ATLANTIC DAWN

ATLANTIC DAWN is a 2005 tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in May 2020, along with 5 deficiencies and 2 operational controls.

Records from 2016 to 2020. Most recent: inspection, 27 May 2020.

Built
2005
Last inspected
27 May 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2020
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9307152
800507
Flag
PANAMA
Maury page id
psix-800507

Documentation record

Tonnage as PSIX records it56172 - Convention (Subpart B), Gross Ton
32082 - Convention (Subpart B), Net Ton
121482 - Displacement, Metric Ton
105712 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

27 May 2020 COC-TVE Renew · Ballast Water Examination · PSC C
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6958963
16 March 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6927598
17 October 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6838589
20 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6735116
5 May 2019 ISPS II Exam · Deficiency Check · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6674317
16 May 2018 Ballast Water Examination · ISPS II Exam · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6411426
7 June 2017 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6163642
1 March 2016 COC-TVE Renew · ISPS II Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5820572
1 March 2016 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5825174

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2019 Resolved
07116-LIGHTING IN CARGO PUMP ROOMS EXCEPT EMERGENCY LIGHTING, SHALL BE INTERLOCKED WITH VENTILATION SUCH THAT THE VENTILATION SHALL BE IN OPERATION WHEN SWITCHING ON THE LIGHTING. FAILURE OF THE VENTILATIONS SYSTEM SHALL NOT CAUSE THE LIGHTING TO GO OUT. PSCO NOTED THAT VENTILATION WAS NOT INTERLOCKED WITH LIGHTING AS REQUIRED by 74 SOLAS(04)II-2/4.5.10.1.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 May 2019
Resolved 5 May 2019
Resolution: Lighting/Ventilation interlock for the pump room was tested and found to be in good working order.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 May 2019 Resolved
06199- THE HIGH LEVEL ALARM REQUIRED BY 33 CFR PART 39 MUST ACTIVATE A VISIBLE AND AUDIBLE ALARM SO THAT IT CAN BE SEEN AND HEARD ON THE VESSEL WHERE CARGO TRANSFER IS CONTROLLED. PSCO NOTED HIGH LEVEL AUDIBLE ALARM NOT OPERATIONAL IN THE CARGO CONTROL ROOM 46 CFR 39.2007(c)(3).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2019
Resolved 20 June 2019
Resolution: Repairs and operational testing of the cargo tank high level audible alarms located in the in the cargo control room was conducted by the RO, Lloyd's Register, and found satisfactory.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 1 March 2016 Resolved
1575-ECHOSOUNDER-ALL SHIPS OF 300 GROSS TONNAGE AND UPWARDS SHALL BE FITTED WITH AN ECHO-SOUNDING DEVICE. SHIP'S ECHO-SOUNDING DEVICE IS NOT OPERATIONAL. 74 SOLAS (CONS. 2014) CH.V, REG. 19.2.3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2016
Resolved 2 March 2016
Construction/Loadline › Markings › Load Line Mark
Issued 1 March 2016 Resolved
1220-FREEBOARD MARKS-THE LOAD LINE MRAK SHALL BE PLACED AMIDSHIPS AND AT A DISTANCE EQUAL TO THE ASSIGNED SUMMER FREEBOARD. THERE IS A SECOND LOAD LINE MARK PLACED BELOW VALID LOAD LINE MARK ON PORT AND STBD SIDES OF VESSEL. ICLL 66 (CONS. 2005) I/5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 March 2016
Resolved 2 March 2016
Documentation › Markings/Placards › Warning Signs
Issued 1 March 2016 Resolved
1840-INSTRUMENTATION-THE HIGH LEVEL ALARM AND TANK OVERFILL ALARM ARE REQUIRED TO BE INDENTIFIED WITH THE LEGENDS "HIGH LEVEL ALARM" AND "TANK OVERFILL ALARM" IN BLACK LETTERS ON A WHITE BACKGROUND. HIGH LEVEL ALARM AND TANK OVERFILL ALARM LEGENDS ARE IDENTIFIED WITH RED LETTERS ON A YELLOW BACKGROUND. 46 CFR 39.2007(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 March 2016
Resolved 2 March 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.