Records from 2007 to 2025. Most recent: inspection, 18 August 2025.
Documentation record
Registered dimensions (L × B × D)35.7 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portGLOUCESTER POINT, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2025
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Life ring Buoy grab line was deteriorated and had breaks in the line.
46 CFR 180.70 (b)
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: VSL replaced life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2025
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Lifeline and pendants: The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Life float lifelines and pendants are deteriorated and not serviceable.
46 CFR 180.175 (a) & (f)
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: VSL replace life float grab lines
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 July 2024
Resolved
46 CFR 180.175(f)(4): The life float light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Waterlight did not have manufacture approved batteries installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 1 August 2024
Resolution: Replaced batteries to be IAW manufacture instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2024
Resolved
46 CFR 180.70(d)(1): Each floating waterlight on a ring life buoy must be approved in accordance with § 161.010 in subchapter Q of this chapter. Waterlight did not have manufacture approved batteries installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 1 August 2024
Resolution: Replaced batteries to be IAW manufacture instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Vessel was missing appropriate marking of adult life jackets via stenciling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 4 August 2023
Resolution: Vessel representative sent pictures as sufficient evidence of proper marking of adult life jacked stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 July 2023
Resolved
The life float light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Vessel was missing the waterlight and had the incorrect lanyard size for life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 19 September 2023
Resolution: MI verified presence and operation of waterlight for life float as well as the appropriate length and construction of lanyard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. It must be approved in accordance with § 161.010, have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy, and must be attached to the lanyard with a corrosion-resistant clip. Vessel was missing a waterlight on the ring life buoy. Vessel limited to daytime operation only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 19 September 2023
Resolution: MI verified presence and operation of waterlight for ring buoy as well as the appropriate length and construction of lanyard.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 20 July 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel was missing an EPIRB. Vessel limited to no more than 3NM from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 19 September 2023
Resolution: Verified presence of EPIRB, mounted in a float free arrangent with approved hydrostatic release and NOAA registration.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 20 July 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shut off markings should be openly marked on the deck for easy visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 19 September 2023
Resolution: Verified approved markings/instructions for emergency fuel shutoff.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel was missing visual indicators for each automatic bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 19 September 2023
Resolution: Verified the operation of the bilge pump indicator lights while bilge pumps were operational.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 July 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel had 02 cableways between the machinery and accommodation spaces that must be sealed with fire retardant sealant.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 19 September 2023
Resolution: Verified cableways from fwd accom space to engine room were sealed using marine grade 3M sealant.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 August 2016
Resolved
Provide updated charts for operating area.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 20 September 2016
Resolution: Owner purchased Oceangraphix charts of appropriate area/scale.
Construction/Loadline › Structures › Door
Issued 1 August 2016
Resolved
Replace severed hatch drain on E/R after hatch.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 20 September 2016
Resolution: Owner replaced flexible tubing on drain.
Engineering › Fuel Oil Service System › Piping
Issued 1 August 2016
Resolved
Add additional hose clamps on various piping systems on vessel (bilge, fuel).
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 20 September 2016
Resolution: Owner placed additional hose clamps on bilge system.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 August 2016
Resolved
Provide approved brackets for portable fire extinguishers.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 20 September 2016
Resolution: Owner installed manufacturer approved fire extinguisher brackets on all fire extinguishers.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 1 August 2016
Resolved
Prove proper operation of single side band radio.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 20 September 2016
Resolution: Single side band radio is operational.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 August 2016
Resolved
Prove operation of DSC capability of VHF radio.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 20 September 2016
Resolution: Saw owner program radio with MMSI number according to manufacturer instructions. GPS is also connected.
Stability › Unintentional Flooding › General
Issued 1 August 2016
Resolved
Install coamings on engine room downflooding points. Provide list of materials and layup procedure.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 20 September 2016
Resolution: Completed all requirements; installed coamings along E/R natural vents.