MAURY USCG vessel records Sign in
← All vessels

PACIFIC PROVIDER

PACIFIC PROVIDER is a 2006 offshore supply vessel. The Coast Guard has recorded 6 inspections since 2005, most recently in December 2009.

Records from 2005 to 2009. Most recent: inspection, 10 December 2009.

Built
2006
Last inspected
10 December 2009
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9095084 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH3100
803157
Flag
UNITED STATES
338622000, 367604280
Maury page id
psix-803157

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2005–2009)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)169.0 ft × 46.0 ft × 15.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)169.0 ft × 46.0 ft × 15.0 ft
ITC tonnagegross 878 / net 263
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it878 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
263 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6374MMSI 338622000 · active · compulsorily equipped · granted 21 November 2025, expires 21 November 2035
WDH3100MMSI 367604280 · active · compulsorily equipped · granted 23 December 2023, expires 1 February 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDC9102MMSI 367097610 · expired · voluntarily equipped · granted 8 March 2006, cancelled 14 May 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 6

10 December 2009 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3650517
25 March 2009 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3445673
19 June 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3240889
17 July 2007 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2997942
22 March 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2607255
15 March 2005 Welding Related Inspections Qualification Testing · Plan Review (Other than "T") · Initial Certification · Construction Oversight · Inclining Experiment · Hull Examination · MTSA Verification · Internal Structural Exam · Cargo Tank Internal · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2628684

Deficiency record · 0

No deficiencies recorded against this vessel. This means none were written in the records covered — it is not a statement about the vessel's condition. What a recorded resolution is.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.