04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 March 2026
Resolved
Emergency lighting on board vessels less than 100 gross tons must have adequate emergency lighting fitted along the escape route to the main deck from working spaces below deck. Emergency lighting from the engine room to the mess deck were found to be insufficiently bright. Additionally the emergency light at the base of the ladder leading into the corridor to the engine room was non-functioning and in need of repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2026
Resolved 5 March 2026
Resolution: Emergency Lighting was satisfactory placed and lit up all emergency egress pathways in the engine room.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 3 March 2026
Resolved
Offshore supply vessels less than 100 gross tons shall had rudder-angle indicators installed at the control station in the pilothouse. Rudder-angle indicators at the forward and aft control stations in the pilothouse were found unable to indicate rudder angles beyond 30 degrees despite rudders being capable of 45 degrees. Additionally, the pins attaching the rudder arms to the hydraulics were excessively worn and in need of replacement.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2026
Resolved 5 March 2026
Resolution: Steering pistons were replaced and rudder angle indicators were corrected to reflect accurate rudder angle.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 31 January 2025
Resolved
A vessel engaged in commercial service that does not carry passengers shall maintain a video surveillance system. The requirements in this section shall apply to documented vessels with overnight accommodations for at least 10 individuals that are at least 79 feet and required to have a load line. The vessel did not have surveillance cameras installed. Rectify within 7 days.
46 USC 4901
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2025
Resolved 7 February 2025
Resolution: Cameras installed in accordance with 46 U.S.C 4901
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 31 January 2025
Resolved
A vessel subject to inspection under section 3301, such as offshore supply vessels, shall be equipped with a vessel master key control system. The vessel did not have this system installed. Rectify within 7 days.
46 USC 3106
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2025
Resolved 7 February 2025
Resolution: Vessel installed handle with no locks to accomodation spaces.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 31 January 2025
Resolved
Each OSV of less than 100 gross tons must have a rudder-angle indicator. The rudder angle indicator located at the aft steering station on the bridge was not in proper working order. Rectify within 7 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 February 2025
Resolved 7 February 2025
Resolution: Reaplced RAI, conducted steering test, all sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 January 2025
Resolved
Each enclosed space within the vessel must be properly vented and means provided for closing each vent. Vent in CO2 room did not have means for closure. Rectify within
7 days.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 February 2025
Resolved 7 February 2025
Resolution: Installed new bell housing with manual swing sclosure, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 January 2025
Resolved
Each cable and wire must be protected by metal coverings or other suitable means. A grouping of wires above the hydraulic tank next to bow thruster was not secured in a covering. This was corrected prior to inspection team departure.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 31 January 2025
Resolution: Placed loose wiring in a metal box covering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 December 2022
Resolved
Each generator must have overspeed protection. Port generator had faulty speed sensor. Unable to test overspeed.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2022
Resolved 8 December 2022
Resolution: Overspeed test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 December 2022
Resolved
Visible and audible alarms must be provided in pilot house for high bilge level. Bigle alarms for engine room did not have audible alarm in pilot house.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2022
Resolved 8 December 2022
Resolution: Tested bilge alarms and panel sounded on the bridge
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2022
Resolved
Fuel installations shall be protected against excessive movement and vibration. Port generator was missing clamp for high pressure fuel lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 8 December 2022
Resolution: Clamp installed sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 November 2020
Resolved
EMERGENCY ESCAPE HATCH IN THE ENGINE ROOM IS NOT WATERTIGHT.
EACH HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT.
ADJUST HATCH TO MAKE WATERTIGHT.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2021
Resolved 11 December 2020
Resolution: doors and escape hatch were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 November 2020
Resolved
NONMETALLIC FLEXIBLE FUEL RETURN HOSE ON THE STBD GENERATOR WERE DRY ROTTEN AND LEAKING.
FLEXIBLE HOSE INSTALLATIONS MUST BE REPLACED IAW SAE-J 1942 STANDARDS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 8 December 2020
Resolution: Fuel hose was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 November 2020
Resolved
FLOAT FREE LINKS ON LIFE FLOATS WERE THE INCORRECT SIZE FOR THE FLOATS.
LIFEFLOATS MUST HAVE A FLOAT-FREE LINK MEETING THE REQUIREMENTS OF 46 CFR 160 CONNECTING THE PAINTER TO THE OSV.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 8 December 2020
Resolution: float free links were replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 November 2020
Resolved
FLEXIBLE CONNECTIONS ON FIXED CARBON DIOXIDE SYSTEM ARE LOOSE. TIGHTEN CONNECTIONS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 8 December 2020
Resolution: hoses were tightened.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 November 2020
Resolved
WATER HEATER RELIEF VALVE WAS NON FUNCTIONAL. REPLACE
RELIEF VALVE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 8 December 2020
Resolution: water heater relief valve was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 September 2019
Resolved
Each vessel must undergo an annual inspection within three months before or after the anniversary date isted on the COI. Vessel has an anniversary date of 30 March. Inspection was scheduled outside of window.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 30 September 2019
Resolved
Each new vessel over 79ft in length is required to comply with Load Line rules. Vessel is currently over due to its loat line survey and it ILLC on board is not valid.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 September 2019
Resolved
Each door in a watergight bulkhead must be capable of being made watertight. It was noted that all QAWTD and QAWTH had gasket that was severly wasted/detoriorated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2019
Resolved
The Master shall ensure that the vessel's required fire fighting equipment is on board at all times and is always ready for immediate use. 01 fire hose busted during pressure test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 September 2019
Resolved
All lifesaving appliances shall be kept on board at all times and maintained ready for immediate use. One lifefloat was found with a large cracke making it un-servicable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 September 2019
Resolved
Vessel is fitted with high bilge level alarms. Engine room bilge alarm found inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2019
Resolved
Each vessel must have propulsion control systems operable from the pilot house that enable the operator to shutdown each main engine. Vessel does not have means to secure engine from pilot house.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 September 2019
Resolved
All electrical equipment shall be designed, installed, and maintained to protect crew members from electrical hazards. Fresh water solenoid valve found missing cover with exposed wiring presenting hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 September 2019
Resolved
Each battery used in an item of lifesaving equipment must be clarly marked wiht an expiration date and replaced when expired. All floating waterlights on vessel found with batteries expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 September 2019
Resolved
Vessel must have adequate emergency lighting fitted along the path of escape to the main deck. Battery powered emergency lantern in port E/R escape trunk found dead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 30 September 2019
Resolved
Each vessel with fixed pitch propellers must have on the navigation bridge and at the engineroom control station a propeller speed and direction indicator for each shaft. Vessel's shaft tachometers foudn malfunctioning and needing calibration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2019
Resolved
Safety relief valves on pressure vessels must be checked at intervals not exceeding the COI. The safety relief valves in the E/R were not tested and lifting at too low a PSI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 September 2019
Resolved
Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place. Guards over rotating machinery on liquied mud pump is broken presenting a hazard to personnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 September 2019
Resolved
Vessel is required to have a general alarm that operates while on emergency back up power. Vessel's GA is currently not operating on back up power.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2019
Resolved
Non metallic flexible hose must meet SAE J1942 and must not exceed 30 inches in length. Observed the following hoses:
-Wasted fuel oil return hose on STBD generator
-Bow thruster hydraulic hose wasted, longer than 30 inches
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 30 September 2019
Resolved
Vessel is fitted with machinery space alarm system. The panel for machinery space alarms in E/R was found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Re-attended vessel and cleared deficiencies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 September 2018
Resolved
The port side engine room emergency escape hatch had an cracked and dry rotted gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 6 September 2018
Resolution: Replaced gasket, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 September 2018
Resolved
The E-light for the life float/muster station was inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 6 September 2018
Resolution: Replaced the fixture, all sat.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 June 2017
Resolved
Submit Non-Tank Vessel Response Plan proposal
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 3 October 2017
Resolution: Company provided copy of approved NTVRP.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 June 2017
Resolved
Provide donning placard for lifejackets on Bridge and Accomodations
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 20 July 2017
Resolution: Attended vessel verified donning placards posted.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 June 2017
Resolved
Provide Transfer Procedures and Diagram at Transfer Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 20 July 2017
Resolution: Verified Transfer Procedures and Diagram at Transfer Pump.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 June 2017
Resolved
Replace Handline and Retroreflective tape on STBD Bridge Bouy and 02 level PORT bouy
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 20 July 2017
Resolution: Verified correction of Handline and Retroreflective tape on STBD Bridge Bouy and 02 level PORT bouy.
Communications › Radio Communications › EPIRB
Issued 29 June 2017
Resolved
Provide EPIRB Registration Sticker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 20 July 2017
Resolution: Vessel representative located and placed sticker on EPIRB.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 June 2017
Resolved
Provide First Aid Kits with unexpired contents per Standby Vessel Endorsement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 20 July 2017
Resolution: New first aid kits onbaord
Engineering › Fuel Oil Service System › Filter
Issued 29 June 2017
Resolved
Change all fuel filter bowls to metal. 10 total.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 20 July 2017
Resolution: Fuel bowls replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 March 2016
Resolved
Complete annual testing of CO2 fixed firefighting system in the presence of attending marine inspector: Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2016
Resolution: Witnessed proper testing of Co2 system, all sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 30 March 2016
Resolved
Repair or replace watertight bulkhead penetrations in forward engine room bulkhead. IAW 46CFR116.100: Prior to Sail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2016
Resolution: Inspected water tight penetration, found sealed properly.
Lifesaving › Lifefloat › Painter
Issued 30 March 2016
Resolved
Install painter lines on both lifefloats to the satisfaction of attending Marine Inspector IAW 46CFR133.130 Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2016
Resolution: Replaced line and rerouted properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 March 2016
Resolved
Install nozzle on fixed CO2 for paint locker IAW 46CFR132.310.
Action required: 705 - Other - as specified
Resolved 30 March 2016
Resolution: Nozzel installed.
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 30 March 2016
Resolved
Repair or replace engine tachometer for stbd main engine IAW 46CFR130.120 by 60 days.
Due 30 May 2016
Resolved 1 April 2016
Resolution: Witnessed proper operation
Lifesaving › Lifebuoys › Serviceable
Issued 30 March 2016
Resolved
Replace weathered painter and grabings on ring lite buoys as necessary to the satisfaction of attending [name withheld] 46CFR133.70: Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2016
Resolution: Inspected newly installed ring buoy.