Records from 2016 to 2026. Most recent: inspection, 9 March 2026.
Inspection history · 17
9 March 2026
Deficiency Check · In-Service Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8325477
16 October 2025
COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8253627
27 March 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8104785
18 November 2024
Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8038389
24 October 2024
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 8032200
23 January 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7853747
13 December 2022
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7609336
7 December 2021
Drydock Exam · In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7363928
23 April 2021
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7199605
16 January 2021
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7128549
29 October 2020
Plan Review "T" Boat · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082718
25 March 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6931604
19 November 2019
Drydock Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6858101
20 November 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6583889
14 December 2017
Hull Examination · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6322443
27 November 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6313695
23 December 2016
Annual Inspection · DAPI Audit · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6086306
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 December 2021
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. The vessel's port fwd chamber was not holding pressure due to failure of a baffle. The vessel needs to conduct the overpressure "stress" test IAW Sector Honolulu Work Instruction 07 in the presence of an attending Coast Guard Marine Inspector and prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2022
Resolved 27 December 2021
Resolution: Post repair stress test conducted satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Two adult life jackets outer covering were torn.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 January 2022
Resolved 7 December 2021
Resolution: Replaced with new adult life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2021
Resolved
A mechanical exhaust system for gasoline tank compartment consisting of at least two ventilation exhaust ducts. Only one exhaust duct fitted.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2022
Resolved 27 December 2021
Resolution: Second duct fitted.
Construction/Loadline › Hull › Side Shell
Issued 14 December 2017
Resolved
Vessel needs to provide a satisfactory baffle leak test on its foward starboard baffle in accordance with Sector Honolulu's Work Instruction 07.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2017
Resolution: The company repaired the leaking baffle on the inflatable hull.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 December 2017
Resolved
Vessel needs to provide a visual indicator for its inboard bilge pump when operating in both manual and automatic modes.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 3 January 2018
Resolution: The vessel was provided with a visual indicator for its inboard bilge when operating in both manual and automatic modes.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 December 2017
Resolved
Vessel needs to replace 04 adult lifejackets onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 14 December 2017
Resolution: The company replaced the wasted 04 lifejackets with new ones.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 December 2016
Resolved
Vessel needs to be equipped with an approved "Class D" or better VHF-DSC radio.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 9 January 2017
Resolution: Vessel installed an approved "Class D" radio onboard. An operational test of the radio was conducted, all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 December 2016
Resolved
Vessel needs to have a valid FCC Safety Radiotelephony Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 9 January 2017
Resolution: Vessel received a re-newed FCC Safety Radiotelephony Certificate.