Records from 2016 to 2023. Most recent: inspection, 29 November 2023.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 16
29 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7830521
1 May 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7679016
2 May 2022
COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7442138
29 November 2021
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7358793
21 July 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7264488
7 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7206571
6 August 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7013190
7 November 2019
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6844879
1 May 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6670812
29 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6428147
7 May 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6407808
21 November 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6309814
11 May 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6138301
8 July 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5938564
17 June 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5914037
11 February 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5810334
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 November 2023
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel drydock was due NLT 30NOV23. COI is invalid.
Action required: 60 - Rectify deficiencies prior to movement
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2022
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 03 life jackets were faded to white and cloth sheathing easily torn. Vessel restricted to 10 passenger capacity until life jackets are replaced.
46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2022
Resolution: Operator replaced 03 life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2022
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. 02 ring buoys need new markings for vessel name.
46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2022
Resolution: Operator replaced vessel name lettering on 02 life rings.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 May 2022
Resolved
Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. 40B:C extinguisher corroded on bottom.
46 CFR 176.810(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2022
Resolution: Operator replaced fire extinguisher and properly mounted it.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 May 2022
Resolved
A vessel must have at least three 2 1/2 gallon buckets... The words “FIRE BUCKET” must be stenciled in contrasting color on each bucket. Fire buckets need to be made to carry only 2 1/2 gallons and be marked "FIRE BUCKET".
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2022
Resolution: Operator modified 5 gallons buckets to only hold 2.5 gallons and labeled each fire bucket IAW regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Missing donning placard for child size life jackets.
46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2022
Resolution: Operator removed 2nd type of life jacket, no longer required to have 02 sets of donning instructions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2021
Resolved
Vessel's Consortium had multiple employees expired. O/O provided updated list for Consortium. Corrected on the spot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2021
Resolution: O/O provided updated list for Consortium. Corrected on the spot. Verified during def check.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 July 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2021
Resolution: Operator completed required training and provided documentation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2021
Resolved
To maintain Single Operator Permit, Owner must provide documentation that each credentialed mariner who operates vessel is able to complete required safety emergencies by themselves.
Action required: 705 - Other - as specified
Resolved 21 July 2021
Resolution: Vessel got underway with additional Captain, completed satisfactory man overboard drill.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2021
Resolved
Each vessel must be equipped with two portable lights. Vessel only had one light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O provided 2 portable lights
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 June 2021
Resolved
Vessels charts and publication were expired. Required to provide up to date charts and pubs
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2021
Resolved 3 August 2021
Resolution: MI's verified updated charts and tide tables.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 June 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O provided valid station license
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 June 2021
Resolved
Vessel's FCC Safety Cert was expired. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O provided valid safety certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2021
Resolved
Labeling of lifejacket stowage containers must correlate to the number of lifejackets stowed in container. Two containers were labeled with 8 but only held 7 lifejackets. Relabel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O correctly labled lifejacket stowage
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 June 2021
Resolved
Vessel's required 3 R and 3 O flares. Flares were expired. Replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O provided new flares
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 June 2021
Resolved
Vessel's first aid kit was expired. Replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2021
Resolved 3 August 2021
Resolution: MI's verified updated first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 August 2020
Resolved
Each floating waterlight must be approved in accordance with 161.010. Found incorrect battery installed in waterlight. Replace with an approved type.
Action required: 705 - Other - as specified
Due 13 August 2020
Resolved 18 August 2020
Resolution: Vessel operator replaced with an approved type battery.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 November 2019
Resolved
Remove epoxy covering weld to make area ready for inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2020
Resolution: Removed epoxy to reveal cracked weld and repaired to satisfaction of attending CGMI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 November 2019
Resolved
Repair engine cover latch and gasket to manufacturer's specification
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2020
Resolution: Observed new engine cover gasket to satisfaction of attending CGMI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 May 2019
Resolved
Port sidelight not in compliance with regulation: displaying improper characteristics. Until corrected vessel may only operate in daytime and fair weather conditions.
46CFR§183.420
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 31 May 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2018
Resolved
Vessel did not have iodine applicators or eye dressings in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 29 May 2018
Resolution: Vessel acquired iodine and eye patches.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 17 June 2016
Resolved
Found employee's not enrolled in consortium. Provide proof of employees enrollment in consortium.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 8 July 2016
Resolution: Provided updated drug consortium.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 June 2016
Resolved
Found First Aid kit not in compliance. Provide proof of items in compliance with 46CFR160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 8 July 2016
Resolution: Provided updated charts.