JAG LALIT is a 2005 tank ship. The Coast Guard has recorded 5 inspections since 2017, most recently in September 2023, along with 1 deficiency and 1 operational control.
Records from 2017 to 2023. Most recent: inspection, 11 September 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it53774 - Convention (Subpart B), Net Ton 182623 - Displacement, Ton 158344 - Dead Weight, Ton 81396 - Regulatory (Subpart C or D), Gross Ton 53774 - Regulatory (Subpart C or D), Net Ton 81396 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
11 September 2023Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7789411
18 August 2023Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7771346
11 August 2023COC-TVE Renew · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7756570
5 August 2023Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7760909
27 January 2017Ballast Water Examination · ISPS II Exam · COC-TVE Renew · COE-Offshore
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6070421
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2023Resolved
The rating or appropriate setting of the overload protective device for each circuit shall be permanently indicated at the location of the protective device. The current protection for the systems listed below do not have an indicated circuit protection value or have a higher rated circuit protection installed. Located in ECR. LGSP-4, BWMS rectifier A, LGSP-5, LGSP-6, No.2 FWD deck machinery, BWMS rectifier B, and BWMS Motor control cabinet.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 18 August 2023
Resolved 5 September 2023
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National