Records from 2005 to 2024. Most recent: inspection, 27 June 2024.
Documentation record
Registered dimensions (L × B × D)460.8 ft × 78.0 ft × 36.5 ft
Registered tonnagegross 8,722 / net 8,722
ITC dimensions (L × B × D)460.8 ft × 78.0 ft × 36.5 ft
ITC tonnagegross 10,256 / net 6,678
BuilderMANITOWOC MARINE GROUP · STURGEON BAY, WI, UNITED STATES · built 2006
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6678 - Convention (Subpart B), Net Ton
8722 - Regulatory (Subpart C or D), Net Ton
19999 - Dead Weight, Ton
10256 - Convention (Subpart B), Gross Ton
8722 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 36
27 June 2024
Examination of Repairs · Vessel Attendance · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7943345
27 June 2024
Administrative Inspection · Examination of Repairs · Vessel Attendance · COI Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8227016
21 July 2022
Load Line/Change of Employment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7510101
22 November 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7356497
8 March 2021
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7148604
15 May 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6966287
2 March 2020
Periodic Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6915883
12 November 2019
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6854971
7 November 2018
Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6576224
12 December 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6319613
18 April 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6127145
15 November 2016
Cargo Tank Internal · Internal Structural Exam · In-Service Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6041739
11 January 2016
DAPI Audit · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5794902
22 September 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5727875
18 May 2015
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5128874
11 December 2014
Annual Inspection · MTSA Verification · DAPI Audit · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5037736
13 November 2014
In-Service Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5023408
6 November 2013
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4751832
16 August 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4413699
27 May 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4328297
10 January 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4233518
3 January 2012
Internal Structural Exam · COI Inspection · Drydock Exam · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4203473
24 October 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4175232
24 July 2011
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4093437
24 July 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4119339
17 February 2011
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3946968
19 March 2010
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3698562
3 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3689033
23 February 2010
MTSA Verification · Periodic Inspection · MARPOL Annex VI Survey · Administrative Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3684743
28 December 2009
Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3655782
3 May 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3468060
27 February 2009
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3424530
14 December 2008
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3413085
11 February 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3145490
15 September 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2779124
2 November 2005
Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Construction Oversight · In-Service Inspection · Initial Certification · Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2527247
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 March 2021
Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided.
Replace wasted glands on the #1 and #2 cargo pumps to maintain a gastight seal.
46CFR32.50-1
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2021
Resolved 9 March 2021
Resolution: Vapor glands were replaced by GMR rep.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 8 March 2021
Resolved
Ventilator openings shall be provided with efficient weathertight closing appliances.
Replace wasted gasket on the forward starboard natural ventilation cover.
46CFR42.13-40(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 March 2021
Resolved 8 March 2021
Resolution: GMR rep. replaced wasted gasket on the forward starboard natural ventilation cover.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 March 2021
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The marks shall be plainly visible.
Paint load lines to be plainly visible.
46CFR42.13–40(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 March 2021
Resolved 8 March 2021
Resolution: GMR Rep Painted load lines making them visible.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 November 2018
Resolved
The respective piping systems installed on barges shall have the necessary fittings for safe and efficient operation of the vessel. Fuel lines on the #1 and #4 prime movers for the generators leading to the second cylinder on each engine were leaking at the injection to the cylinders. Replace necessary gaskets/o-rings as recommended by the manufacture to eliminate fuel leaks. 46CFR32.35-1 46CFR56.01-1(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2018
Resolved 9 November 2018
Resolution: The engine manufacture representative replaced the o rings for the high pressure double jacketed fuel lines leading to injectors on the second cylinder for the #1 and #4 prime movers. MI witnessed proper operation with no leaks.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 December 2017
Resolved
AF01: Repair/replace corroded temperature relief valve on hot water heater in bathroom. Hot water heater is to remain secured until problem is fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 14 December 2017
Resolution: Received documentation from the port captain that the pressure/temperature relief was replaced in kind.
Engineering › Fuel Oil Service System › Hose
Issued 12 January 2016
Resolved
Renew fuel oil return line/hose on cargo pumps 1,2,3, and thruster prime mover. Renew fuel oil supply line/hose on cargo pump 3 and thruster prime mover.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 20 January 2016
Resolution: Renewed all hoses with J1942 approved hose.
Construction/Loadline › Hull › Hull Plating
Issued 24 July 2011
Resolved
Make forepeak available for inspection and certify gas free and safe workers. Authorized to discharge remaining cargo. Vessel is to have forepeak damage inspected by USCG and ABS prior to conducting any further operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2011
Construction/Loadline › Hull › Hull Plating
Issued 24 July 2011
Resolved
Vessel must submit a repair proposal and make permanent repairs to the damage on starboard bow sideshell during the next USCG/ABS dry-docking period in DEC11.
Action required: 705 - Other - as specified
Due 22 December 2011
Resolved 22 December 2011
Resolution: Cleared
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 5 December 2006
Resolved
CG-835 Issued in Error
Due 5 December 2006
Resolved 5 December 2006
Resolution: Issued in error to the wrong vessel.