Records from 2012 to 2026. Most recent: inspection, 10 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
10 April 2026
Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8334339
10 June 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8156617
10 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8081475
29 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7899466
17 April 2023
Deficiency Check · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7654577
13 August 2022
Type not recorded
No type recorded · STATION ST LOUIS · USCG Heartland District (CGD-H) · Activity 7535207
27 April 2022
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7417221
5 May 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7190094
6 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6998712
3 June 2019
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6702516
11 April 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6660633
26 October 2018
Drydock Exam · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6569035
21 August 2018
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6680467
21 May 2018
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6428252
18 July 2017
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6212863
17 June 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6183168
4 April 2017
Annual Inspection · Plan Review "T" Boat · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6117685
15 September 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5989294
17 June 2016
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5893544
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 April 2026
Resolved
Any vessel of at least 5 net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. COD expired on 28FEB2026.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: Valid COD on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2026
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Floating waterlight was inoperable.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: Operable waterlight on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 April 2026
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Three flares were found to be expired.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: 6 qualifying distress signals on boad vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 April 2026
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Prove annual servicing of portable fire extinguishers was completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: Documentations provided and accepted showing required annual servicing of portable extinguishers had been completed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 April 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit was unopened and labeled as being expired by manufacturer.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: A new first aid kit within expiration date was on board vessel.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 April 2026
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Fire buckets were missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: 3 fire buckets with lanyards and properly labeled were on board vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 March 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Found numerous items to be expired. Replace prior to passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2025
Resolution: Received a photo of new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. (3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Floating water light was not properly stowed and configured incorrectly with buoy; battery was expired and light was inoperable.
705 - Restricted to daylight operation
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 June 2025
Resolution: Received a photo of correctly configured ring buoy with lifeline and light. Also received a photo of new battery for floating light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 March 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets. Vessel had 3 1/2 gallon buckets. Drill drain holes at 2 1/2 gallon mark.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2025
Resolved 30 June 2025
Resolution: Received picture of 5-gallon fire buckets with holes drilled at the 2.5gal mark.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2024
Resolved
46 CFR 180.20(d)
A vessel must carry one floating water light, unless it is limited to daytime operation.
Battery for floating water light expired. Vessel is restricted to daytime operations until rectified.
Action required: 705 - Other - as specified
Due 1 July 2024
Resolved 17 June 2024
Resolution: received photo of new battery
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2024
Resolved
46 CFR 179.360
A vessel of more than 26' but less than 65' must carry a minimum of one life buoy of not less than 24" in diameter.
Life buoy grab lines were dry rotted, need to replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2024
Resolved 17 June 2024
Resolution: Received photo of new ring buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 April 2024
Resolved
46 CFR 179.360
A hatch exposed to the weather must be watertight.
Gasket on center bilge hatch needs to be replaced or reinstalled to ensure proper seal when closed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2024
Resolved 17 June 2024
Resolution: Gasket was reinstalled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2023
Resolved
The life ring buoy light is hanging by a clip from the buoy. Properly stow the life ring buoy light in a bracket and stow the life ring buoy, light and thr in accordance with 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. The COI allows for 13 pax and 01 crew. There are 13 serviceable life jackets on board. Vessel restricted to 12 pax and 01 crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 April 2023
Resolved
Conduct and log crew training and drills to include fire drill, man overboard drill and abandon ship drill in accordance with 46 CFR 185.512, 185.520 and 185.524.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 April 2023
Resolution: The deficiency was cleared to the satifaction of an attending USCG Marine Inspector
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 April 2023
Resolved
Four of the six required flares on board were expired. Replace the expired flares with new prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2023
Resolved
Prove proper operation of the forward bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 May 2021
Resolved
Conduct and log crew training and drills to include fire drill, man overboard drill, and abandon ship drill in accordance with 46 CFR 185.512, 185.520, and 185.524.
Action required: 10 - Deficiency Rectified
Due 19 May 2021
Resolved 19 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 May 2019
Resolved
Troubleshoot and repair vessel's pre-engineered noraml/override functionality switch. After engine shutdown, engine should not be able to restart in normal mode.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 3 June 2019
Resolution: Deficiency cleared to the satisfaction of a USCG marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 May 2019
Resolved
Troubleshoot and repair the engine compartment aft bilge pump visual indicator light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 3 June 2019
Resolution: Deficiency cleared to the satisfaction of a USCG marine inspector.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 9 May 2017
Resolved
Vessel certificated for 13 passengers using seat criteria, however, vessel seating currently sufficient for only 12 passengers. Until sufficient seating is properly installed to accommodate a 13th passenger, maximum passenger count is limited to 12.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 24 May 2017
Resolution: New fixed seat installed and examined by marine inspector.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 June 2016
Resolved
Certificate Expired. Valid COD required prior to vessel operation.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 7 July 2016
Resolution: Reviewed MISLE vessel history and found a new COD with coastwise service issued 07JUL2016 for vessel.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 June 2016
Resolved
Demonstrate proper operation of pre-engineered fixed fire fighting system as required by 46 CFR 181.420(a)&(b) prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 15 September 2016
Lifesaving › Hand Flares › Quantity
Issued 17 June 2016
Resolved
Vessel required to have 3 flares and 3 smoke devices, or 6 flares. Vessel only had 4 flares on board. Prior to carrying passengers, vessel required to have correct number of signaling devices.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 15 September 2016
Resolution: Proper number of approved flairs on board.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 17 June 2016
Resolved
Two adult PFDs not marked with vessel name. PFDs removed from service until properly marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 15 September 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 June 2016
Resolved
Items in First Aid Kit expired (aspirin, burn ointment, and eye wash). Items required to be replaced with non-expired items prior vessel carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 15 September 2016
Personnel › Training › Passenger Safety
Issued 17 June 2016
Resolved
Conduct crew training on duties expected to perform in an emergency (listed in 46 CFR 185.510: man over board, heavy weather, and fire fighting) prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 15 September 2016
Lifesaving › Lifebuoys › Serviceable
Issued 17 June 2016
Resolved
Lifebuoy (ring) not marked with retroreflective material. Prior to vessel operating with passengers, lifebuoy must be marked with approved Type II material applied as specified by IMO Resolution A.658(16).
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 15 September 2016
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 June 2016
Resolved
Post lifejacket instructions placard prior to operating with passengers. Vessel carried two styles of adult PFDs. Posted placard applied to only one style.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 15 September 2016