Records from 2019 to 2026. Most recent: inspection, 20 May 2026.
Documentation record
Registered dimensions (L × B × D)40.1 ft × 12.4 ft × 5.6 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHE TALARIA COMPANY LLC · TRENTON, ME, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 8 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
20 May 2026
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8373162
12 February 2026
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8310030
21 October 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8016145
26 September 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8009246
23 May 2024
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7918023
13 May 2024
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7911510
6 November 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7818739
22 November 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616702
25 October 2022
Hull Examination · In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7562780
1 March 2022
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7403634
6 December 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7360303
29 January 2021
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7153259
3 December 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7105603
3 November 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7077829
8 June 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6970963
18 October 2019
Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6837318
29 January 2019
In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6616813
3 January 2019
Initial Certification · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6610067
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 21 October 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions for heavy weather were missing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2024
Resolved 28 October 2024
Resolution: Add instructions for heavy weather
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel reps were unable to provide evidence that monthly inspections were conducted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2024
Resolved 28 October 2024
Resolution: Added monthly inspection log of fire extinguishers
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2024
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Retroreflective tape wasted on life jacket.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2024
Resolved 28 October 2024
Resolution: Replaced retroreflective tape
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 November 2023
Resolved
Repair Engine Room hatch, gasket, latch, and hinges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2023
Resolved
Replace anchor light and transom stern light. Restricted to day ops.
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 November 2023
Resolved
Provide COD renewal copy to USCG.
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 November 2023
Resolved
Provide IBA servicing report to USCG
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 November 2023
Resolved
Update vessel's copy of MIS report.
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2023
Resolved
Replace ring life buoy and all lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2023
Resolved
Correct port side jet drive shaft leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2023
Resolved
Correct starboard side steering shaft water leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2023
Resolved
Starboard jet sensor is disconnected and missing. Repair/replace water jet oil sensor.
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Attending MI ([name withheld]) is no longer stationed at Sector Miami, and this activity has been left open. We verified with vessel owner that on 20Dec2024 all items where then completed by [name withheld] deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel self-reported damage at stem due to collision with sea wall as a result of STBD bucket malfunction. Make appropriate repairs to bucket, notify OCMI to conduct Sea Trials.
46CFR176.700
Action required: 10 - Deficiency Rectified
Resolved 4 March 2022
Resolution: MIs verified repairs and conducted a satisfactory sea trial.