MAURY USCG vessel records
← All vessels

MADDOX

MADDOX is a 2005 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in August 2025, along with 5 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 4 August 2025.

Built
2005
Last inspected
4 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 August 2025
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9277486
799712
Flag
LIBERIA
Maury page id
psix-799712

Documentation record

Tonnage as PSIX records it20211 - Convention (Subpart B), Gross Ton
10948 - Convention (Subpart B), Net Ton
39677 - Displacement, Metric Ton
32353 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

8 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

4 August 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8201931
31 January 2025 COE-Administrative
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8072670
12 September 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8001005
1 September 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7548807
9 September 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7319772
16 August 2021 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7278514
16 December 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6865478
19 September 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5998724

Deficiency record · 5

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 August 2021 Resolved
In addition to the requirements contained elsewhere in the present regulations ships shall be designed, constructed and maintained in complicance with the electrical requirements of a classification society recognized by the Administration or with applicable national standards of the Administration which provide an equivalent level of safety. Vessel crew installed 110 volts outlet behind master switchboard in Engine Control Room without class approval. 74SOLAS(04)II-I/3-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2021
Resolved 9 September 2021
Resolution: Received class survey showing satisfactory repair. 110V socket was removed and disconnected from main switchboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 August 2021 Resolved
The rating or appropriate setting of the overload protective device for each circuit shall be permanently indicated at the location of the protective device. Installed BWMS circuit breaker lacking required label for rating or appropriate setting for circuit. 74SOLAS(04)II-I/45.6.2
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2021
Resolved 9 September 2021
Resolution: Rceived class survey showing satisfactory repair. BWMS circuit breaker label with system rating indicated was put in place.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 August 2021 Resolved
Cables and wiring shall be installed and supported in such a manner to avoid chafing or other damage. Black cable for BWMS lacking antichafing sheilding and secured with zipties. 74SOLAS(04)II-I/45.5.5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2021
Resolved 9 September 2021
Resolution: Received class survey showing satisfactory repair. The power cable for BWTS cleaning pump was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 August 2021 Resolved
Install and operate a BWMS that has been approved by the Coast Guard under 46 CFR part 162 in accordance with 33 CFR 151.1512(b) of this subpart. Following installation of a BWMS, the master, owner, operator, agent, or person in charge of the vessel must maintain the BWMS in accordance with all manufacturer specifications. BWMS airline currently secured with safety wire, provide approved installation plan for BWMS. 33CFR151.1510(a)3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2021
Resolved 9 September 2021
Resolution: Received class survey showing satisfactory repair. Safety wires were removed, and U-clamp supports were installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 August 2021 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI/1, or with applicable national standards of the Administration which provide an equivalent level of safety. Two valves on hydraulic suction lines in steering gear room had wire tied to handles that prevented valves from closing. 74SOLAS(04)II-I/3-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 August 2021
Resolved 16 August 2021

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.