ALLIANCE FAIRFAX

ALLIANCE FAIRFAX is a 2005 freight ship. The Coast Guard has recorded 78 inspections since 2005, most recently in February 2026, along with 35 deficiencies, 7 operational controls, 1 with no removal date recorded and 11 casualty investigations between 2013 and 2024.

Records from 2005 to 2026. Most recent: inspection, 12 February 2026.

Built
2005
Last inspected
12 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9303546 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
800854
Flag
UNITED STATES
366771000
Maury page id
psix-800854

Inspections, by type

…with no type recorded23
Years with a record 21 calendar years (2005–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)636.4 ft × 105.6 ft × 68.9 ft
Registered tonnagegross 59,705 / net 17,912
ITC dimensions (L × B × D)636.4 ft × 105.6 ft × 68.9 ft
ITC tonnagegross 59,705 / net 17,912
BuilderDAEWOO SHIPBUILDING & MARINE ENGINEERING CO., LTD. · Okpo, KOREA, REPUBLIC OF · built 2005
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 7 November 2025 · expires 31 December 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59705 - Convention (Subpart B), Gross Ton
17912 - Convention (Subpart B), Net Ton
31368 - Displacement, Ton
15821 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WLMQMMSI 366771000 · active · compulsorily equipped · granted 24 June 2022, expires 21 September 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

12 February 2026 Administrative Inspection
Administrative · Activities Europe · Activity 8323590
31 January 2026 Administrative Inspection
Administrative · Activities Europe · Activity 8304543
4 August 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8201980
10 July 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8182117
4 March 2025 COI Inspection · MSP COI Oversight · MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8087708
7 September 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8000931
16 July 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7959323
14 July 2024 Type not recorded
No type recorded · Activities Europe · Activity 7989166
30 May 2024 Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7923435
2 April 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7888463
14 September 2023 Type not recorded
No type recorded · Activities Europe · Activity 7812637
27 May 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7697488
21 April 2023 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7658023
23 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626733
9 December 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7606910
14 October 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7577630
11 April 2022 MSP Periodic Oversight · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7428975
17 February 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7397637
16 February 2022 Type not recorded
No type recorded · Activities Europe · Activity 7399645
30 August 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7400849
11 May 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7194072
23 March 2021 Administrative Inspection · MSP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7161365
25 October 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7084068
25 October 2020 Type not recorded
No type recorded · Activities Europe · Activity 7084076
12 May 2020 Administrative Inspection · MTSA/ISPS Verification · MSP COI Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6947818
11 May 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6950375
21 March 2020 Administrative Inspection
Administrative · Activities Europe · Activity 6929882
10 March 2020 Plan Review (Other than "T")
Administrative · Activities Europe · Activity 6923796
3 December 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6875339
8 August 2019 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7650139
9 July 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6742869
17 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6716333
31 May 2019 Administrative Inspection · MSP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6699373
28 December 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6603525
6 December 2018 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6595386
5 December 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6592444
23 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6528441
16 July 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6481326
11 June 2018 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6441219
31 May 2018 MSP Periodic Oversight · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6423760
6 March 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6367225
3 March 2018 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6381346
11 December 2017 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6322666
13 October 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6288235
13 October 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6289265
11 August 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6237258
9 May 2017 MTSA/ISPS Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6148514
13 November 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6040918
6 August 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5963784
6 August 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5969736
23 April 2016 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5860641
14 April 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5854375
7 April 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5849331
8 February 2016 Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5851243
24 December 2015 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5786753
15 December 2015 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5785141
30 November 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5771884
9 November 2015 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5759722
28 October 2015 Damage Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5752344
19 October 2015 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5764003
7 October 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5737314
1 October 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5734170
28 September 2015 Type not recorded
No type recorded · Activities Europe · Activity 5745573
1 September 2015 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5231996
28 August 2014 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4967650
30 May 2014 MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection · DAPI Audit · Ballast Water Examination · ACP Annual Oversight · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4875907
13 May 2014 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4857575
14 May 2012 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4311432
10 August 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4111316
16 October 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3867834
25 February 2009 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3422284
25 April 2008 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3189736
25 April 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3192493
20 February 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3148022
8 January 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2852341
9 October 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2796840
10 December 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2549367
6 December 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2547240

Deficiency record · 35

01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 17 February 2022 Resolved
Vessel is operating without full crew compliment. 1 x QMED has been removed from duties due to medical casualty.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2022
Resolved 16 March 2022
Resolution: Vessel is back at full compiment.
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 May 2018 Resolved
Nonmetalic expansion joints must be examined at each periodic inspection and replaced 10 years after placed into service. Found joints fatigued and deteriorated on starboard side, port side and center generators.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 23 August 2018
Resolution: Condition of class issued by LR. Components are being replaced as soon as parts arrive onboard.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 31 May 2018 Resolved
Load Line Certificate Record of Assessment sketch page is not filled out with sketch, plan or diagram of locations of doorways in superstructures, exposed machinery casings and deckhouse protecting openings in freeboard and superstructure decks. Complete page 2 diagram and place on vessel withing 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 16 July 2018
Resolution: Rcv'd satisfactory report from Class. Item cleared
Communications › Alarms/Indicators › General Alarm
Issued 22 May 2017 Resolved
The general alarm enunciator tree located in the aft steering compartment was not working. Make repairs to the satisfaction of the class surveyor or attending marine inspector.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 24 May 2017
Resolution: General alarm enunciator tree located in the aft steering room has been repaired and satisfactorily tested.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 17 April 2016 Resolved
The #2 Life Boat/Rescue Boat rudder does not fully swing to starboard as designed. Temporary repairs to rudder cable assembly are satisfactory. Class to attest to satisfactory repairs before vessel sails Internationally.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 April 2016
Resolution: Rudder repair was inspected and tested sat to the satifaction of the attending marine inspectors.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 17 April 2016 Resolved
Provide tech report ensuring that the Vessel Data Recorder is fully operational. Class to attest to satisfactory repairs before vessel sails Internationally.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 April 2016
Resolution: New VDR system was installed in Beaumont. it was tested and a satisfactory VDR performance test was performed. VDR report is scanned in.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 April 2016 Resolved
Ensure that all Maritime Medical Access Medicine Inventory as recommended for medicines and equipment of the International Medical Guide for Ships on board the vessel are up to date. There are currently numerous medicines on inventory that are expired or missing. To be completed prior to sailing International.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 April 2016
Resolution: All outdated items in inventory have been replaced.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 17 April 2016 Resolved
Make permanent repairs to Fixed Fire Detection System short circuit isolator in way of Sec 3 as indicated by three way fault on bridge panel. Provide tech report or class survey attesting to a fully operational system without faults/failures after new isolator is installed. Prior to sailing from next port of call.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 April 2016
Resolution: Fixed fire detection system was shown to be operational and system was tested satifactory for the attending marine inspectors.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 17 April 2016 Resolved
Swap both Life Boat’s male and female electrical shore tie fittings to remove shock hazard (Hazards is when shore tie is unplugged).
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 23 April 2016
Resolution: The male and female ends were swapped removing the risk of electric shock.
Lifesaving › Lifeboat Equipment › Electric Torch
Issued 17 April 2016 Resolved
Both Life Boat flash lights were found in poor condition when using main and spare batteries. Place the required type flash light on board both vessels with spare cells and light bulbs as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 23 April 2016
Resolution: Two flashlights and spare batteries were demonstrated to operated to the requiments of the relavant classifaction society and Marine Inspectors.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 17 April 2016 Resolved
The wire run through overhead in the bridge electrical equipment room (gyro room) is not properly sealed from weather. Seal area as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 9 May 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 April 2016 Resolved
Replace severely corroded J-Box in way of the mechanical exhaust fan for #1 Sanitary Room. Also replace broken grounding wire.
Condition: Improper/Lack of Maintenance
Due 21 June 2016
Resolved 21 June 2016
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 17 April 2016 Resolved
Update all manuals on board the vessel (and Life Boats) and train the crew in regard to the new Life Boat retrofit releasing mechanisms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 9 May 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2016 Resolved
The port and starboard navigational light screens are painted with gloss black paint. Re-paint so that they are matt black screens.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 9 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 April 2016 Resolved
Remove dead end wiring or properly terminate in J-box in the bridge electrical equipment room (gyro room).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 9 May 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 17 April 2016 Resolved
Replace all cracked/dry-rotted hoses on low pressure Co2 refrigeration systems.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 April 2016 Resolved
Remove all gear in the 5 Deck egress/exit trunks. Trunks are common spots for chairs, line, tie downs, rags, and other rubbish.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 April 2016
Construction/Loadline › Markings › Load Line Mark
Issued 17 April 2016 Resolved
Re-mark the hull Load Line markings with contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 17 April 2016 Resolved
Submit repair plan to USCG detailing restoration proposal of all locking arms and doors for the top deck ventilation covers. Plan should address the following locations first because the doors are presently secured using tie downs straps: H36 stbd, H35 stbd, H29 aft, H30 aft, H 27 port, and cover near Fire Station #23 starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 23 April 2016
Resolution: Received detailed plan. Deficiency is cleared but I will stay up on project completion which estimated to be in June.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 17 April 2016 Resolved
Make permanent repairs to or remove the UPS transitional power source.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 21 June 2016
Resolution: This deficiency is closed for DNV-GL is tracking this closely.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 April 2016 Resolved
Properly secure the AC panel in way of the unit on the starboard side flying bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 9 May 2016
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 April 2016 Resolved
Make permanent repairs to vessel’s evaporator/water maker. The vessel’s Water mist firefighting system potable water tank feed was found particularly low. Combined with typical water usage and the lack of water making capabilities, firefighting could be in jeopardy on worst case scenario day.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 24 April 2016
Engineering › Lubricating Oil Service System › Pump
Issued 30 October 2015 Resolved
Class surveyor found a crack on the upper flange of the delivery elbow of the #1 MDE L/O pump. Crack to to be repaired with approved repairs or replaced.
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 24 December 2015
Resolution: Class report was received.
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 October 2015 Resolved
The vessel's 3GHz (10cm S band) radar is currently inoperable. The only other operation radar aboard is the 9 GHz (3cm X band). Prior to departure from port, proper repairs and testing must be carried out on the radar.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2015
Resolution: Radars were checked and were satisfactory.
Engineering › Lubricating Oil Service System › Valve
Issued 7 October 2015 Resolved
Plastic stuffing gland used in place of original metal component
Action required: 705 - Other - as specified
Due 7 November 2015
Resolved 24 December 2015
Resolution: Class report was received.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 30 May 2014 Resolved
Repair window in crews stateroom "OMV-2". Repair prior to sailing foreign.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 June 2014
Resolution: Window was replaced...
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 30 May 2014 Resolved
Properly vent dryer in Laundry room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 3 June 2014
Resolution: Corrected.
Construction/Loadline › Structures › Door
Issued 30 May 2014 Resolved
Properly adjust self-closing device to work shop door in E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 3 June 2014
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 30 May 2014 Resolved
Properly mount fire extinguishers in CO2 room and Dry stores.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 3 June 2014
Resolution: Extinguisher were relocated to it proper placed (Fire Control plan verified).
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 30 May 2014 Resolved
Properly repair CO2 and general alarm panel, starboard side E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 3 June 2014
Resolution: Repaired.
Construction/Loadline › Structures › Door
Issued 30 May 2014 Resolved
Ensure class addresses cracking IWO super structure doors.
Condition: Improper/Lack of Maintenance
Due 5 September 2014
Resolved 9 September 2014
Resolution: Welding Complete
Communications › Alarms/Indicators › Refrigerated Spaces Alarm System
Issued 30 May 2014 Resolved
Properly repair man in freeze alarm in meat locker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 3 June 2014
Resolution: Repaired and tested.
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 May 2014 Resolved
Make permanent repairs or replace salt water piping IAW of #2 cooler STBD side. Additionally, a condition of class will be imposed by class (DNV). Temporary repair was authorized and tested until the vsl return from its foreign voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 September 2014
Resolution: Pipe replaced
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 August 2011 Resolved
LOD 14-11 issued for an inoperable S-band radar. Restrictions: a) Should the primary radar become inoperative, your vessel may transit during daylight hours only. b) If visibility drops below 10 nautical miles; an additional licensed deck officer shall be assigned on the navigating bridge. c) If visibility decreases below that acceptable to the pilot, your vessel must anchor at the first available
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2011
Resolved 12 August 2011
Resolution: Received Class report for proper repairs.
Construction/Loadline › Markings › Load Line Mark
Issued 25 February 2009 Resolved
During Panama Canal transit the Starboard side Loadlines were sheared off. Welded Marks are no longer attached, but oringinal placement is still visible. Paint has also been worn off during transit. ILLC 1966 (2003 Con.) 50 (a)
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 20 April 2009
Resolution: Load line has been re-installed on starboard side according to the International load line certificate. Deficiency rectified.

Casualty record · 11

5 August 2013Routine · role: Involved in a Marine Casualty · activity 4694082
28 September 2015Routine · role: Involved in a Marine Casualty · activity 5745573
19 October 2015Routine · role: Involved in a Marine Casualty · activity 5764003
7 April 2016Routine · role: Involved in a Marine Casualty · activity 5849331
14 April 2016Routine · role: Involved in a Marine Casualty · activity 5854375
6 August 2016Routine · role: Involved in a Marine Casualty · activity 5969736
13 November 2016Routine · role: Involved in a Marine Casualty · activity 6040918
25 October 2020Routine · role: Involved in a Marine Casualty · activity 7084076
16 February 2022Routine · role: Involved in a Marine Casualty · 1 injured · activity 7399645
14 September 2023Routine · role: Involved in a Marine Casualty · activity 7812637
14 July 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7989166
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.