MAURY USCG vessel records
← All vessels

MARINA JACK II

MARINA JACK II is a 2005 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in June 2025, along with 31 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 16 June 2025.

Built
2005
Last inspected
16 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 June 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9791
800831
Flag
UNITED STATES
Maury page id
psix-800831

Documentation record

Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderMID-CITY STEEL FABRICATION · LA CROSSE, WI, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSARASOTA, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 23 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it178 - Convention (Subpart B), Gross Ton
83 - Regulatory (Subpart C or D), Gross Ton
63 - Convention (Subpart B), Net Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

16 June 2025 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8136796
10 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7915591
9 August 2023 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7763344
6 July 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7735167
25 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7427200
3 August 2021 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7272573
23 March 2021 Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7160577
23 June 2020 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6985067
6 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6882657
11 June 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6678066
16 August 2018 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6513231
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512824
18 June 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6414849
7 July 2017 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6146417
5 January 2017 Deficiency Check · Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6060335
11 April 2016 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5848956
29 January 2016 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5805338
6 January 2016 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5791924

Deficiency record · 31

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 June 2024 Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pressure dropped to 20psi with the hose open. 46 CFR 181.300
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2024
Resolved 19 June 2024
Resolution: Replaced fire pump and demonstrated proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2024 Resolved
Each item of life saving equipment determined by the MI to not be in serviceable condition must be repaired of replaced. MI found the forward life ring to be faded and worn, replace. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 24 July 2024
Resolution: New life ring onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2024 Resolved
Non conductive mats or grating must be provided on the deck in front of each switchboard. MI noted mat was missing. 46 CFR 183.330
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 24 July 2024
Resolution: Non conductive mat was infront of the switch board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in machinery spaces. The visual indicator was always illuminated. Audible alarm functioned properly. 46 CFR 182.530
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 24 July 2024
Resolution: Bilge high level alarm was re wired and is working properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2024 Resolved
Electrical equipment must be installed and maintained to protect passengers and from electrical hazards such as fire. MIs observed drop cords and electrical strip style surge protectors for lighting systems and drink dispersal in the forward stores and fuel tank room. Remove and replace with permanent installations. 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 24 July 2024
Resolution: Extension cords were removed.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 10 June 2024 Resolved
a vessel more than 65 feet must carry a rescue boat unless the OCMI determines that the vessel is able to act as its own rescue vessel and the recovery of a helpless person can be observed from the operating station. The master has no direct line of sight from the operating station. Vessel must devise a plan to allow for the master to observe the recovery. 46 CFR 180.210
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 24 July 2024
Resolution: CCTV camara now shows the recovery station on a screen at the operating station.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 14 July 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 27 July 2023
Resolution: Captain provide report of crew that are working and have taken test with negative results and the crew that are pending waiting for results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Marine Inspector identified engine room bilge suction was unable to draw a suction during operational test of the system. Troubleshoot problem and show proper operation of bilge system from all compartments with suction points. 46 CFR 182.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 14 July 2023
Resolution: Bilge pump and suction in all spaces is operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Marine Inspector identified bilge high level float alarm that was missing parts holding float in place and mounted horizontally in aft engine room causing it to not work properly. 46 CFR 182.530(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 14 July 2023
Resolution: All high level alarms are operational.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 July 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Marine Inspector identified stbd ventilation closure for the engine room was not closing completely when actuated. Unable to test port side due to inaccessibility. Repair and show proper operation of both port/stbd ventilation closures for the engine room. 46 CFR 182.460(i)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 27 July 2023
Resolution: Verified both port/stbd engine room ventilation louvers operated properly and sealed properly.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 July 2023 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Marine Inspector reviewed training log and found that the latest drills were conducted 7/2023. Previous drills had been conducted 4/2022. Talking with new Captain and crew that they were unsure what was expected during drills. All satisfactory drills are to be completed in the presence of CG Marine Inspector. 46 CFR 185.520(a) 46 CFR 185.524(a) 46 CFR 185.420(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 14 July 2023
Resolution: Master and crew conducted satisfactory MOB and Fire Drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 July 2023 Resolved
A hatch exposed to the weather must be watertight. Identified watertight hatch located stbd side for the steering compartment that is not sealing properly alloying water intrusion into the space. 46 CFR 179.360(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 14 July 2023
Resolution: Hatch gasket replaced/added and is watertight.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 10 July 2023 Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station if: (2)The vessel has an oceans, coastwise, limited coastwise, or Great Lakes route; and (3) The vessel carries more than 49 passengers. Radar was found to be inoperative due to part failed linking the radar unit with the exterior mounted antenna unit. Reduced route to lakes, bays and sounds route. 46 CFR 184.404(a)(2)(3)
Action required: 705 - Other - as specified
Due 10 July 2023
Resolved 14 July 2023
Resolution: Radar is operational.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 10 July 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. All alcohol tested swabs onboard were expired. Alcohol testing swabs that are not expired must be on board unless Captain can produce alternate means to test individuals within the required timelines. 46 CFR 4.06-15(a)(1)
Action required: 705 - Other - as specified
Due 10 July 2023
Resolved 14 July 2023
Resolution: New alcohol testing devices added to the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 10 July 2023 Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, a serious marine incident, the marine employer shall take all practicable steps to have each individual engaged or employed on board the vessel who is directly involved in the incident chemically tested for evidence of drug and alcohol use as required in this part. Found that the newly hired Captain was not completely aware of the process(s) to be done during serious marine incident as per the drug consortium requirements/regulations. Captain must show knowledge of the drug consortium and its particulars/requirements. 46 CFR 4.06-1(b)
Action required: 705 - Other - as specified
Due 10 July 2023
Resolved 27 July 2023
Resolution: Talked with Captain about the drug and alcohol program and verifying that he knew particulars of the program and his role as the Supervisor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2023 Resolved
Vital systems are those systems that are vital to a vessel's survivability and safety. Marine Inspector identified leak in discharge piping from the fire pump passed the gauge right side of piping passed valve leaking at threaded joint. 46 CFR 182.710(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 14 July 2023
Resolution: Pipe connection replaced and not leaking at full op.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2023 Resolved
Vital systems are those systems that are vital to a vessel's survivability and safety. (6) Propulsion system and its necessary auxiliaries and controls. Marine Inspector identified stbd main engine raw water piping from sea strainer to engines raw water pump that could be turned by hand at the elbow joint. 46 CFR 182.710(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 14 July 2023
Resolution: Pipe replaced and tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2023 Resolved
Vital systems are those systems that are vital to a vessel's survivability and safety. (6) Propulsion system and its necessary auxiliaries and controls. Marine Inspector identified port main engine with a constant coolant leak on the forward part of the engine. 46 CFR 182.710(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 14 July 2023
Resolution: Hose replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Captain could not provide a 3rd fire technian servicing report for portable extinguishers and the fixed-gas fire extinguishing system. **Provide report within seven days of the technicians report and what they conducted tests on.** 46 CFR 176.810(b)(2)
Action required: 705 - Other - as specified
Due 10 July 2023
Resolved 14 July 2023
Resolution: Fixed fire extinguishing and portable extinguishers serviced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 July 2023 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radiobeacon (EPIRB). Identified EPIRB did not have the name of the vessel marked on it. *Corrected on the spot. 46 185.604(c)
Action required: 10 - Deficiency Rectified
Due 10 July 2023
Resolved 10 July 2023
Resolution: Captain labeled EPIRB with vessels name.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 July 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel has a COI anniversary date of 05APR. The vessel was required to have an annual inspection no later than 05JUL23, and the vessel has not had an annual inspection for this year. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2023
Resolved 10 July 2023
Resolution: Completed annual inspection that the vessel had passed on the backside of the 180 day window required to conduct inspection in.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 6 July 2023 Resolved
Fireplaces or other space heating equipment with open flames are prohibited from being used on all vessels. Identified burners used for heating chaffing dishes. Crew found proper electrical heating elements for the chaffing dishes. *Corrected on the spot.* 46 CFR 184.202
Action required: 10 - Deficiency Rectified
Due 10 July 2023
Resolved 10 July 2023
Resolution: Replaced burners with electrical heating elements for the chaffing dishes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2022 Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. Identified fuel hose leading from the racor filter to the high pressure fuel pump that was chaffing on the starboard main diesel engine. 46 CFR 182.455(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 13 June 2022
Resolution: A new fuel hose was installed from Racor filter assembly to injector pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2022 Resolved
Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe. Identified saltwater leaking around the fiberglass exhaust bubbler on the port main diesel engine. 46 CFR 182.425(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2022
Resolved 13 June 2022
Resolution: A new exhaust bubbler was installed on port MDE.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 25 April 2022 Resolved
Fireplaces or other space heating equipment with open flames are prohibited from being used on all vessels. Sterno open flame heating was being used under warming food trays. 46 CFR 184.202(b)
Action required: 10 - Deficiency Rectified
Due 25 April 2022
Resolved 25 April 2022
Resolution: Captain had the sterno containers removed from all food warming trays.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2021 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 161.150. Main deck, aft ring buoy found to have wasted outer cover exposing interior buoyancy material. Deemed unserviceable. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 19 April 2021
Resolution: Vessel representative submitted photo via e-mail of new serviceable life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2021 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Found 110 adult life jackets to have deteriorated retroreflective material that will not last till the first annual inspection. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 19 April 2021
Resolution: Vessel representative submitted photos via e-mail of life jackets with new serviceable retroreflective material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2021 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 161.150. Upper deck ring buoy found to have deteriorated retroreflective material that will not last till the first annual inspection. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 19 April 2021
Resolution: Vessel representative submitted photos via e-mail of the upper ring buoy with new serviceable retroreflective material.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
Vsl is broadcasting: Measure length in FT (Vsl dimension Must be measured in meters).
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 7 January 2020
Resolution: Vessel representative provided copy of, October 19, 2018, email indicating technician had corrected AIS errors: MMSI # is 367106730, official # 1179966.
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2017 Resolved
Repair two areas of low readings, approximately 8'7 1/2" X 17 1/2" of bottom plate, port/starboard, in way keel, third compartment aft of bow, below the fuel tank.
Action required: 705 - Other - as specified
Resolved 13 January 2017
Resolution: Witnessed a satisfactory air test to two areas of approximately 8'7 1/2" X 17 1/2" X 1/4" bottom plate, port/starboard, in way keel, third compartment aft of bow, below the fuel tank.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 11 April 2016 Resolved
Ensure proper operation of RPM gauge.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: RPM gauge repaired and operational.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.