MAURY USCG vessel records
← All vessels

EQUULEUS LEADER

EQUULEUS LEADER is a freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in May 2026, along with 4 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 6 May 2026.

Built
Not recorded
Last inspected
6 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9342906
802888
Flag
JAPAN
Maury page id
psix-802888

Documentation record

Tonnage as PSIX records it62393 - Simplified, Gross Ton
62393 - Convention (Subpart B), Gross Ton
18717 - Simplified, Net Ton
18717 - Convention (Subpart B), Net Ton
38562 - Displacement, Ton
20141 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

6 May 2026 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8357544
28 April 2026 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8357325
10 July 2025 PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8182767
8 October 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7805655
11 August 2023 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7765938
23 March 2023 Ballast Water Examination · PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7654526
11 April 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7428529
23 August 2021 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7294082
20 August 2021 PSC A · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7288158
8 February 2021 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7135397
14 November 2020 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7091617
26 February 2020 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6915998
20 September 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6807515
20 August 2018 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6517412
4 March 2018 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6362634
23 October 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6293652
8 June 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6167955
15 December 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6058542
24 August 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5993701
22 August 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5976168

Deficiency record · 4

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
74SOLAS(04)33.1: Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, and installed as to withstand the mqaximum working stresses to which it may be subjected. PSCO observed 01 steam leaks on the engine room boiler
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 April 2026
Resolution: Gasket for mud hole cover was found to be damaged. Vessel replaced gasket with new spare gasket. Class report satisfactory.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 20 August 2021 Resolved
Each ballast water management system (BWMS) manufactured 46 under Coast Guard approval must have a nameplate securely fastened to the BWMS and plainly marked by the manufacturer with a Coast Guard approval number assigned to the BWMS in the certificate of approval. Vessel's BWMS nameplate did not display the Coast Guard approval number. Vessel was unable to provide a BWMS approval letter.
Action required: 15 - Rectify deficiencies by next port
Due 20 August 2021
Resolved 23 August 2021
Resolution: Vessel provided proof of Ballast Water Extension Letter. Currently, vessel has an extension until their next schedule dry dock after 01OCT2018 so there will not be a Coast Guard approval number.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 November 2020 Resolved
Each emergency generator shall be provided with a second source of energy unless manual starting can be demonstrated. PSCO observed that emergency generator did not have second source of energy and could not be started manually. 74 SOLAS (04) II-1/44.2.1 Action taken: 17(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2020
Resolved 9 February 2021
Resolution: Emergency generator operated satisfactorily during PSC B exam on 08FEB2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2019 Resolved
01 - THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THERE IS A CRACK ON THE TOP OF THE MAIN ENGINE NO.3 CYLINDER LINER. - 74SOLAS(04) CH II-1/26.1 - 17AC
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2019
Resolved 21 September 2019
Resolution: CREW MADE PROPER REPAIRS TO ENGINE AND CLASS APPROVED OF REPAIRS. PLEASE SEE CLASS REPORT IN DOCUMENTS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.