YASA NESLIHAN

YASA NESLIHAN is a 2005 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in March 2022, along with 5 deficiencies and 2 operational controls.

Records from 2016 to 2022. Most recent: inspection, 15 March 2022.

Built
2005
Last inspected
15 March 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 March 2022
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9286566
798336
Flag
MARSHALL ISLANDS
Maury page id
psix-798336

Documentation record

Tonnage as PSIX records it27547 - Convention (Subpart B), Net Ton
82849 - Dead Weight, Metric Ton
93768 - Displacement, Metric Ton
42895 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

15 March 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7412261
16 September 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7292753
25 July 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6490663
11 August 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5968976
11 August 2016 In-Service Inspection · ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5969097
10 August 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5977543
25 July 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5952268
19 January 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5799365
13 January 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5796980

Deficiency record · 5

09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 16 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found corrosive liquid leaking onto other corrosive containers, shelving, deck and structural member of ship in steering gear room aft of steering gear. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 15 March 2022
Resolution: received report from vessel rectifying deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 September 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order. Found normally open SCV valve was closed. Crew opened valve.
Action required: 10 - Deficiency Rectified
Resolved 16 September 2021
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 August 2016 Resolved
0610 - Lifeboats - PSCO observed that the ship's port lifeboat was missing from its launching arrangement system following an accidental release of the lifeboat from its release hooks that had occurred the previous day and was reported to the USCG. 74 SOLAS (Am) III/20.2. 17a.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 17 August 2016
Resolution: Received report detailing repair plans for vessel and lifeboat. Extra life raft aboard until life boat is fully repaired.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 11 August 2016 Resolved
2535 - Development of plans for shipboard ops - Following the accident referenced in Deficiency #1, PSCO observed that the crew was unable to provide procedures for the proper use of the ship's fall preventer devices (FPD) in their SMS documents or SOLAS training manual. 74 SOLAS (Am) IX-3.1. ISM Code 7. MSC.1/Circ.1327. 16a.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 17 August 2016
Resolution: FPD considered non-mandatory for Marshall Island flag.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 August 2016 Resolved
2035 - Fire control plan - PSCO observed 2 doors leading to the steering gear room and 2 galley doors were held open by rope. Also, 2 stairway door were not self-closing. All 6 doors are required by the ship's fire control plan to be self-closing "A" class doors. 74 SOLAS (Am) II-2/15.2.4.1. 16a.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 17 August 2016
Resolution: Received class report attesting to repair of malfunctioning doors and removal of hold back devices.

Ownership record