Records from 2016 to 2022. Most recent: inspection, 14 October 2022.
Inspection history · 8
14 October 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7577648
22 February 2022
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7399838
18 August 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7265477
25 September 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6274340
23 August 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5980994
29 March 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5841892
9 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812318
15 January 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797025
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 15 January 2016
Resolved
The ring, line and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Loadline marks on both port and starboard sides are rust in color.
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 25 January 2016
Resolution: Received report stating that Plimsoll mark has been corrected
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 January 2016
Resolved
MARPOL (2011) Annex I Regulation 14.2
Except as specified in paragraph 3 of this regulation, any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying of paragraph 7 of this regulation. The oily water separator was inoperable.
Due 15 January 2016
Resolved 15 January 2016
Resolution: Corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 15 January 2016
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Two hold back hooks were on class "A" boundary doors.
Due 15 January 2016
Resolved 15 January 2016
Resolution: Corrected on the spot.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 15 January 2016
Resolved
SOLAS (2004) II-1 Regulation 45.2
Main and emergency switchboards shall be so arranged to give easy access as may be needed to apparatus and equipment without danger to personnel. Where necessary, non-conducting mats or gratings shall be provided at the front and rear of the switchboard. Anti-conductive matting was missing in the emergency generator space.
Due 15 January 2016
Resolved 15 January 2016
Resolution: Corrected on the spot.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 January 2016
Resolved
SOLAS (2014) III Regulation 13.1.4
LSA Code Chapter IV Regulation 4.4.8.12
Each survival craft shall be stowed fully equipped as required by this chapter and the Code. Food rations shall be kept in airtight packaging and be stowed in a watertight container. Two rations were not airtight.
Due 15 January 2016
Resolved 15 January 2016
Resolution: Corrected on the spot.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 January 2016
Resolved
SOLAS (2004) II-1 Regulation 26.3.6
Means shall be provided whereby normal operation of proplusion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Special consideration shall be given to the malfunctioning of the sources of water pressure. The emergency generator was leaking jacket water.
Due 15 January 2016
Resolved 15 January 2016
Resolution: Corrected on the spot.