MAURY USCG vessel records Sign in
← All vessels

TORM SOFIA

TORM SOFIA is a 2005 tank ship. The Coast Guard has recorded 9 inspections since 2006, most recently in May 2023, along with 5 deficiencies and 1 operational control.

Records from 2006 to 2023. Most recent: inspection, 9 May 2023.

Built
2005
Last inspected
9 May 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9295086 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
800719
Flag
SINGAPORE
—
Maury page id
psix-800719

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (2006–2023)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it41503 - Convention (Subpart B), Gross Ton
20972 - Convention (Subpart B), Net Ton
86139 - Displacement, Ton
72660 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

9 May 2023 COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7684188
26 May 2021 PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7203148
25 May 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6423218
9 January 2017 COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6067877
22 April 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5860147
3 March 2014 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4808928
27 May 2008 Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3218733
2 February 2006 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2578214
2 February 2006 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2578235

Deficiency record · 5

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2021 Resolved
In tankers, a system for continuous monitoring of the concentration of hydrocarbon gases shall be fitted. When the hydrocarbon gas concentration reaches a pre-set level, which shall not be higher than 10% of the lower flammable limit, a continuous audible and visual alarm signal shall be automatically effected in the pump room, engine control room, cargo control room to alert personnel to potential hazard. Vessel’s cargo pump room fixed gas detection system not properly operating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2021
Resolved 29 May 2021
Resolution: Received class report. System was calibrated and tested to the satisfaction of RO.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 27 May 2008 Resolved
Unable to inspect cargo pump room due to lack of Marine Chemist. Space must be certified and inspected prior to departure. SOLAS 11-2 Reg 4 5.10-Pumproom
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2008
Resolution: Obtained and secured a Marine Chemist Certificate and conducted a visual inspection of the pumproom with no deficiencies noted.
Electrical › Electric Generation Source (emergency) › Generator
Issued 27 May 2008 Resolved
Emergency generator Inop due to failed starting components. Vessel to make repairs inport to the satisfaction of Class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2008
Resolution: Received a class report from [name withheld] attesting to repairs to the emergency generator. A new electric starter was fitted, the fly wheel magnetic RPM sensor was replaced and new batteries were installed. The generator was tested in the automatic
Electrical › Electric Generation Source (emergency) › Generator
Issued 27 May 2008 Resolved
Starting system INOP.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2008
Resolved 6 June 2008
Resolution: Tech replaced starting componets, op check all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 27 May 2008 Resolved
Unable to obtain a Marine Chemist during COC inspection at anchorage.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2008
Resolution: Pumproom, certified gas-free, inspected pump room, all Sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.