MAURY USCG vessel records Sign in
← All vessels

LION

LION is a 2000 freight ship. The Coast Guard has recorded 42 inspections since 2006, most recently in October 2017, along with 8 deficiencies and 13 operational controls.

Records from 2006 to 2017. Most recent: inspection, 18 October 2017.

Built
2000
Last inspected
18 October 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9208356 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA3172
802273
Flag
MALTA
—
Maury page id
psix-802273

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (2006–2017)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it19131 - Simplified, Gross Ton
19131 - Convention (Subpart B), Gross Ton
10095 - Simplified, Net Ton
25331 - Dead Weight, Ton
10095 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

18 October 2017 COE-Dockside · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6290006
17 September 2017 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6291618
13 September 2017 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6265802
25 August 2017 COE-Dockside · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6251402
2 August 2017 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228034
14 July 2017 ISPS II Exam · COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6208964
21 June 2017 COE-Administrative · COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6182471
31 May 2017 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6161120
14 May 2017 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6144887
19 April 2017 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6128381
30 March 2017 COE-Dockside · COE-Administrative
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6114615
10 March 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6102380
7 March 2017 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6100243
23 February 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6093445
15 February 2017 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6088832
2 February 2017 NPV Safety Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6081411
23 January 2017 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6075058
12 January 2017 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6067891
21 December 2016 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6061053
6 December 2016 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6051625
9 November 2016 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6038525
23 October 2016 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6025468
2 October 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6014047
28 September 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6011641
11 September 2016 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5994487
21 August 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5974483
27 July 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5954528
10 July 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5931370
19 June 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5907423
29 May 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5886478
29 May 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5894232
5 May 2016 ISPS I Exam · COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5869965
4 May 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5868729
13 April 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5853175
8 April 2016 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5850097
31 March 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5841127
31 March 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5841792
30 March 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5843398
4 February 2009 PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3412416
30 July 2008 Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3283890
24 February 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3152461
11 August 2006 ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2739391

Deficiency record · 8

Engineering › Fuel Oil Service System › Filter
Issued 2 February 2017 Resolved
The arrangements for the storage, distribution, and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. PSCO discovered MDE fuel oil supply strainer leaking, gasket needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 February 2017
Resolved 23 February 2017
Resolution: Received class report attesting to MDE fuel supply station and observed no further leaking.
Fire Fighting › Means of Escape › Doorways
Issued 2 February 2017 Resolved
Fire doors shall be self closing and be capable of closing against an angle inclination of up to 3.5 degrees opposing closure. Fire door to escape trunk in engine room does not seat fully when released and needs to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 February 2017
Resolved 23 February 2017
Resolution: Received class report attesting to the fire door being capable of self-closing.
Engineering › Steering Gear System › Rudder Stock
Issued 2 February 2017 Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over from 35 degres on one side to 35 degrees on the other side. Rudder does not travel from 35 to 35 (only goes to 32 degrees) and needs to be readjusted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 23 February 2017
Resolution: DNV-GL issued Condition of Class until 04MAR2017.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 31 March 2016 Resolved
0950 - Electric equipment in general - All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. 06 circuit breaker handles in the engine control room were found broken and replaced with crews. 74SOLAS(04)II-1/45.1.3
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 March 2016
Resolved 8 April 2016
Resolution: Received Class Report giving the vessel a condition of class to have circuit breaker handles replaced by 01JUN2016(see documents).
Lifesaving › Launching Appliances › Davit
Issued 31 March 2016 Resolved
0820 - Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off power before the davit arms reach the stops. The safety device on the rescue boat's davit was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 31 March 2016
Resolution: Corrected on the spot.
Fire Fighting › Means of Escape › Doorways
Issued 4 February 2009 Resolved
Doors in machinery space adjacent/in to oil purifying room are not self-closing. Provide self-closing device to doors in accordance with fire control plan. (Frame 23-24, starboard side).
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2009
Resolved 27 May 2016
Fire Fighting › Ventilation Systems › Smoke Extraction System
Issued 4 February 2009 Resolved
Fire damper above emergency generator does not close completely. Fix/replace and prove proper operation to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2009
Resolved 27 May 2016
Lifesaving › Lifeboat Equipment › Food Ration
Issued 4 February 2009 Resolved
Lifeboat equipment not present/operable. Provide enough food rations for each crew member prior to departure. (Provide receipt to USCG)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2009
Resolved 5 February 2009
Resolution: Received faxed copy of purchase recipt of 11 food rations.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.