MAURY USCG vessel records Sign in
← All vessels

SEA HARMONY

SEA HARMONY is a 2005 freight ship. The Coast Guard has recorded 9 inspections since 2007, most recently in April 2016, along with 5 deficiencies and 3 operational controls.

Records from 2007 to 2016. Most recent: inspection, 21 April 2016.

Built
2005
Last inspected
21 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9339791 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
801699
Flag
PANAMA
—
Maury page id
psix-801699

Inspections, by type

…with no type recorded4
Years with a record 5 calendar years (2007–2016)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16960 - Convention (Subpart B), Gross Ton
10498 - Convention (Subpart B), Net Ton
34593 - Displacement, Ton
28409 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

21 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5859135
26 December 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5787348
5 February 2010 Ballast Water Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3672458
2 February 2010 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 3673051
4 June 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3225396
24 March 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3170163
23 March 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3169681
23 March 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3171585
23 November 2007 Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3097688

Deficiency record · 5

Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 26 December 2015 Resolved
PSCO noted excessive oil and oil residue IWO the vessel's waste oil tank.
Action required: 705 - Other - as specified
Due 9 January 2016
Resolved 8 January 2016
Resolution: Received class report attesting to rectification.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 26 December 2015 Resolved
Mechanical seal on Emergency Fire pump has excessive leak and needs replacement.
Action required: 705 - Other - as specified
Due 9 January 2016
Resolved 8 January 2016
Resolution: Received class report attesting to rectification.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 26 December 2015 Resolved
Portable CO2 fire extinguisher in galley is not the size indicated on the fire control plan. Extinguisher provided is a 5kg, but plan calls for a 6.8kg.
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 21 April 2016
Resolution: RCVD ClassNK report attesting to rectification of above deficiency.
Lifesaving › Lifeboat › Markings
Issued 26 December 2015 Resolved
PSCO noted that the retro reflective tape is missing or worn on both lifeboats.
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 21 April 2016
Resolution: RCVD ClassNK report attesting to rectification of above deficiency.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 24 March 2008 Resolved
Vessel experienced a power loss while transiting the Lower Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2008
Resolved 24 March 2008
Resolution: Received proper documentation from Nippon Kaiji Kyokai satisfying requirement.

Ownership record