OCEAN CASTLE is a 2005 freight ship. The Coast Guard has recorded 21 inspections since 2016, most recently in September 2024, along with 8 deficiencies and 1 operational control.
Records from 2016 to 2024. Most recent: operational control imposed, 19 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it8565 - Convention (Subpart B), Net Ton 35348 - Displacement, Ton 27428 - Dead Weight, Ton 18825 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 21
17 September 2024PSC B
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8003497
28 April 2023Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7677280
12 April 2022PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7420612
29 March 2022Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7420628
28 September 2021PSC B
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7322498
28 July 2021Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7270568
14 June 2021ISM Exam · PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7219791
5 April 2021Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7168953
20 January 2021PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7126986
17 January 2021PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7125785
6 November 2020Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7090733
3 August 2020Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7023376
5 May 2020PSC B
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6946707
4 September 2019Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6803412
10 April 2018Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6394451
4 February 2018ISPS III Exam · Administrative Inspection · PII Safety Exam
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 June 2021Resolved
74 SOLAS (14)II-2/4.1.1
Means shall be provided to control leaks of flammable liquids.
PSCO observed an active F/O leak on the No. 1 generator.
17ac changed to 15ac (see narative)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2021
Resolution: Cleared by Class
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 June 2021Resolved
74SOLAS (14) / CH IX / 3.1
ISM Code (2018) / 9.2
The company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrence.
Vessel was issued deficiency by USCG for F/O leaks on the No. 1 and No.2 generators on 17 Jan 2021. Deficiency was rectified by DNV-GL survey statement # 1550929 on 17 Jan 2021 stating the crew arrested cause of the fuel oil leaks. On 18 Jan 2021 vessel submitted report of non-conformities to V Ships Hamburg GMBH and Co KG. Under "NC 02" which addressed the generator fuel oil leak, no preventative action were identified.
Recommend external audit of V ship Hamburg GMBH and Co KG Safety Management System for adherence to and verification of implementing corrective and preventative actions.
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2021
Resolved 28 July 2021
Resolution: Received Company's Internal Audit as well as Class Society's Audit Report. (see documents tab)
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 January 2021Resolved
04114 - Emergency source of power - The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. PSCO observed quick closing valve for the emergency fuel shutoff in the closed position and questioned the operational readiness of the emergency generator. 74 Solas (04) 11-1/43.2 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 20 January 2021
Resolution: Training was given to the crew for the purposes of properly opening the emergency generator fuel shutoff valve. The valve was opened and the PSCO witnessed a satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 January 2021Resolved
07124 - Fire protection systems shall be kept in good order as to ensure their required performance if a fire occurs, including structural fire protection and fire resisting divisions. The "A" Class bulkhead separating the galley and the stairwell was discovered held together with duct tape on the corners and holding wall panels to the bulkhead. PSCO questions the effectiveness of this boundary if a fire were to occur. 74SOLAS(14)II-214.2.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2021
Resolution: Received Class report addressing repairs, report attached for further information.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 January 2021Resolved
07126 - Means shall be provided to control leaks of flammable liquids. PSCO observed active fuel leaks on the No. 1 and No. 2 generators in the vicinity of the fuel pumps and lube oil leaks w/ fuel accumulation in the drip pans and a significant amount of lube oil on the deck below the No. 2 generator. Oil soaked lagging was located in the purifier room on the No. 1 and No. 2 HFO purifiers. The No. 2 HFO purifier also had missing lagging on the fuel line. A small pump in the purifier room near the No. 1 HFO purifier has oil accumulation in the drip pan. 74SOLAS(04)II-2.4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2021
Resolution: Received Class report addressing repairs, report attached for further information.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 January 2021Resolved
07199 - Flammable liquid lockers shall be protected by appropriate fire extenguishing arrangement approved by the administration. Fuel samples are being stored in the steering gear room where fixed fire protection does not exist. 74SOLAS(04)II-210.6.3.2.
Action required: 10 - Deficiency Rectified
Resolved 17 January 2021
Resolution: Fuel samples were moved to paint locker.
PSCO Observed that the IOPP Form A list that the vessel has a MEPC60(33)oil content meter installed, but upon inspection of the oil content meter it was discovered that the vessel has a MEPC 107(49) content meter installed.
MARPOL Annex 1 Reg 6.1.2 MEPC 107(49)
ACTION Taken: 50ac
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 9 June 2016
Resolution: Vessel emailed updated IOPP supplement reflecting reference to correct MEPC for the type of system installed.
Fire Fighting › Portable Foam Applicators › General
Issued 19 April 2016Resolved
Each Extinguisher shall be clearly mounted in accordance with resolution A.951 (23)8.1. PSCO Observed multiple portable fire Extinguishers with labels that were not legible.
FSS CODE: Ch 4.2 resolution A.951 (23)
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 9 June 2016
Resolution: Photos from vessel depicting new labels and/or extinguishers
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.