Records from 2016 to 2026. Most recent: inspection, 11 April 2026.
Inspection history · 6
11 April 2026
PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8346164
21 April 2025
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8116169
20 December 2024
Deficiency Check · PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8049690
15 September 2021
PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7294323
18 August 2021
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7290197
7 April 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5849298
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 24 December 2024
Resolved
A ISM-DOC Shall be issued to every company which complies with the requirements of the ISM Code. The validity of the ISM-DOC should be subject to an annual verification by the Administration within three months before or after the anniversary date. No annual verification has been completed by the Administration for 2024.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2025
Resolution: Class provided documentation that their second annual audit was completed on 20MAR25.
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 23 December 2024
Resolved
A ISM-DOC shall be issued to every company which complies with the requirements of the ISM Code. The validity of the ISM-DOC should be subject to annual verification by the administration within three months before or after the anniversary date. No annual verification has been completed for the ISM-DOC by the Administration for 2024.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 December 2024
Resolved
Doors fitted in boundary bulkheads of machinery space of catecorgy A shall be reasonably gastight and self-closing. Door leading into the the engine space from the main deck failed to self-close and was found to have a penetration. The door is an A-60 self-closing per the fire control plan.
74 SOLAS (2001 Cons) II-2/47.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 December 2024
Resolved
Plans shall be permantely exhibited for guidance of ships officers clearly showing fire sections enclosed by class "A" divisions...02 A-Class self-closing doors leading to the pilot house and quarters did not properly self close, and 01 B-class self-closing door leading to the mess deck was found to have penetrations. Doors were not being maintained IAW the fire control plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 7 April 2016
Resolved
Where more than one fireman's outfit is stored on board, they shall be stored in widely separated positions. Fireman's outfits were stored in same locker. Ensure Fire control plan is updated accordingly.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 August 2021
Resolved 18 August 2021
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement.