Records from 2011 to 2026. Most recent: inspection, 9 March 2026.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 9 March 2026
Resolved
No vessel may operate a vessel that has a toilet, unless it is equiped with An operable Type II or III device that has a label on it under § 159.16 or that is certified under § 159.12 or § 159.12a. MSD has a leak and no chemical tablets. Provide chemical tablets and repair leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2026
Resolution: Uploaded objective evidence of alarm set point test.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 9 March 2026
Resolved
Each owner or managing operator must develop procedures to routinely examine, maintain, and replace capstans, winches, and other machinery used to connect the towing vessel to the tow. Vessel does not have tow gear maintenance procedures. Provide tow gear maintenance procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 March 2026
Resolution: Verified tow gear maintenance procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2026
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, 160.176, or 160.255 for each person on board. Vessel authorized to carry 7 persons total, only 6 lifejackets on board. Provide additional life jacket prior to carry over 6 persons on vessel.
Action required: 705 - Other - as specified
Due 23 March 2026
Resolved 9 April 2026
Resolution: Uploaded objective evidence of added life jacket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Shaft seals leaking excessively. Make repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
Resolution: Uploaded objective evidence of shaft packing fixed
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 March 2026
Resolved
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey.Three welds on vertical support frames for upper fwd deck have cracked welds. Also, one vertical suport frame under the aft deck, port side, has a cracked weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 April 2026
Resolution: Uploaded objective evidence of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 March 2026
Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. No evidence of random drug program. Provide documentation of enrollment in random drug and alcohol program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2026
Resolution: Received and uploaded objective evidence or enrollment in drug and alcohol program.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2025
Resolved
The portable fire pump must be self-priming and power-driven, with: a minimum capacity of at least 300LPM (80 gpm) at a discharge of not less than 414 kPa (60 psi). Portable fire pump did not self-prime and did not have sufficient discharge pressure. Replace or repair fire pump to the satisfaction of an attending Marine Inspector.
46 CFR 142.325(e)(1)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2025
Resolution: New portable fire pump provided and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Main switch board panels were not secured and swinging open, 2 dead ended wires in the overhead above the port main engine. Repair hazards to the satisfaction of an attending Marine Inspector.
46 CFR 143.400(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2025
Resolution: Installed outlet, removed dead end wires.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 May 2025
Resolved
All bilge levels and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar ass practicable. Machinery space bilge level has excessive oil accumulation. Remove oil to the satisfaction of an attending Marine Inspector.
46 CFR 142.220(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2025
Resolution: oil has been removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2025
Resolved
Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112. All life jacket lights were expired. Replace life jacket lights to the satisfaction of an attending Marine Inspector.
46 CFR 141.340(g)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2025
Resolution: new life jacket lights installed.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 16 May 2025
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Master could not determine if electronic charts were up to date or meet NVIC 01-16. Provide evidence of satisfaction to an attending Marine Inspector.
46 CFR 140.705(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2025
Resolution: New chart plotter installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2025
Resolved
Each towing vessel must carry at least one appropriately-sized life jacket for each person on board. Vessel is missing 01 life jacket. Provide 01 life jacket to the satisfaction of an attending Marine Inspector. Vessels manning is restricted to 06 persons until rectification.
46 CFR 141.340(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2025
Resolution: Required life jackets provided.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 May 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Port main engine fuel supply and return lines were leaking. Repaired on the spot.
46 CFR 143.220(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 16 May 2025
Resolution: Repaired on the spot
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 May 2024
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Fire dampers for engine room exhaust not closing. Make repairs, demonstrate proper operation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2024
Resolution: Inspected sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 May 2024
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive oil in engine room bilges. Remove oil.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2024
Resolution: Inspected sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 May 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Generator in the engine room has an oil leak between the prime mover and the generator. Make repairs NLT 30MAY2024, to satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2024
Resolved 24 May 2024
Resolution: Uploaded objective evidence of leak repairs on generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port and starboard propulsion engines have cooling water leaks. Make repairs to satisfaction of attending CG MI.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2024
Resolved 24 May 2024
Resolution: Uploaded objective evidence of leak repairs on engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 May 2024
Resolved
Pressure vessel relieved valves must be tested twice in five, not to exceed 3 years. No records of test avalilable. Provide documentation of test.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2024
Resolved 3 May 2024
Resolution: Inspected sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Aft deck generator junction box is missing cable packing on one fitting. Seal junction box from weather/water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 May 2024
Resolution: Inspected sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Port and starboard, forward winch wires severely damaged. Replace winch wires in kind prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Inspected sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 May 2024
Resolved
In the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station”;
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 May 2024
Resolution: Inspected sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2021
Resolved
Fuel shutoff valve did not operate as designed.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 March 2021
Resolved 18 April 2022
Resolution: Repaired from earlier event.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 June 2019
Resolved
Provide ventilation closures for engine room spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 11 July 2019
Resolution: Company POC provided documentation and pictures showing closures are installed and function properly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2019
Resolved
Provide a flammable locker for the storage of flammable and combustible products.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 11 July 2019
Resolution: Flammable locker was provided and properly installed.