MAURY USCG vessel records Sign in
← All vessels

ORION III

ORION III is a 2004 freight ship. The Coast Guard has recorded 16 inspections since 2005, most recently in October 2023, along with 7 deficiencies and 3 operational controls.

Records from 2005 to 2023. Most recent: inspection, 1 October 2023.

Built
2004
Last inspected
1 October 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9302748 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
797451
Flag
LIBERIA
—
Maury page id
psix-797451

Inspections, by type

…with no type recorded4
Years with a record 10 calendar years (2005–2023)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25754 - Convention (Subpart B), Net Ton
76602 - Dead Weight, Metric Ton
86824 - Displacement, Metric Ton
39727 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

1 October 2023 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7798145
28 October 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7585082
6 June 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6963448
21 December 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6877650
21 December 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7005518
19 December 2019 Ballast Water Examination · In-Service Inspection · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6871954
6 November 2010 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3878925
28 December 2009 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex VI Survey · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3649309
16 October 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3345906
15 August 2008 PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3292874
22 June 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2970089
1 September 2006 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2763556
12 November 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2533226
10 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2533139
5 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2529051
5 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2529080

Deficiency record · 7

14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 19 December 2019 Resolved
Oil filtering equipment shall be of design approved by the administration and shall be such as will ensure any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. PSCO was not able to verify proper operation of oil filtering equipment during 02 attempts of testing the equipment. OCM was not accurately reading parts per million. MARPOL Annex I/14.6 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2019
Resolved 20 December 2019
Resolution: PSC NOLA received a class report from NKK satisfying the requirment.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 December 2019 Resolved
Ships shall be designed, constructed, and maintained in compliance w/ the structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration. PSCO Observed a structural beam between the bilge well and top deck completely seperated. Provide report from cert. issuing authority on the integrity of the beam.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2020
Resolved 20 December 2019
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 December 2009 Resolved
0750: Fire Prevention- The Diesel Oil and Heavy Fuel Oil service tank remote safety shut-off valves to the main engine and auxiliary engines were found blocked open with a bolt preventing the valves from being remotely operated or closed in the event of a fire. SOLAS 74A II-2/4
Action required: 705 - Other - as specified
Due 28 December 2009
Resolved 31 December 2009
Resolution: Received, reviewed and accepted class report from NKK stating the outstanding deficiency was rectified. The class report stated that the bolts were removed and the valves were tested and found fully operational.
Accommodation/Occupational Safety › Potable Water System › General
Issued 28 December 2009 Resolved
0499:Accomodations- The vessel has 18% of the fresh water and drinking water on board. Provide invoice to the CG BCOB 01Jan2010 for the receipt of fresh water.
Due 1 January 2010
Resolved 30 December 2009
Resolution: Received invoice from Belle Chasse Marine Transportation for delivery of 155 metric tons of fresh water
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 15 August 2008 Resolved
The vessel has not prepared or submitted a Non-Tank Vessel Response Plan to the United States Coast Guard in accordance with the United States Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation Act of 2004.
Action required: 705 - Other - as specified
Resolved 16 October 2008
Resolution: Received proper documentation satisfying the requirement.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 22 June 2007 Resolved
Vessel has been issued two Load Line Certificates and corresponding assignment of freeboard documents per letter from class (NKK) "Authorization of Multiple Load lines" vessel is to keep second set of Load line documents under lock and key.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Resolution: Master put extra Load line document in a secure place.
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 12 November 2005 Resolved
Fourth Engineers flag state endorsement is invalid. Ship is to fax copy of new endorsement or application for renewal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 November 2005
Resolved 1 September 2006

Ownership record