Records from 2016 to 2025. Most recent: inspection, 8 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 September 2025
Resolved
All persons requiring unescorted access to secure areas of vessels, facilities, and OCS facilities regulated by parts 104, 105 or 106 of this subchapter must possess a TWIC before such access is granted... The deckhand employed at the time of inspection did not hold a valid TWIC card. Vessel may not get underway until full manning is met.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
Resolution: Deckhand was replaced with a TWIC holding crew member.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2025
Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. Emergency lighting in the engine room and passageway was not adequate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
Resolution: Crew replaced required lighting with LED battle lanters that sufficiently lit the escape path.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 September 2025
Resolved
The master shall ensure that storage batteries driving fitted systems for emergency lighting and power are tested at least once each 6 months that the vessel is operated. The navigation lights and bridge navigation equipment were not receiving emergency power.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
Resolution: A UPS was added to the vessel to transition power to the battery system.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2025
Resolved
Each OSV must carry lifebuoys approved under approval series 160.150 or 160.050... Four lifebuoys were found with dry-rotted plugs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
Resolution: Lifebuoys were replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2025
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.112 or 161.012 securely attached to the front shoulder area of the lifejacket.
Two lifejackets were found with expired chem-lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
Resolution: Expired chem lights were replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 September 2025
Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. The previous test of the pressure relief valves was conducted in June 2022.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
Resolution: Vessel replaced safety relief devices with newly bench tested valves.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 September 2025
Resolved
Vent outlets from all tanks which may emit flammable or combustible vapors must be fitted with a single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two screens of at least 20 by 20 mesh spaced not less than one-half inch (13mm) nor more than 1 1/2 inches (38mm) apart. The flame screen on the stbd day tank was wasted and holed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
Resolution: Flame screen was replaced with new.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 September 2025
Resolved
The owner of a vessel to which this section applies shall provide clear and conspicuous signs on board the vessel notifying the crew of the presence of video and audio surveillance equipment. Vessel installed recording system while team was on board, needs to post AV recording placards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 10 September 2025
Resolution: Vessel posted audio/video recording notices around the accomodation space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025
Resolved
Nothing in this subpart limits the marine inspector from making such tests or inspections he or she deems necessary to be assured of the vessel's seaworthiness. Steering test revealed the port steering gear had a hydraulic leak.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2025
Resolved 10 September 2025
Resolution: Crew found leaking from valve, replaced valve and torqued fitting. Leak repaired.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 8 September 2025
No resolution recorded
No OSV that carries flammable or combustible liquid with a flashpoint of below 140 °F (60 °C), or carries hazardous cargoes on deck or in integral tanks, or is involved in servicing wells, may have electrical equipment installed in pump rooms, in hose-storage spaces, or within 3 meters (10 feet) of a source of vapor on a weather deck unless the equipment is explosion-proof or intrinsically safe. Methanol pump motor control is installed within 3m of the methanol box vent. Move control or install eX fixture. Rectify prior to carriage of methanol.
Condition: Improper Installation
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 September 2024
Resolved
There must be ground detection for ships service power system. Switchboard generator read aground of faulty system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2024
Resolved 19 September 2024
Resolution: Ground identified (AC unit) corrected, no grounds present.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 September 2024
Resolved
Each vessel with an operable toilet must have a type II or III. MSD TYPE II on board was not in an automatic functioning mode and once switched over MSD was only partially operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2024
Resolved 19 September 2024
Resolution: MSD serviced. Blower, Chemical pump and float replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2024
Resolved
To operate with a portable tank vessel must have a fire hose fitted with an approved portable mechanical foam nozzle with pick up tube. Pick up tube was inoperable.
705: Vessel cannot carry a portable tanks until there is an operable pickup tube.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2024
Resolution: Eductor replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 September 2024
Resolved
Each general alarm bell must state, "GENERAL ALARM -WHEN BELL RINGS GO TO YOUR STATION." Engine room alarm bell only read, "GENERAL ALARM BELL."
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2024
Resolution: sign placed in engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 October 2021
Resolved
Each lifebuoy must be marked with vessel name and name of the port as marked on the stern; marking was faded on lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 October 2021
Resolution: Ring buoys were freshly marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2021
Resolved
Each grill or similar cooking appliance must have a means to collect grease or fat; range filter was clogged, preventing further collection of grease and presenting fire hazard in galley.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2021
Resolution: Filter was cleaned and free of grease build-up.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 October 2021
Resolved
Ring life buoys must be marked with Type I or II retro-reflective material approved under 46 CFR 164.018; retroreflective tape was degraded and no longer meeting the approval standard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2021
Resolution: New retro-reflective tape was added to the ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 September 2020
Resolved
Lifefloat on starboard side of vsl needs serviced. reflective tape and paddles are cracking
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 October 2020
Resolution: [name withheld] received photo evidence via email that all deficiencies have been rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 September 2020
Resolved
Unused opening in engine room panel, each unused panel should be closed to prevent undue injury.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 October 2020
Resolution: [name withheld] received photo evidence via email that all deficiencies have been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 September 2020
Resolved
Line throwing gun has 05 five used shells.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 October 2020
Resolution: [name withheld] received photo evidence via email that all deficiencies have been rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 September 2020
Resolved
On main deck Port side there is a unused junction box disconnected from the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 October 2020
Resolution: [name withheld] received photo evidence via email that all deficiencies have been rectified.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 August 2018
Resolved
Vessel call sign had been changed but not updated on EPIRB registration. Provide updated EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2018
Resolution: Vessel provided new EPIRB registration with correct call sign.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 7 August 2018
Resolved
Provide functioning sound powered phone in engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2018
Resolution: Verified proper operation of sound powered phone in engine room.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 August 2018
Resolved
Update charts to NTM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2018
Resolution: All charts had been updated to most recent NTMs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2018
Resolved
Replace supply lines to guages on MDEs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2018
Resolution: Supply lines to the fuel gauges had been replaced on both MDEs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 20 July 2017
Resolved
03 P/V valves for Methanol tanks found inoperable. Service and prove proper operation, prior to loading Methanol.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2017
Resolved 31 October 2017
Resolution: New P/V valves installed
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 July 2017
Resolved
Fire, Man Overboard, Abandon Ship, and Security Drills to be conducted prior to vessel getting u/w.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2017
Resolution: CG personnel witnessed Fire, Man Overboard, Abandon Ship, and Security Drills.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 20 July 2017
Resolved
Vessel required to have non-tank vessel response plan per 33CFR155.5015(a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2017
Resolution: Vessel Response Plan on board
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 23 August 2016
Resolved
Rudder angle indicators on the bridge and at the emergency steering station are not operating correctly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2016
Resolved 9 September 2016
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 23 August 2016
Resolved
Ground detection on Bus "A" was not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2016
Resolved 9 September 2016
Resolution: Corrected
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 23 August 2016
Resolved
Emergency Steering procedures not posted at station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 9 September 2016
Resolution: Placard made and installed at aux station.
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 August 2016
Resolved
Lifejacket donning procedures for type on board was missing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 9 September 2016
Resolution: Corrected placards installed.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 23 August 2016
Resolved
Vessel was missing a Coast Guard approved Non-Tank Vessel Response Plan as per 33 CFR 155.5015(a)(4)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2018
Resolution: Vessel has an approved NTVRP.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 August 2016
Resolved
Proper OWS is not installed on board IAW MEPC.60(33)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 9 September 2016
Resolution: OWS was removed.