Records from 2016 to 2026. Most recent: inspection, 26 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 53
26 January 2026
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299701
10 November 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8032788
26 September 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8009576
17 March 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7881054
22 February 2024
MTSA/ISPS Verification · MSP Periodic Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7868536
14 September 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7794418
25 May 2023
MSP COI Oversight · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7647086
22 February 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640563
22 February 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640570
16 January 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7627225
21 November 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7597733
21 November 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7623835
21 September 2022
MSP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7557212
2 September 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7605153
22 August 2022
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7540370
29 June 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7545877
18 January 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7382154
7 January 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7382803
11 December 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7367101
7 December 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7363881
5 December 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7362774
1 December 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7361093
30 August 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7300465
26 August 2021
MSP Annual Oversight · MSP Select Handover Survey · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7296986
25 August 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7311616
12 July 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7258425
10 July 2021
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7255338
9 July 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7250221
26 November 2020
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7102310
27 October 2020
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7085942
8 September 2020
Internal Structural Exam · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7052602
14 June 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7025921
10 March 2020
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6923653
29 February 2020
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6918039
13 February 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6908883
5 January 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6883123
3 January 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6882197
1 September 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6803160
29 August 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6842096
28 August 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6797030
25 August 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6829941
16 July 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732646
24 June 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6723548
10 February 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6626194
7 August 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6511181
23 July 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6488565
21 July 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6486062
20 July 2018
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6485169
6 July 2018
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6469896
29 June 2018
MSP Initial Reflag · Initial Certification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6438392
4 June 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6434354
30 May 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6429591
30 August 2016
ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5986352
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 September 2024
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessel lost propulsion and was unable to restart main engine while underway en-route Los Angeles - Long Beach.
74 SOLAS 2004 II-1/31.1 Code 60ac
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 October 2024
Resolution: Received condition of class from DNV.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported a loss of propulsion due to low lube oil pressure in main engine. Vessel is required to have repairs approved to the satisfaction of an attending CLASS and Coast Guard inspector prior to movement from berth.
74 SOLAS (20) I/11
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 November 2022
Resolution: Receieved satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 September 2022
Resolved
Ducts with a free cross-sectional area exceeding 0.075 m2 shall be fitted with fire dampers ... shall operate automatically, but shall also be capable of being closed manually. STBD AFT E/R supply fire damper did not close on initial testing and after attempting to fix is still not fully closing.
74 SOLAS(2014 Consl)
II-2/9.7.3.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2022
Resolution: Vessel provided class report attesting to the working order and full closure for the STBD Aft fire damper.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 21 September 2022
Resolved
Fire-fighter's outfits shall comply with the Fire Safety Systems Code. Vessel is equipped with 4 sets of fire-fighting outfits and is missing one "axe with handle" and one "harness or seperate belt" for a lifeline.
74 SOLAS(2014 Consl)
II-2/10.10.1.1
FSS Code Chapter 3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 4 October 2022
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 21 September 2022
Resolved
All alarms must ... Audibly annunciate until manually acknowledged. Alarm panel in Steering Gear room does not have functioning audible alarm. Visual is working.
46 CFR 62.25-20
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 September 2022
Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. A-60 self-closing door to Fuel Oil Purifier room found not able to self-close and latch properly.
74 SOLAS (14 Consl)
II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 December 2021
Resolved
Where remote control of propulsion machinery from the navigation bridge is provided, the following shall apply: the speed, direction of thrust and, if applicable, the pitch of propeller shall be fully controllable from the navigation bridge under all sailing conditions, including maneuvering. Operator notified OCMI of a failure of the M/E governor controller. At thi time vessel has no use of remote control from the bridge or engine coontrol room, and can only operate the engine in local control. Provide class report attesting to satisfactory repairs.
Action required: 15 - Rectify deficiencies by next port
Resolved 13 December 2021
Resolution: Received class report (attached).
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 30 August 2021
Resolved
Each vessel of 10,000 gross tons or more must have, in addition to the radar system under &164.35(a), a second marine radar system that operates independently of the first.
Vessel's secondary marine radar inoperable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2021
Resolution: Received tech report for repair of radar.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 August 2021
Resolved
Where risk from over speeding of machinery of machinery exists, means shall be provided to ensure that the safe speed is not exceeded. Vessel could not demonstrate overspeed trips for its ship service generators. Vessel is to prove operation of overspeed trips for all 4 ship service generators.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2021
Resolution: Witnessed proper operational test for overspeed shutdowns on all 4 SSDG's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 August 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port side lifeboat AFT & FWD traveling fall missing a cotter pins for locking bolt/nut.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 August 2021
Resolved 26 August 2021
Resolution: Vessel installed two new cotter pins in bolts.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2021
Resolved
Not less than one half of the total number of lifebuoy shall be provided with lifebuoy self-igniting lights complying with the requirements of par. 2.1.2 of the Code. Ring buoy light on Port side midship not properly illuminating.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 August 2021
Resolved 26 August 2021
Resolution: Vessel installed new light, op tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 August 2021
Resolved
Periodic safety tests must demonstrate the proper operation of the primary and alternate controls, , alarms, power sources, transfer interlocks and safety controls. Test for overspeed shutdowns for the SSDG's could not be conducted IAW approved PSTP's. Vessel is to demonstrate overspeed shutdowns of SSDG's IAW approved PSTP's or revise PSTP's.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2021
Resolution: Received amended PSTP's with updated procedures for SSDG's overspeed trips.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2020
Resolved
The condition of the ship & its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The emergency lighting located along the deck on both port and stbd sides and behind paint locker were found to be inoperable. Prove proper operation of emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 10 September 2020
Resolution: Corrected and verified by DNV-GL. Class report G130174.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 September 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The isolation valve for the port side fire main hydrant located at frame B14 was found to be inoperable. Prove proper operation of isolation valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 10 September 2020
Resolution: Corrected and verifed by DNV-GL. Class report G130174.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 August 2019
Resolved
The arrangements provided shall be such as to ensure that the safety of the ship in all sailing conditions, including maneuvering, is equivalent to that of a ship having the machinery spaces manned. The vessel experienced "fail to start" alarms with no response from the main engine from both bridge and engine room control room main engine controls.
The engine room must be fully manned, and personnel ready to take local control to respond to engine orders from the bridge when operating in all pilotage waters, when entering and departing ports, and when maneuvering within ports.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 1 September 2019
Resolution: Vessel superintendent sent MI tech reports and class surveyor report demonstrating tests conducted proving the satisfactory operation of the vessel's propulsion system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2019
Resolved
Provide electrical insulating mats in front of HVSC switchboard.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 16 July 2019
Resolution: Corrected while aboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 July 2019
Resolved
Provide sufficient fuel for the emergency air compressor. The fuel tank was empty.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 16 July 2019
Resolution: Corrected while aboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 July 2018
Resolved
Satisfactory means permanently attached shall be provided for closing the opening of the air pipes. MI found missing closing dogs, and cotter pins on closing devises for air pipes and vents throughout the vessel.
(Vessel has 60 days to complete this item)
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 4 August 2018
Resolution: Received satisfactory survey report from DNV-GL.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 2 July 2018
Resolved
Subject to the provisions of paragraphs 8.2 to 11.2 contracting governments shall be able to receive long-range identification and tracking information about ships, for security and other purposes. Vessel needs to provide conformance test report for LRIT.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 23 July 2018
Resolution: Passing LRIT conformance test results provided to OCMI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2018
Resolved
The alarm shall operate for the length of time needed to evacuate the space, but in no case less than 20 seconds. It takes approximately 60 seconds to evacuate the engine room.
FSS 5.2.1.3.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 11 July 2018
Resolution: Received tech report from GFS attesting to proper time delay length of 60 sec.