Records from 2006 to 2021. Most recent: inspection, 24 September 2021.
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2007
Resolved
Charts not updated 33CFR164.72(b)(1)
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 September 2007
Resolved
No Coast Guard Light List 33CFR164.72 (b)(2)
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 September 2007
Resolved
US Coast Pilot 33CFR164.72(b)(2)
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 September 2007
Resolved
Magnetic compass not at operating Station 33CFR164.72(a)(4)
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Communications › Visual Communication › Signalling Lamp
Issued 26 September 2007
Resolved
No searchlight onboard 33CFR164.72(a)(2)
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 September 2007
Resolved
Life vests need to be type one and marked with vessel name 46CFR26.30-1
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Documentation › Manuals/Policy Documentation › Company Action Plan (SIP)
Issued 26 September 2007
Resolved
EAP placard 46CFR16.401(a)
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 September 2007
Resolved
Dead end wire 33CFR150.113
Condition: Improper/Lack of Maintenance
Due 26 October 2007
Resolved 26 October 2007
Documentation › Markings/Placards › Warning Signs
Issued 26 September 2007
Resolved
General Alarm placard 33CFR150.113
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 26 September 2007
Resolved
No Flame screens on Fuel Vent 46CFR27.211(b)(1)
Condition: Placed in Improper Service
Due 26 October 2007
Resolved 26 October 2007
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 17 February 2006
Resolved
Provide official number clearly visible on interior structural part of hull.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Official number on hull
Lifesaving › Lifejacket/PFD (Type IV) › Quantity
Issued 17 February 2006
Resolved
Provide CG approved life ring buoy with retroreflective material on each side.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Approved ring buoy on board
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 February 2006
Resolved
Provide marine radar.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Operational radar on board
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 17 February 2006
Resolved
Provide searchlight at steering station capable of illuminating at a distance at least twice the length of tow.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Search light provided
Communications › Radio Communications › VHF Radiotelephone
Issued 17 February 2006
Resolved
Provide VHF-FM radio capable of monitoring channels 13 & 16.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: VHF radio installed
Navigation › Piloting/Steering › Magnetic Compass
Issued 17 February 2006
Resolved
Provide magnetic compass readable from steering station.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Compass provided
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 17 February 2006
Resolved
Provide echo depth-sounding device readable from steering station. (Batteries were dead at the time of inspection)
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Echo-depth sounder provided
Communications › Alarms/Indicators › General Alarm
Issued 17 February 2006
Resolved
Provide audible and visual general alarm in all accommodations and working spaces and engine room.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: General alarm provided
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 17 February 2006
Resolved
Provide fire detection system approved under 46 CFR 161.002 or by an independent laboratory.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Fire detection system installed
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 February 2006
Resolved
Provide labels for remote fuel shutoff for each engine and generator marked with 1" letters indicating purpose and direction of operation.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Remote fuel shut off properly marked
Operations/Management › Drills/Instruction › Fire
Issued 17 February 2006
Resolved
Provide log of drills and instructions conducted monthly.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Provided logs
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 February 2006
Resolved
Provide proof of service and testing for portable fire fighting equipment.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Serviced fire extinguishers
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 17 February 2006
Resolved
Provide proof of service and testing on fixed fire fighting for engine room.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: serviced fire extinguishers
Documentation › Logs/Records › Drug Test Records
Issued 17 February 2006
Resolved
Provide proof of enrollment in a drug testing program.
Action required: 705 - Other - as specified
Resolved 6 April 2006
Resolution: Provided proof of drug testing program