Records from 1999 to 2021. Most recent: inspection, 11 August 2021.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 21.0 ft × 7.1 ft
Registered tonnagegross 104 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBARBOUR METAL BOAT WORKS · ST LOUIS, MO, UNITED STATES · built 1961
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLAIRE, OH
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Net Ton
104 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 10
11 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7283879
10 February 2004
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2003705
13 January 2004
Industry Initiated Exam
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1988811
26 July 2000
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 821304
20 July 2000
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 213154
26 June 2000
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 223136
15 November 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 731338
24 September 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 38647
24 September 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 218012
29 June 1999
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1087529
Operations/Management › Other Criminal/Civil Violations
Issued 10 February 2004
No resolution recorded
Failure to report a hazardous condition.
Action required: 705 - Other - as specified
Lifesaving › Line-Throwing Appliances
Issued 13 January 2004
Resolved
Renew wasted ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: New ring buoys placed on board.
Lifesaving › Lifejacket/PFD (General)
Issued 13 January 2004
Resolved
Provide serviceable lifejackets for each crewmember.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: PFDs in a quantity adequate for normal vessel manning were placed on board.
Navigation › Collision/Grounding Avoidance
Issued 13 January 2004
Resolved
Provide a working ships whistle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: The ships whistle tested sat.
Navigation › Piloting/Steering
Issued 13 January 2004
Resolved
Provied either an illuminated swing meter or an illuminated magnetic steering compass. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: A magnetic compass was installed.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 13 January 2004
Resolved
Provide (3) serviceable B-II fire extinguishers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: The required number of portable fire extinguishers had been placed on board.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 13 January 2004
Resolved
Prove proper operation of Fire Alarm Panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: Fire detection alarm panel tested satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 13 January 2004
Resolved
Provide pumping, piping, and discharge arrangements for machinery space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: A waste oil pumping and piping system was properly installed.
Fire Fighting › Combustible Materials
Issued 13 January 2004
Resolved
Clean bilges removing flotsam and excess oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: Bilges had been adequately cleaned.
Engineering › Fuel Oil Storage/Transfer System
Issued 13 January 2004
Resolved
Renew flame screens on fuel tank vents.
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: Satisfactory flame screens had been installed.
Documentation › Certificates/Documents
Issued 13 January 2004
Resolved
Place an orginal COD on board the vessel.
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: An original COD was placed on board.