERVERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Navigation
Issued 10 April 1991 Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Engineering
Issued 6 February 1990 Resolved
INSTALL CHECK VALVES IN FORWARD AND ENGINE ROOM BILGE LINES IN ACCORDANCE WITH 46CFR182.25-5(C) AND AMMEND VESSELS PLANS ACCORDINGLY.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Fire Fighting
Issued 6 February 1990 Resolved
RECHARGE SINGLE B-II FIRE EXTINGUISHER(DRY CHEMICAL) PRIOR TO THE CARRIAGE OF PASSENGER FOR HIRE.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Fire Fighting
Issued 6 February 1990 Resolved
PROVIDE PLANS FOR FIXED CO2 SYSTEM IN ENGINE ROOM. PLANS SHOULD INCLUDE ACTIVATION METHODS, CYLINDER SIZE, PIPING SIZE AND MATERIAL, AND DISCHARGE OUTLET SIZE, NUMBER, AND MATERIALS.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990

Ownership record