Records from 2006 to 2025. Most recent: inspection, 27 October 2025.
Documentation record
Registered dimensions (L × B × D)368.0 ft × 76.0 ft × 42.0 ft
Registered tonnagegross 9,641 / net 2,892
ITC dimensions (L × B × D)368.0 ft × 76.0 ft × 42.0 ft
ITC tonnagegross 9,641 / net 2,892
BuilderATLANTIC MARINE, INC. · MOBILE, AL, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 February 2026 · expires 31 March 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9641 - Convention (Subpart B), Gross Ton
2892 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 48
27 October 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8259115
13 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8158551
12 November 2024
ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8033362
30 January 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7848610
26 January 2024
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7857308
1 June 2023
ACP Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7720000
31 May 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7701631
8 November 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7591199
8 November 2021
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7344050
1 October 2021
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7327881
18 February 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7142587
5 February 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7136493
29 July 2020
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7019611
11 June 2019
Administrative Inspection · ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6710339
7 June 2019
Administrative Inspection · ACP Drydock Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6710298
17 September 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6542361
5 July 2018
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6467352
8 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6352231
27 December 2017
Examination of Repairs · ACP Drydock Oversight · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6329551
27 November 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6313609
31 October 2017
Excursion Permit
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6298589
27 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6276061
17 August 2017
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6243966
27 May 2016
Periodic Inspection · MTSA/ISPS Verification · In-Service Inspection · ACP COI Oversight · DAPI Audit · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5921630
26 February 2016
Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5822680
25 August 2015
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5226907
14 August 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5218769
10 August 2015
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5211859
6 June 2012
ACP Annual Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4335569
20 February 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4249596
20 February 2012
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4249732
9 November 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3887763
17 October 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3871903
2 March 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3689350
4 May 2009
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3467074
18 April 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3457248
13 April 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3457240
27 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3425543
17 July 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3274586
13 June 2008
MTSA/ISPS Verification · ACP Periodic Oversight · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3238589
24 September 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3064966
25 June 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2985655
22 February 2007
Excursion Permit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2875844
22 June 2006
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2692254
26 May 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2659464
12 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2647654
27 January 2006
MTSA/ISPS Verification · Initial Certification · ACP COI Oversight · Ballast Water Examination · Construction Oversight · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2570328
10 January 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2564028
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 November 2021
Resolved
All hatchway covers shall be weathertight and fitted with gaskets and clamping devices. Gaskets were damaged and not secured in hatch. Clamping devices were missing or in need of repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 10 November 2021
Resolution: Repairs inspected and accepted by RO.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 November 2021
Resolved
Lifebuoys shall be provided with self-igniting lights. Lights found inoperable with expired batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 10 November 2021
Resolution: Repairs inspected and accepted by RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2021
Resolved
All gearing and every shaft and coupling used for transmission of power to machinery essential for the propulsion and safety of the ship or for the safety of persons on board shall be so designed and constructed that they will withstand the maximum working stresses to which they may be subjected in all service conditions, and due consideration shall be given to the type of engines by which they are driven or of which they form part.
Vessel experienced loss of hydraulic fluid to PORT Z-Drive unit (Approx. 200gal reported to NRC). System has been drained as far as practicable, tagged-out, and shaft locked. Conduct proper repairs and testing to satisfaction of Classification Society; ABS acceptance as a condition of class will satisfy deficiency.
The vessel is authorized direct transit only to Bollinger North in Port Fourchon, LA to conduct permanent repairs. Transit is in accordance with the approved route and plan dated 5 Feb 2021. Upon departure and arrival, the vessel shall notify the cognizant OCMI.
Action required: 705 - Other - as specified
Resolved 5 February 2021
Resolution: ABS accepted as condition of class. ABS Work order number: HOM4636495
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 July 2020
Resolved
Where penetrations of watertight bulkheads and internal decks are necessary for access, arrangements are to be made to maintain the watertight integrity. Three watertight doors and one emergency escape hatch had unsatisfactorily installed watertight gasketing, and four doors leading to booster house had loose dogs; gasket material shall be replaced, and adjustments made to dogs such that the doors and hatch are made watertight.
74 SOLAS (14) II-1 / 13-1.1
Class finding number is 829 on work order 4389604
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 5 August 2020
Resolution: Gaskets installed properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2020
Resolved
Flexible hoses must be in accordance with SAE J1942 to minimize hazards; lifeboat winch and port aft davit both had worn flexible hoses. Hoses shall be replaced with approved type.
46 CFR 56.60-25(b)
Class finding number is 829 on work order 4389604
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 5 August 2020
Resolution: Hoses replaced
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 July 2020
Resolved
Stairways which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. Two self-closing doors were not latching properly.
74 SOLAS (14) II-2 / 9.2.3.4.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 30 July 2020
Resolved 30 July 2020
Resolution: Crew adjusted doors and proved satisfactory in the presence of MIs
Lifesaving › Launching Appliances › Davit
Issued 21 August 2017
Resolved
Per model and type approval noted on the launching appliance, system is not approved for dual(rescue boat/davit launched LR)service. Provide objective evidence/documentation showing davit, winch and hook is approved for dual service to the satisfaction of USCG and Class. 74 SOLAS III/31.1.2.2 and III/4.1. See narrative for additional details.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 8 February 2018
Resolution: CG-ENG4 has approved the Launching Appliance -Davit via Case-by-case approval ltr dated NOV 15,2017, CORR 2017-0941. See attached approval ltr. Rescue boat davit hook verified by ABS to be Ned-Deck CAR 35 off-load release type, approval #160.170/EC2690
Lifesaving › Launching Appliances › Davit
Issued 21 August 2017
Resolved
Hydraulic slewing motor on the installed davit inoperable. Make repairs and demonstrate proper operation of the davit slewing system to the satisfaction of the certificate issuing authority.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 26 September 2017
Resolution: ABS surveyor witnessed a satisfactory repair and operational test of the slewing capabilities of the rescue boat davit's slewing motor.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 August 2017
Resolved
Emergency lighting fixture at the portside life raft station not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 21 August 2017
Resolution: Corrected on the spot. Light bulb replaced and tested.
Engineering › Non-conventional Propulsion/Steering › Gear Shaft (z-drive)
Issued 17 October 2010
Resolved
Vessel is to proceed to Mobile, AL and notify USCG Sector Mobile upon arrival. Repairs shall be conducted to the Z-drive unit to the satisfaction of class (ABS).
Action required: 705 - Other - as specified
Resolved 31 May 2011
Resolution: Repair carried out during earlier activity.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 February 2009
Resolved
Secondary Marine Radar (3cm) inop
Condition: Unknown
Due 6 March 2009
Resolved 2 March 2009
Resolution: Rcvd tech report that RADAR is working properly