Records from 2006 to 2023. Most recent: inspection, 28 August 2023.
Inspection history · 17
28 August 2023
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7769625
22 June 2022
PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7483203
24 November 2021
PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7355657
11 July 2021
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7254024
15 April 2021
PSC A · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7164108
15 April 2021
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7178982
10 November 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6570383
18 November 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6043774
19 February 2016
Deficiency Check
Physical examination · Activities Europe · Activity 5818033
13 August 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4953837
13 June 2014
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4890504
18 March 2010
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3698195
21 August 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3304857
13 May 2008
MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3205477
7 May 2008
ORV Letter of Designation
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3201012
12 May 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2647515
19 April 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2628258
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 August 2023
No resolution recorded
THE MEANS FOR SECURING THESE DORORS WEATHERTIGHT AND WATERTIGHT SHALL CONSIST OF GASKETS.
VESSEL'S DOOR LEADING TO DECKHOUSE WORKSHIP, ENGINE ROOM ESCAPE TRUNK AND STEERING GEAR ROOM, WERE FOUND TO HAVE WASTED GASKETS.
ICLL 12.1
16(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 22 June 2022
Resolved
Start air relief valve discharges toward machinery room entrance & hot water heater p/v was plugged. Must relieve toward safe location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2022
Resolved 30 June 2022
Resolution: Class Report.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2022
Resolved
Engine room 115 volt distribution panel has missing ground detection bulbs and circuit breakers missing. Hot water pump is not properly wired to the control box above it and not using suitable appropriate cable.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 22 July 2022
Resolved 30 June 2022
Resolution: Class Report.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2022
Resolved
Found various junction boxes with missing covers, hanging devices not properly secured, and actual boxes hanging by the wire connections. These were found in steering compartment and starboard aft engine.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 22 July 2022
Resolved 30 June 2022
Resolution: Class Report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 April 2021
Resolved
THE ALARM SYSTEM SHALL OPERATE BOTH AUDIBLE AND VISIBLE SIGNALS AT THE MAIN STATIONS REFERRED TO IN PARAGRAPH (a) OF THIS REGULATION. ALARM PANEL ON BRIDGE WAS IN A FAULT STATUS, AND WAS UNABLE TO BE CLEARED. CITE: 60SOLAS II/61(c).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 14 May 2021
Resolution: Vessel submitted class and tech report attesting to the rectification.
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 13 June 2014
Resolved
The 1st and 2nd Mates (Nigerian) serving onboard is a non-U.S. Citizen in violation of 46 USC 8103(b)(3) and 46 CFR 15.720.
Due 13 June 2014
Resolved 10 November 2018
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 13 June 2014
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 13 June 2014
Resolved 10 November 2018
Personnel › Certificates/Documents/Licenses › MMD, Able Seaman
Issued 13 June 2014
Resolved
The three ABs, (2-Ghanaian & 1-Nigerian) serving onboard is a non-U.S. Citizen in violation of 46 USC 8103(b)(3) and 46 CFR 15.720.
Due 13 June 2014
Resolved 10 November 2018
Personnel › Certificates/Documents/Licenses › MMD, Ordinary Seaman
Issued 13 June 2014
Resolved
The Ordinary Seaman (Ghanain) serving onboard is a non-U.S. Citizen in violation of 46 USC 8103(b)(3) and 46 CFR 15.720.
Due 13 June 2014
Resolved 10 November 2018
Personnel › Certificates/Documents/Licenses › MMD, Wiper
Issued 13 June 2014
Resolved
The two (2) (Ghanaian/Nigerian) oiler serving onboard are a non-U.S. Citizen in violation of 46 USC 8103(b)(3) and 46 CFR 15.720.
Due 13 June 2014
Resolved 10 November 2018