Records from 2000 to 2004. Most recent: inspection, 26 July 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Hand Flares › Marking
Issued 26 July 2004
Resolved
Properly mark flare case.
Condition: Improper Installation
Due 9 August 2004
Resolved 5 August 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 July 2004
Resolved
Prove current enrollment in D & A program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2004
Documentation › Logs/Records › Logbook (official)
Issued 26 July 2004
Resolved
Provide previous bridge log.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2004
Stability › Unintentional Flooding › General
Issued 26 July 2004
Resolved
Repair aft comp door.
Condition: Improper/Lack of Maintenance
Due 9 August 2004
Resolved 13 August 2004
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 26 July 2004
Resolved
Correct emergency steering instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2004
Navigation › Piloting/Steering › Binnacle
Issued 26 July 2004
Resolved
Repair binnacle light.
Condition: Improper/Lack of Maintenance
Due 5 August 2004
Resolved 5 August 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 July 2004
Resolved
Prove proper operation of fixed gas fire ext system.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2004
Lifesaving › Visual Distress Signals (General) › Expired
Issued 28 June 2004
Resolved
Renew all flares. Flares one year past due.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Lifesaving › Lifebuoys › Serviceable
Issued 28 June 2004
Resolved
Renew Stbd Life Ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Fire Fighting › Fire Bucket › Quantity
Issued 28 June 2004
Resolved
Provide fire buckets. Missing one and lanyards missing from remainder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 28 June 2004
Resolved
Prove inspection of fixed fire system in E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 June 2004
Resolved
Prove proper operation of float light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 June 2004
Resolved
Prove proper operation of remote F/O Shut off.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 28 June 2004
Resolved
Inspect all portable exts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 28 June 2004
Resolved
Prove proper operation of horn.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 June 2004
Resolved
Properly secure batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2004
Construction/Loadline › Structures › Superstructure
Issued 11 July 2003
Resolved
USCG marine inspector to complete as-built verification of aluminum canopy top over cockpit.
Due 11 August 2003
Resolved 26 July 2004
Operations/Management › Passenger Operations
Issued 24 June 2003
Resolved
Comply with 46CFR 185.504 Passenger Count. No log for PM trip 23JUN03.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2003
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 June 2003
Resolved
Re-enforce/ replace MDE access hatch on main deck.
Condition: Design Flaw
Due 15 July 2003
Resolved 25 July 2003
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 24 June 2003
Resolved
Add Vsl name to two Child PFDs.
Condition: Improper/Lack of Maintenance
Due 2 July 2003
Resolved 2 July 2003
Operations/Management › Passenger Operations
Issued 24 June 2003
Resolved
Keep passenger count logs for at least one year.
Action required: 705 - Other - as specified
Resolved 2 July 2003
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 24 June 2003
Resolved
Provide adequet ground tackle for route. LEGACY COMPONENT DESC: Anchor Rope
Condition: Placed in Improper Service
Due 2 July 2003
Resolved 2 July 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 June 2003
Resolved
Repair stern light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 2 July 2003
Resolved 2 July 2003
Deck/Cargo › Mooring/Anchoring
Issued 24 June 2003
Resolved
Attach bitter of anchor line to vessel. LEGACY COMPONENT DESC: Anchor Rope
Condition: Placed in Improper Service
Due 2 July 2003
Resolved 2 July 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 24 June 2003
Resolved
Prove proper operation of fixed fire system.
Condition: Unknown
Due 2 July 2003
Resolved 2 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 June 2003
Resolved
Remove silcone/adhesive from rear passenger compartment escape hatch and prove proper operation. Silcone must be removed prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 24 June 2003
Operations/Management › Drills/Instruction
Issued 24 June 2003
Resolved
Improve MOB recovery system and demonstrate to the satisfaction of marine inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Placed in Improper Service
Due 15 July 2003
Resolved 25 July 2003
Operations/Management › Navigation Safety
Issued 24 June 2003
Resolved
Submit route/waypoints to [name withheld], CG GRU/MSO LIS for approval. LEGACY COMPONENT DESC: Navigation Underway, General
Due 2 July 2003
Resolved 2 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 June 2003
Resolved
Install required safety trim around new dodger. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Due 4 August 2003
Resolved 8 August 2003
Lifesaving › Lifebuoys
Issued 24 June 2003
Resolved
Properly mount MOB recovery devise. LEGACY COMPONENT DESC: Stowage
Condition: Improper/Lack of Maintenance
Due 4 August 2003
Resolved 8 August 2003
Operations/Management
Issued 24 June 2003
Resolved
Re-sbmit canopy plans to reflect actual materials for approval by [name withheld]/MSO LIS.
Condition: Improper Installation
Due 5 August 2003
Resolved 8 August 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 February 2003
Resolved
Remove excess materials from Fwd and Aft Passenger Cabins.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2003
Accommodation/Occupational Safety › Heating
Issued 11 February 2003
Resolved
Remove unauthorized Heating System and associated gear and equipment from E/R, Fwd Cabin and Aft Cabin.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2003
Navigation › Piloting/Steering
Issued 11 February 2003
Resolved
Mount Compass Deviation Table. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2003
Operations/Management › Passenger Operations
Issued 11 February 2003
Resolved
Comply with 46CFR 185.505, Passenger Count. LEGACY COMPONENT DESC: Passenger Count
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 February 2003
Resolved
Properly label all Escape Doors and Scuttles.
Condition: Unknown
Due 18 February 2003
Resolved 18 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 11 February 2003
Resolved
Re-Install Exhaust Check Valve at Stern. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 21 February 2003
Resolved 28 February 2003
Documentation › Logs/Records
Issued 11 February 2003
Resolved
Provide Ships Log. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 18 February 2003
Resolved 18 February 2003
Navigation › Collision/Grounding Avoidance
Issued 11 February 2003
Resolved
Prove proper operation of Ships Horn. LEGACY COMPONENT DESC: Danger Messages
Condition: Improper/Lack of Maintenance
Due 18 February 2003
Resolved 18 February 2003
Operations/Management › Drug and Alcohol Testing
Issued 11 February 2003
Resolved
Crew/Breakins cannot be employed until included in the DAPI Program. LEGACY COMPONENT DESC: Employee Coverage
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 28 February 2003
Electrical › Electrical Distribution System (service)
Issued 11 February 2003
Resolved
Provide proper Drip Cover for Electrical Buss Port Side of MDE. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 18 February 2003
Resolved 28 February 2003
Engineering › Sea-water System (primary cooling)
Issued 11 February 2003
Resolved
Install Proper Chaffing Gear and support brackets for Prop Shaft Cooling Line. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 18 February 2003
Resolved 28 February 2003
Electrical › Electrical Distribution System (service)
Issued 11 February 2003
Resolved
Properly Splice all Electrical Fan Connections in Both Cabins. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 18 February 2003
Resolved 12 February 2003
Engineering › Bilge Water Management System
Issued 11 February 2003
Resolved
Cap or remove Aux Bilge Pump Priming Line. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 18 February 2003
Resolved 11 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 11 February 2003
Resolved
Replace MDE Exhaust Flex Connector. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 21 February 2003
Resolved 28 February 2003
Operations/Management › Passenger Operations
Issued 11 February 2003
Resolved
Provide company policy for accuret passenger count proceedures and provide copy of passenger count sheet to CG GRU/MSO LIS for approval.
Condition: Placed in Improper Service
Due 19 February 2003
Resolved 28 February 2003
Navigation › Piloting/Steering
Issued 27 December 2002
Resolved
Provide compass deviation card. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Navigation › Piloting/Steering
Issued 27 December 2002
Resolved
Provide proper/current charts. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Navigation › Piloting/Steering
Issued 27 December 2002
Resolved
Provide Light List. Extened Req 02 weeks. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 27 January 2003
Resolved 27 January 2003
Navigation › Collision/Grounding Avoidance
Issued 27 December 2002
Resolved
Repair Anchor Light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 27 December 2002
Resolved
Replace Cockpit Fire Ext. (Rotted). LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 27 December 2002
Resolved
Provide approved bracket for cockpit fire ext. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Placed in Improper Service
Due 10 January 2003
Resolved 13 January 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 27 December 2002
Resolved
Inspect cabin fire ext. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 10 January 2003
Fire Fighting › Miscellaneous Items
Issued 27 December 2002
Resolved
Properly label fire buckets. LEGACY COMPONENT DESC: Fire Buckets
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Fire Fighting › Miscellaneous Items
Issued 27 December 2002
Resolved
Remove heater from engine room.
Condition: Placed in Improper Service
Due 10 January 2003
Resolved 10 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 27 December 2002
Resolved
Remove improper extension cords from service. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Placed in Improper Service
Due 10 January 2003
Resolved 10 January 2003
Electrical › Electric Supply System (service)
Issued 27 December 2002
Resolved
Improve Battery hold-down system. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Electrical › Electric Supply System (service)
Issued 27 December 2002
Resolved
Replace all white wires attached to batteries. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Deck/Cargo › Mooring/Anchoring
Issued 27 December 2002
Resolved
Properly mouse all anchor shackles. LEGACY COMPONENT DESC: Anchor Cable
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 10 January 2003
Lifesaving › Lifebuoys
Issued 27 December 2002
Resolved
Add Retro-Tape to Life Rings. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Stability › Watertight Integrity
Issued 27 December 2002
Resolved
Properly seal all E/R Bulkhead Penetrations. LEGACY COMPONENT DESC: E/R Bulkhead Penetrations.
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Engineering › Sea-water System (primary cooling)
Issued 27 December 2002
Resolved
Replace Sea Strainer Drain Plug (currently a nut and bolt) with proper type plug of compatable metal. Extended Req 02 weeks. LEGACY COMPONENT DESC: Sea Chest
Condition: Placed in Improper Service
Due 27 January 2003
Resolved 27 January 2003
Engineering › Sea-water System (primary cooling)
Issued 27 December 2002
Resolved
Replace Stuffing-Box Cooling Line. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 27 December 2002
Resolved
Replace line that is currently supporting J/W Cooling Line with a proper bracket. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Operations/Management › Drills/Instruction
Issued 27 December 2002
Resolved
Conduct and log monthly drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 13 January 2003
Operations/Management › Drug and Alcohol Testing
Issued 27 December 2002
Resolved
Provide proper DAPI paper work. LEGACY COMPONENT DESC: Recordkeeping
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 10 January 2003
Operations/Management › Passenger Operations
Issued 27 December 2002
Resolved
Improve Passenger Count System. LEGACY COMPONENT DESC: Passenger Count.
Condition: Placed in Improper Service
Due 10 January 2003
Resolved 10 January 2003
Documentation › Certificates/Documents
Issued 27 December 2002
Resolved
Post all Documents as per 46CFR.
Condition: Unknown
Due 10 January 2003
Resolved 13 January 2003
Communications › Alarms/Indicators
Issued 27 December 2002
Resolved
Prove proper operation of bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Due 10 January 2003
Resolved 13 January 2003
Operations/Management
Issued 27 December 2002
Resolved
Overdue HULL & ISE. Haul-out vessel NLT 10JAN03. must complete succesfull HULL & ISE by 10JAN03. Not allowewd to carry passengers after 10JAN03 untill all reqs related to this RIN are completed to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Hull & ISE
Action required: 705 - Other - as specified
Due 10 January 2003
Resolved 13 January 2003
Navigation
Issued 27 September 2001
Resolved
Binnacle light broken off and ooc.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Lifesaving
Issued 27 September 2001
Resolved
03 Life jackets missing VSL name.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Construction/Loadline
Issued 27 September 2001
Resolved
Anchor locker scuttle on main deck unable to be dogged down. Dog frozen in placeby corrosion.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Lifesaving
Issued 27 September 2001
Resolved
Stiffen deck in way of eng hatch cover and secure eng hatch cover.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Documentation
Issued 27 September 2001
Resolved
Fax proof of collection sights for DAPI program.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Lifesaving
Issued 27 September 2001
Resolved
Add Retro Tape to both sides of both Life Rings.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Lifesaving
Issued 27 September 2001
Resolved
Properly secure all batteries in E/R and battery cover.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Navigation
Issued 27 September 2001
Resolved
Post COI & EAP notice.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001
Lifesaving
Issued 27 September 2001
Resolved
Verify currency of Port Fire Ext inspection.
Condition: Unknown
Due 26 October 2001
Resolved 29 October 2001