MAURY USCG vessel records Sign in
← All vessels

HEBERT TIDE

HEBERT TIDE is a 2006 offshore supply vessel. The Coast Guard has recorded 14 inspections since 2005, most recently in April 2026, along with 6 deficiencies.

Records from 2005 to 2026. Most recent: inspection, 11 April 2026.

Built
2006
Last inspected
11 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9273545 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
798950
Flag
MEXICO
303235000, 338538000, 367083030, 368607000 (licence lapsed)
Maury page id
psix-798950

Inspections, by type

Years with a record 11 calendar years (2005–2026)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it473 - Convention (Subpart B), Net Ton
1235 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH2797MMSI 338538000 · cancelled · compulsorily equipped · granted 9 January 2014, cancelled 27 January 2021
WDG5810MMSI 303235000 · cancelled · compulsorily equipped · granted 18 October 2012, cancelled 10 April 2014
WDD3151MMSI 368607000 · expired · compulsorily equipped · granted 27 June 2006, cancelled 27 August 2016
WDC8190MMSI 367083030 · expired · voluntarily equipped · granted 23 December 2005, cancelled 27 February 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

11 April 2026 PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8346164
21 April 2025 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8116169
20 December 2024 Deficiency Check · PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8049690
15 September 2021 PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7294323
18 August 2021 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7290197
7 April 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5849298
24 January 2011 COI Inspection · DAPI Audit · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3924759
12 February 2010 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3686076
14 July 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3534210
8 February 2009 MTSA/ISPS Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3451847
23 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276799
14 April 2008 Administrative Inspection · ACP Annual Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3183805
31 January 2007 MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2864719
6 June 2005 Initial Certification · Construction Oversight · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2527218

Deficiency record · 6

01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 24 December 2024 Resolved
A ISM-DOC Shall be issued to every company which complies with the requirements of the ISM Code. The validity of the ISM-DOC should be subject to an annual verification by the Administration within three months before or after the anniversary date. No annual verification has been completed by the Administration for 2024.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2025
Resolution: Class provided documentation that their second annual audit was completed on 20MAR25.
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 23 December 2024 Resolved
A ISM-DOC shall be issued to every company which complies with the requirements of the ISM Code. The validity of the ISM-DOC should be subject to annual verification by the administration within three months before or after the anniversary date. No annual verification has been completed for the ISM-DOC by the Administration for 2024.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 December 2024 Resolved
Doors fitted in boundary bulkheads of machinery space of catecorgy A shall be reasonably gastight and self-closing. Door leading into the the engine space from the main deck failed to self-close and was found to have a penetration. The door is an A-60 self-closing per the fire control plan. 74 SOLAS (2001 Cons) II-2/47.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 December 2024 Resolved
Plans shall be permantely exhibited for guidance of ships officers clearly showing fire sections enclosed by class "A" divisions...02 A-Class self-closing doors leading to the pilot house and quarters did not properly self close, and 01 B-class self-closing door leading to the mess deck was found to have penetrations. Doors were not being maintained IAW the fire control plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 7 April 2016 Resolved
Where more than one fireman's outfit is stored on board, they shall be stored in widely separated positions. Fireman's outfits were stored in same locker. Ensure Fire control plan is updated accordingly.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 August 2021
Resolved 18 August 2021
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 24 January 2011 Resolved
Provide Drug and Alcohol testing program in accordance with 46 CFR Part 16. Brazilian mariners are not currently subject to random drug testing.
Action required: 705 - Other - as specified
Resolved 17 January 2014
Resolution: The vessel is no longer operating in Brazil so the deficiency has been cleared.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.