MAURY USCG vessel records Sign in
← All vessels

CAPTAIN D LEMPESIS

CAPTAIN D LEMPESIS is a 2005 freight ship. The Coast Guard has recorded 17 inspections since 2005, most recently in June 2026, along with 6 deficiencies and 7 operational controls.

Records from 2005 to 2026. Most recent: inspection, 8 June 2026.

Built
2005
Last inspected
8 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9364801 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
799433
Flag
LIBERIA
—
Maury page id
psix-799433

Inspections, by type

…with no type recorded5
Years with a record 10 calendar years (2005–2026)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it29996 - Convention (Subpart B), Gross Ton
18486 - Convention (Subpart B), Net Ton
61965 - Displacement, Metric Ton
53466 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

8 June 2026 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8387786
11 May 2023 PSC B
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7685751
21 February 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7143766
12 February 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7140180
27 January 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7128720
20 January 2021 PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7127646
19 March 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6929004
7 June 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6431403
14 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6365587
11 March 2018 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6365564
9 January 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6063470
26 August 2014 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4957171
30 June 2012 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4361876
10 May 2012 COE-Dockside · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4309146
20 March 2009 MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3436216
1 December 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2538735
26 November 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2540872

Deficiency record · 6

Engineering › Freshwater Generation System › Piping
Issued 26 August 2014 Resolved
1499-The Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all its respects will remain fit to proceed to sea without danger to the ship or persons onboard. Brine discharge on freshwater generation system has two existing soft patches in the way of welds. SOLAS 09 (cons) 1/11(a) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 September 2014
Resolution: Received Class Report attesting to repairs. See report attached to activity.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 August 2014 Resolved
1499- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Flange on cooling pipe for ship generator has wasted weld. SOLAS 09 (cons) II-2/9.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2014
Resolution: Received Class Report attesting to repairs. See report attached to activity.
Fire Fighting › Structural - A Class Divisions › Store-rooms
Issued 26 August 2014 Resolved
0710- The fire integrity of the divisions shall be maintained at openings and penetrations. The vessel installed new electrical and wi-fi cables by removing fire stop caullking from multi cable penetrations in electrical rooms on multiple decks resulting in the loss of fire integrity of those spaces. SOLAS 09 (cons) II-2/9.1.1 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2014
Resolution: Received Class report attesting to repairs. See report attached to activity.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 2 July 2012 Resolved
inoperable alarm of #6 piston colling oil flow.
Due 31 July 2012
Resolved 2 July 2012
Resolution: vessels class submited report attesting to the satisfactory repiar of the #6 piston cooling alarm
Navigation › Piloting/Steering › Marine Charts
Issued 20 March 2009 Resolved
Vessel does not have charts of the Mississippi River as required by SOLAS and 33 CFR 164.33 on board. Provide receipt of the charts to the U.S. Coast Guard.
Action required: 705 - Other - as specified
Due 20 March 2009
Resolved 27 March 2009
Resolution: Updated charts, 3382 and 3384 of the Mississippi river have been purchased delivered to the vessel.(see narrative for details)
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 20 March 2009 Resolved
Vessel's bunkering lines have not been hydrostatically tested as per 33 CFR 156.170. Vessel is prohibited from conducting bunkering operations in U.S. waters until test is complete. Provide proof of test to the Coast Guard.
Action required: 703 - Prior to bunkering operations
Due 20 March 2009
Resolved 27 March 2009
Resolution: Conducted liquid(hydrostatic) pressure test of the Vessels Fuel bunkering lines as per 33 CFR 156.170. All test completed satisfactory. (see narrative for details)

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.