← All vessels
CHRYSALIS
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northwest District (CGD-NW) · Other hulls named CHRYSALIS
CHRYSALIS is a 2005 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2005, most recently in December 2025, along with 53 deficiencies — 2 with no resolution recorded — and 3 casualty investigations between 2007 and 2017.
Records from 2005 to 2025. Most recent: inspection, 2 December 2025.
- Built
- 2005
- Last inspected
- 2 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 53 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2007–2017
Identity
1179439
WDD5067
799063
Flag
UNITED STATES
367153190
Maury page id
psix-799063
Inspections, by type
…with no type recorded6
…past their stated due date2
Years with a record
18 calendar years (2005–2025)
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderMID-CITY STEEL FABRICATION · LA CROSSE, WI, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portRICHLAND, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
73 - Regulatory (Subpart C or D), Gross Ton
178 - Convention (Subpart B), Gross Ton
63 - Convention (Subpart B), Net Ton
73 - Regulatory (Subpart C or D), Gross Ton
178 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD5067MMSI 367153190 · active · compulsorily equipped · granted 13 September 2016, expires 30 November 2026
WDC8296MMSI 367084760 · expired · compulsorily equipped · granted 6 January 2006, cancelled 12 March 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 38
2 December 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8276428
5 November 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8260553
2 October 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8245647
20 June 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8163107
13 November 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8034831
8 November 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7821949
21 June 2023
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7721021
29 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7598143
18 October 2021
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7332696
13 October 2020
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7098064
7 October 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6831416
7 January 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6608046
9 October 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6555872
25 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6548306
16 August 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6573510
20 June 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6512962
31 May 2018
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6430966
24 December 2017
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6328692
23 December 2017
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6331743
5 December 2017
Damage Survey · Drydock Extension
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6318823
3 October 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6278091
30 September 2016
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6011602
28 September 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6081125
27 September 2016
Type not recorded
No type recorded · Station Cape Disappointment · USCG Northwest District (CGD-NW) · Activity 6011814
3 March 2016
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5765088
17 March 2014
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4817285
13 January 2012
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4224188
2 December 2011
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4200141
29 July 2009
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3549782
18 February 2009
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3220983
17 July 2008
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3260175
16 November 2007
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3130087
29 October 2007
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3087423
30 July 2007
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3011713
17 July 2007
Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2998334
10 May 2007
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2926783
24 May 2006
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2657499
8 August 2005
Hull Examination · Construction Oversight
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2543353
Deficiency record · 53
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 November 2024
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Fixed CO2 system's installed pressure-switch shutdown of the port main engine failed testing. Correct issue to the satisfaction of the USCG Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 November 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel does not have a valid Communications Act Safety Radiotelephony Certificate. Obtain certificate and submit proof to USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 November 2023
Resolved
Fixed Fire System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system. CO2 System were tested individually and together and failed to activate the system during testing. Western fire techs tightened all fitting and tests were repeated with the same results. Repair or replace and provide satisfactory test report from service agency.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 8 November 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Testing devices not onboard. Provide devices and proof of compliance with 46 CFR 4.06.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 November 2023
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Station license expired, obtain valid license. 47 CFR 80.13
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 8 November 2023
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. PA system not operable, test to the satisfaction of attending inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 November 2023
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle, a vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. Ship's whistle not operable due to inoperable compressor at the time of inspection, test to the satisfaction of attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 November 2023
Resolved
A vessel on a Rivers route must carry 3 hand red flare distress signals and 3 hand orange smoke distress signals. Signals not onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First Aid Kit not on board.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 November 2022
No resolution recorded
Upon first being employed and prior to getting underway for the first time on a particular vessel as to the duties the crew member is expected to perform. Crew training shall be logged or otherwise documented. Vessel has been inactive for over a year. Prior to getting underway for the first time all required logs and drills shall be conducted onboard and recorded.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 November 2022
Resolved
Each ring life buoy on a vessel must be approved IAW 160.050. Stbd side forward ring buoy showed signs of excessive wastage and cracking life line on ring was tested and failed a tug test. Vessel is to repair or replace with in 30 days.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 November 2022
Resolved
Each ring life buoy on a vessel must be approved IAW 160.050. Port side aft life ring light was inoperable and upon attempting to properly place light in mount, mount cracked and fell from wall.Vessel is to repair and replace wihin 30 days.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 November 2022
Resolved
Fixed Fire System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system. CO2 System were tested individually and together and failed to activate the system during testing. Western fire techs tightened all fitting and tests were repeated with the same results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2022
No resolution recorded
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Generator set 1(One) was found inoperable and needs to be overhauled before proper operation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 November 2022
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. It was discovered that the fuel filters have been replaced since last inspection and the required flame bowls have been removed from multiple filters and were not reinstalled.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
Vsl is broadcasting: No dimension information (AIS Antenna Position ABCD values equals 0).
Construction/Loadline › Hull › Bottom Plating
Issued 31 May 2018
Resolved
Hull plate approx 6ft x 5ft under stbd engine space between the keel and stabilizer fin found with severe pitting. Crop and renew to original construction prior to taking passengers.
Construction/Loadline › Hull › Bracket
Issued 24 December 2017
Resolved
Provide report attesting to the satisfactory condition of the hull to include skegs, rudders, props, and prop shafts. For any necessary repairs, plans must be submitted and approved by local OCMI prior to work being conducted. All work and tests shall be to the satisfaction of the attending MI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 October 2017
Resolved
Fixed fire fighting system and all portable fire extinguishers have not been serviced.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 October 2017
Resolved
Approximately 2 inch bulkhead penetration on aft E/R bulkhead does not have cap preventing vapor tightness of E/R fixed fire fighting system.
Engineering › Bilge Water Management System › Pump
Issued 3 October 2017
Resolved
Main fixed bilge pump is inoperable.
Communications › Radio Communications › EPIRB
Issued 17 October 2016
Resolved
AS 1 - Vessel EPIRB does not have new vessel name or updated registration. 46CFR185.604(c)
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 17 October 2016
Resolved
RP 2 - Vessel has several nonmetallic penetrations 46CFR182.720
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 October 2016
Resolved
AS 3 - Vessel does not have official number or name on hull. 46CFR67.121
Documentation › Logs/Records › Drug Test Records
Issued 17 October 2016
Resolved
AS 4 - Provide proof of members enrolled in consortium 46CFR16.201
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 October 2016
Resolved
AS 5 - STBD running light bulb is out. 46CFR183.420
Engineering › Fuel Oil Service System › Piping
Issued 17 October 2016
Resolved
RP 6 - Provide grounding wire on fuel fill. 46CFR182.450
Fire Fighting › Fire Pumps › Arrangement
Issued 17 October 2016
Resolved
RP 7 - Bilge/ fire pump needs check valve for interconnected piping. 46CFR182.520(h)
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 October 2016
Resolved
JS 8 - Provide structural fire protection insulation for engine room overhead. 46CFR177.410(c)4
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 October 2016
Resolved
JS 9 - Provide guards for engine equipment (rotating belts). 46CFR177.970
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 17 October 2016
Resolved
AS 10 - Provide servicing report for heat activating CO2 engine room system. 46CFR181.400
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 March 2016
Resolved
Double hose clamp both Port & Stbd Main engine R/W Hoses from pump to heat exchanger, IAW 46 CFR 182.720(e)(3)(v)(B).
Lifesaving › Hand Flares › Quantity
Issued 3 March 2016
Resolved
Provide onboard 02 hand night flares, IAW 46 CFR 180.68(a)(1).
Navigation › Piloting/Steering › Marine Charts
Issued 3 March 2016
Resolved
Provide onboard up-to-date navigational chart for the area of operation, IAW 46 CFR 184.420(a)(1).
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2009
Resolved
Provide current Drug and Alcohol Consortium Contract
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2009
Resolved
Provide current MIS report.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 18 February 2009
Resolved
Provide emergency broadcast placard on the bridge.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 February 2009
Resolved
Remove dead end wiring 02 deck stern.
Lifesaving › Hand Flares › Quantity
Issued 17 July 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 July 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Radio Communications › EPIRB
Issued 17 July 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifefloat › Serviceable
Issued 17 July 2008
Resolved
REPAIR 1/2" x 3" AREA IDENTIFED DURING INSPECTION ON THE LIFEFLOAT.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 July 2008
Resolved
REMOVE REPAIR DEAD END WIRING ON STBD STERN.
Lifesaving › Lifebuoys › Serviceable
Issued 30 July 2007
Resolved
REPLACE ONE WASTED RING BUOY
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 30 July 2007
Resolved
ENSURE THAT ALL LIFEJACKETS ARE PERMANENTLY MARKED WITH VESSEL NAME
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 July 2007
Resolved
REPLACE MISSING LIGHT GUARD IN FORWARD STORAGE AREA.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 July 2007
Resolved
REMOVE TWO PORTABLE FUEL CONTAINERS FROM ENGINE SPACE.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 30 July 2007
Resolved
Install new retro reflective tape on two life jacket.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 May 2006
Resolved
Provide copy of the fixed fire fighting system servicing report. IAW 46 CFR 176.810
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 24 May 2006
Resolved
Provide Current light list and rules of the road. IAW 46 CFR 184.420
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2006
Resolved
Provide First Aid Kit IAW 46 CFR 160.041
Personnel › Training › First Aid/CPR
Issued 24 May 2006
Resolved
Provide proof of First Aid & CPR certification for at least 50% of the crew. IAW NVIC 1-91
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 May 2006
Resolved
Provide proof of name change on the vessel documentation. IAW 46 CFR 67.123 Paper work submited to the NVDC on May 25, 2006.
Casualty record · 3
16 November 2007Routine · role: Involved in a Marine Casualty · activity 3130087
28 September 2016Routine · role: Involved in a Marine Casualty · activity 6081125
23 December 2017Routine · role: Involved in a Marine Casualty · activity 6331743
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
NAPLES PRINCESS (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.