Records from 2016 to 2026. Most recent: inspection, 17 May 2026.
Inspection history · 93
17 May 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8374688
13 April 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8346881
12 April 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8346404
5 April 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8343182
11 January 2026
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8295997
22 November 2025
PSC A · COC-CVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8248890
4 May 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8128154
5 April 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8105689
26 December 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8051031
15 December 2024
PSC A · COC-CVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8044656
1 December 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8041610
9 June 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7930194
29 May 2024
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7922714
15 March 2024
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7879785
3 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7844650
11 December 2023
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7836431
25 August 2023
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7773161
11 August 2023
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7764841
23 July 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7749622
12 June 2023
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7712746
12 May 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7686776
10 February 2023
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7631489
20 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7624608
3 January 2023
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7616383
12 December 2022
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7607963
18 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579552
13 June 2022
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7471210
9 May 2022
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7868636
11 March 2022
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7412242
16 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7381058
16 December 2021
Ballast Water Examination · COC-CVE Annual · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7363744
22 October 2021
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7337881
15 April 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7177902
7 January 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7120958
4 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935363
18 March 2020
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7112737
16 March 2020
PSC C
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6927251
6 March 2020
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6948018
24 February 2020
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6915134
7 February 2020
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6914622
9 January 2020
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6885852
6 December 2019
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6868898
28 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6845169
4 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6828444
27 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6819438
13 September 2019
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6809181
26 August 2019
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6795154
12 July 2019
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6744755
5 July 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6743331
3 June 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6718023
10 May 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6691313
11 April 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6660311
21 March 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6647303
21 March 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6647311
14 March 2019
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6640852
6 December 2018
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6604967
29 November 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6601044
29 November 2018
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6602343
18 October 2018
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6564002
4 October 2018
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6555041
11 September 2018
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6538058
12 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6509128
21 June 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6459348
7 June 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6514769
14 March 2018
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6371772
6 October 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6282908
5 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6284782
14 September 2017
ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6265930
31 August 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6256095
23 July 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6253651
4 June 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6249377
4 May 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6256257
3 April 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6293496
15 March 2017
Ballast Water Examination · ISPS III Exam · Administrative Inspection · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6105205
19 February 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6149360
19 January 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6147672
17 December 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6059937
15 December 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6058314
15 December 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6143033
1 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6050961
18 November 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6044063
1 November 2016
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6032953
15 September 2016
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5999506
22 August 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5998815
14 June 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5909629
26 May 2016
Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 5887994
18 May 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5881445
2 May 2016
Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 5867727
31 March 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5839027
18 March 2016
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5830698
18 March 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5836378
31 January 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5843735
3 January 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5795073
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 May 2026
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photo luminescent strip indicators place not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionally, escape roue signs and fire equipment location markings shall be of photo luminescent material or marked by lighting. PSCO observed extinguished top and bottom stairwell indicator lights in crew stair well.
74 SOLAS 20 II-2/13.3.2.5.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2026
Resolution: Crew replaced extinguished lights.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 May 2026
Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed obstructions in escape route in A/C Substation 6.1
74 SOLAS 20 II-2/13.1.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2026
Resolution: Crew removed obstructions from escape route.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 May 2026
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed hand truck blocking the closure of FSD 0.085 on the bulkhead deck.
74 SOLAS 20 II-2/9.4.1.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2026
Resolution: The crew moved the hand truck that was blocking the closure.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 May 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed combustibles stored in the following spaces: A/C Station on Deck 14, MVZ 6; the Lift Machinery Room Deck 12, MVZ 5; A/C Substation 6.1 Deck 1, and A/C Station 6.6.
74 SOLAS 20 II-2/9.2.2.3.2.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2026
Resolution: Crew removed the combustibles from the mentioned spaces.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 May 2026
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage beings. Secondary coxswains for lifeboats #4 and #8 were unaware of how to operate the lifeboats VHF Radio. Additionally, the coxswain for life boat #10 was initially unfamiliar with starting arrangements.
74 SOLAS 20 III/19.2.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2026
Resolution: Crew members were provided appropriate training.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 November 2025
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO's observed Fire Screen Door C010 to have missing gasket material around the door frame, compromising the A-Class Division.
74 SOLAS 01 II-2/30.2
10c
Action required: 10 - Deficiency Rectified
Resolved 22 November 2025
Resolution: Crew was able to repair gasket material on the spot with class approval.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 22 November 2025
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO's found the secondary boat commander for lifeboat #10 to be unfamiliar with starting the lifeboat.
74 SOLAS 20 III/19.2.1
10c
Action required: 10 - Deficiency Rectified
Resolved 22 November 2025
Resolution: Secondary boat commander was provided training of emergency duties.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2025
Resolved
The administration shall ensure that such lighting or photoluminescent equipment has been evaluateed, tested, and applied in accordance with the Fire Safety Systems Code. Any required low-location lighting (LLL) systems shall be approved by the adminstration. The LLL in the forward passenger stairwells on decks 4,6,7 and 8 were not iulluminated entirely to include the top and bottom indicators.
74 SOLAS (20) II-2/13.3.2.5.1
FSS Code 11.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2025
Resolution: PSC NOLA received a class report from DNV satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2025
Resolved
Escape doors from public spaces that are normally latached shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of force in the direction of escape flow. Escape doors from the Victorian Lounge do not have a quick release mechanism and consists of thumb latches that do not release when force is applied to the door release mechanism. The aft door on the Piano Lounge was found to be of the same configuration.
74 SOLAS (20) II-2/13.3.2.6.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2025
Resolution: PSC NOLA received a class report from DNV satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2024
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCOs observed fire door 11.007 not consistently closing due to a threshold.
74 SOLAS (2020) II/2/9.4.1.1.1
16 ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2024
Resolved 26 December 2024
Resolution: PSC NOLA received a class report from DNV satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. PSCOs observed the following fire doors do not latch fully closed: 8.019 and 7.052.
74 SOLAS (2020) II-2/9.4.1.1.5.1
16 ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2024
Resolved 26 December 2024
Resolution: PSC NOLA received a class report from DNV satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2024
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. PSCOs observed 02 escape doors from deck 12 children's room equipped with a locking device that prevents the release of the latch when pressure is applied to the release device.
74 SOLAS (2020) II-2/13.3.2.6.2
50 ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2025
Resolved 2 January 2025
Resolution: PSC Nola received class report from DNV satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 March 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulationsto ensure the ship in all respects will remain fit to proceed to sea. Vessel self reported that a 1 cm diameter hole was discovered within the ship's #2 stern thruster tunnel. Water ingressing through the #2 stern thruster tunnel was leaking into the #13 ballast water tank.
74 SOLAS 20 I/11
17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2024
Resolved 15 March 2024
Resolution: Doubler installation accepted by RO with a condition placed on the vessel for permanent repair at next dry dock (May 2025.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 December 2023
Resolved
Instructions for on-board maintenance of lifesaving appliances shall include for each appliance a checklist for carrying out inspections and schedule of periodic maintenance. Lifeboats #2, #6, #8, and #18 had damage on the rubber fenders that were not noted on the PMS.
74 SOLAS 20 III/36 16ac
11129
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2023
Resolved 25 December 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2023
Resolved
Electrical installations shall be such that the safety of
passengers, crew and ship from electrical hazards will be ensured. PSCO observed two electrical outlets on deck 3 bosun store without covers which presents a shock hazard to crewmembers.
74 SOLAS O4 II-1/40.1.3 - 16 ac
09209
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2023
Resolved 25 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 December 2023
Resolved
Manually operated call points complying with the Fire Safety Systems Code shall be installed throughout the accommodation spaces, service spaces and control stations. One manually operated call point shall be located at each exit. Manually operated call points shall be readily accessible in the corridors of each deck such that no part of the
corridor is more than 20 m from a manually operated call point. PSCO observed that manual call points 60577, Dl 6461 B0449, and 00436 were found with tape securing the face plate in place.
74 SOLAS 20 II-217.7 - 16 ac
07106
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2023
Resolved 25 December 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 December 2023
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluniinescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits.
Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO observed the exit mark on deck 3 bosun store extinguished and could not be activated.
74 SOLAS 20 II-2/13.S.2.5.1 - 10 c
07120
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 December 2023
Resolved 11 December 2023
Resolution: Exit mark lighting was fixed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 December 2023
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed portable water pipes in A.C. Station 1/1.1 and
near electronic escalator in main galley are leaking near electrical equipment.
74 SOLAS 04 II-1/26.1 - 10 C
09218
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 December 2023
Resolved 11 December 2023
Resolution: Repairs were made to pipes, class testified to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023
Resolved
The construction of doors and door frames in A class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO witnessed 10.25 roller shutter in the Diamonds Steakhouse did not close upon activation.
74 SOLAS 20 II-2/9.4.1.1.2 - 10 c
07105
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 December 2023
Resolved 11 December 2023
Resolution: Door was fixed and showed proper function.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 December 2023
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip IndIcators placed not more than 300 mm above the deck at all points of the escape route, including I angles and Intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO observed an extinguished 3 foot section of low location lighting at the starboard crew gangway.
74 SOLAS 20 II-2/13.3.2.5.1 - 10 c
07120
Action required: 10 - Deficiency Rectified
Due 11 December 2023
Resolved 11 December 2023
Resolution: The section of lighting was replace and is in working order.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 December 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that life boats #2 and #12's all around white lights were not operable and could not be energized by the crew.
74 SOLAS 20 III/20.2 - 10 c
11129
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 December 2023
Resolved 11 December 2023
Resolution: Lights were replaced on the Lifeboats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 June 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat #12 failed to start due to a malfunctioning battery rendering the lifeboat inoperable. 74 SOLAS 20 III/20.2, Code 17C to 10C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2023
Resolved 12 June 2023
Resolution: Lifeboat #12 battery was replaced. A loose connection was found to have prevented the battery from charging. Repaired connection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 June 2023
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. A-60 boundary in lift machinery space deck 14, AC trunk in deck 4, and in technical space on deck 12 was found with missing and deteriorating insulation. 74 SOLAS 20 11-2/9.2.2.3.1 - 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 June 2023
Resolved 12 June 2023
Resolution: ALl noted missing and worn SFP was replaced in-kind.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 June 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Coxswain on lifeboat #20 could not identify the location nor demonstrate the operation of the installed bilge pumps. Additionally, a stairway guide in the aft stairway could not explain how to evacuate a child to their muster location. 74 SOLAS 20 111/19.2.1 - 10C
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 June 2023
Resolved 12 June 2023
Resolution: Training was given to the crew and crew demonstrated required knowledge.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 12 December 2022
Resolved
The machinery shall be of an adequate design and construction and shall be so installed and protected as to reduce a minimum any danger to persons on board, due regard being paid to moving parts. Diesel generators (PGM) in the engine room were found with exposed rotating parts, creating a hazard to personnel. 74 SOLAS 20 II-1/26.1
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 21 December 2022
Resolution: Vessel provided Class Report attesting rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2022
Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. 03 "B-15" class doors were found with broken hinges and warped frames in: Garbage/recycle room, hydraulic substation entrance, and crew service lift entrance. 74 SOLAS 20 II-2/9.4.1.2.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 12 December 2022
Resolved 12 December 2022
Resolution: Doors repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 December 2022
Resolved
The means of escape shall be marked by lighting or photoluminescent strip indicators. Low location lighting adjacent to cabins 9275 and 9276 were found extinguished. 74 SOLAS 20 II-2/13.3.2.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2022
Resolved 12 December 2022
Resolution: Lighting repaired.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 December 2022
Resolved
The minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Penetrations in the A-60 bulkhead in A/C fan space 5.10S were not properly closed. 74 SOLAS 20 II-2/9
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 December 2022
Resolved 12 December 2022
Resolution: Penetrations were properly closed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 December 2021
Resolved
The means of escape.. shall be marked by lighting or photo luminescent strip indicators… if electric illumination is used…it shall be so arranged that the failure of any single light or cut in a lighting strip will not result in the marking being ineffective. Emergency escape lighting on deck 7, MVZ 6 in completely out.
SOLAS 20 II-2/13.3.2.5.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 December 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 December 2021
Resolved
… Smaller, enclosed rooms within…. That have less than 30% communicating openings to that space are considered separate spaces. The room between the carpentry and upholstery workshop has 30% communicating opening covered by plywood and metal storage containers.
SOLAS 20 II-2/9
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 December 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2021
Resolved
The condition of the ship and its equipment shall maintained to conform with the provisions fo the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Fresh water pipes throughout the ship were leaking causing random and intermittent problems with several electrical systems.
SOLAS 20 I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 September 2019
Resolved
11104 - Lifesaving - Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat/Rescue Boat #2 high pressure hydraulic line for steering gear was wasted and observed leaking. 74SOLAS(2014 Cons) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 27 September 2019
Resolution: PSCO verified replacement on high pressure hydraulic line of Life boat/Rescue boat #2. Repairs were satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2019
Resolved
Waste receptacles shall be constructed of non-combustable materials. Multiple combustable waste bins were found in galleys and were marked and used for collection of cardboard and paper.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2019
Resolved 11 April 2019
Resolution: Vessel replaced the waste receptacles with appropriate trash cans constructed of non-combustible materials.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 September 2018
Resolved
01 - 07101 Fire Prevention Structural Integrity - The minimum fire integrity of all bulkheads shall be prescribed in table 9.1. Bulkhead between backstage and electrical locker on deck 03 stbd side has 02 holes above light switch. 74SOLAS 14 Cons II-2 REG 9.2.2.3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2018
Resolved 4 October 2018
Resolution: Vessel provided RO/RSO documentation attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 September 2018
Resolved
02- 07105 Fire doors - Fire Doors in MVZ bulkheads galley boundaries and stairway enclosures shall be self closing. The following fire screen doors are not self closing to the latched position. 3.056 and 3.007. 74SOLAS 14 Cons CH II-2 REG 9.4.1.1.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 September 2018
Resolution: Ship Maintenance personal made repairs to the doors.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 September 2018
Resolved
03 - 11101 Lifeboats - All lifesaving appliances shall be in working order and ready for immediate use. Tender boat 20 raw water cooling hoses are deteriorated. 74 SOLAS 14 Cons Ch III reg 20.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2018
Resolved 4 October 2018
Resolution: Vessel provided RO/RSO documentation attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 September 2018
Resolved
04 - 07108 Ready Availability of Fire fighting equipment - The arrangements of water supply shall be in passenger ships of 1000 gross tonnage and upwards such that at least one effective jet of water is immediately available from any hydrant in an interior location. Fire hose at hydrant 0.32 was not connected to the fire main. 74 SOLAS 14 cons CH II-2 Reg 10.2.1.2.1.1.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 13 September 2018
Resolution: Ship personal connected the hose to the hydrant.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 March 2017
Resolved
0669-At least 3 two-way VHF radiotelephone apparatus shall be provided on every passenger ship. Only two radio's were provided. 74 SOLAS(14) Ch.III REG 6.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 March 2017
Resolved 26 March 2017
Resolution: Vessel received third radio.
Electrical › Electric Generation Source (service) › Generator
Issued 9 November 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel has 3 OOC DGs and 3 damaged DGs out of a total of six. Provide a report on visual/borescopic inspections of DG#1, DG#2, and DG#5 to the Coast Guard.
Action required: 705 - Other - as specified
Resolved 15 December 2016
Resolution: Vessel has 4 operational generators and has been issued a condition of class for the remaining 02 generators. Vessel is in compliance with SOLAS requirements.
Electrical › Electric Generation Source (service) › Generator
Issued 4 November 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vsl has 3 OOC DGs and 3 dmgd, out of 6. Provide a satisfactory report from tech+RO attesting to the suitability of a min of 4 generators for the intended voyage.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Resolution: Vessel has 04 operational generators and has been issued a condition of class for the remaining 02 genrators. The vessel will provide weekly reports as required by the condition of class until all 6 genrators are fully operational.
Electrical › Electric Generation Source (service) › Generator
Issued 4 November 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel has 3 OOC DGs and 3 damaged DGs out of a total of six. Provided a detailed contingency plan addressing impact to speed, manuvering and hotel loads.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2016
Resolution: Contingency plan provided and reviewed.
Electrical › Electric Generation Source (service) › Generator
Issued 4 November 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel has 3 OOC DGs and 3 damaged DGs out of a total of six. Provide repair plan for restoring all DG to service.
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 November 2016
Resolution: Repair plan provided.
Construction/Loadline › Structures › Door
Issued 18 March 2016
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosure other than power operated watertight doors and those which are normally locked shall close for hinged fire doors within 40s and no less than 10s from beginning of their movement. FSD A070, FSD 3.069 and door closed faster than 10s and FSD 5.029 did not close within 10s
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 31 March 2016
Resolution: doors examined to the satisfaction of Coast Guard Marine Inspector