← All vessels
NICEA
NICEA is a 1987 freight ship. The Coast Guard has recorded 43 inspections since 2006, most recently in May 2009, along with 27 deficiencies and 24 operational controls.
Records from 2006 to 2009. Most recent: operational control imposed, 2 May 2009.
- Built
- 1987
- Last inspected
- 2 May 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 27 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8606642 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HXG5
803783
Flag
MALTA
—
Maury page id
psix-803783
Inspections, by type
The 43 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it6894 - Convention (Subpart B), Gross Ton
2068 - Convention (Subpart B), Net Ton
4673 - Dead Weight, Ton
2068 - Convention (Subpart B), Net Ton
4673 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 43
2 May 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3465709
28 April 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3459972
28 April 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3463148
24 April 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3458112
21 April 2009
ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3457213
9 April 2009
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3449266
19 February 2009
Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3420400
20 January 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3396834
14 January 2009
PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3392670
14 January 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3394016
12 January 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3392896
29 October 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2809945
26 October 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2808572
25 October 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2808301
24 October 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2806851
24 October 2006
MARPOL Annex I Examination · Deficiency Check · Random ISPS/MTSA-No PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2806998
29 August 2006
ISPS III Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2763073
28 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2762613
28 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2770996
25 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2759653
6 July 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2703666
3 July 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2699978
26 June 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2691917
16 June 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2681383
14 June 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2679498
6 June 2006
ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2671678
17 May 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2651549
16 May 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2650828
14 May 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2649279
9 May 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2645059
6 May 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2642399
29 April 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2636483
28 April 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2635845
21 April 2006
ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2630223
18 April 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2627905
14 April 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2624648
12 April 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2623002
29 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2612041
19 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2605268
5 March 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2596294
2 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2594766
14 January 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2567017
13 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2566250
Deficiency record · 27
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 19 February 2009
Resolved
vessel must provide flag report attesting to proper operations to all equipment and approval to depart Port of Miami.
Engineering › Diesel Engine (propulsion-electric) › Cylinder
Issued 14 January 2009
Resolved
Port MDE #3 has major F/O leak at high pressure pump (approx. 1 per. hour). This leak poses a significant risk of fire in the engine room. Class to attest to repair prior to vessel entering port.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 14 January 2009
Resolved
Port MDE shows signs of water past the O-rings in cylinder block, leaking out of tad tail holes in crankcase.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 January 2009
Resolved
Flammable paint cans (5 Gals.) found in parts storage locker portside. Oily rags found in a 5 gal can (plastic bucket). This condition poses a significant risk of fire in the engine room.
Engineering › Sea-water System (primary cooling) › Pump
Issued 14 January 2009
Resolved
#1 MDE cooling water pump has excessive leaking around packing gland (steady flow)
Engineering › Freshwater System (piston cooling) › Level Control
Issued 14 January 2009
Resolved
STBD MDE has excessive water (cooling) pouring out of crankcase (tad tail holes) a wood plug was stuffed in hole.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 January 2009
Resolved
Temporary repair found on STBD MDE saltwater piping to after cooler
Engineering › Steam Boiler (propulsion) › Piping
Issued 14 January 2009
Resolved
Major steam leak at condensate tank, broken pipe.
Engineering › Steam Boiler (auxiliary/waste heat) › Manhole
Issued 14 January 2009
Resolved
Aux. Boiler inspection cover leaking around sealing area
Fire Fighting › Fire Pumps › Gland Sealing
Issued 14 January 2009
Resolved
Main fire pump packing gland leaking water around stuffing box, gland is bottomed out.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 January 2009
Resolved
Prove proper operation of OWS alarm. The alarm was tested at 17 PPM, vessel states they have not used OWS in last two years. The oil record book supports lack of use. DNV issued Condition of Class to expire 18 Mar 2009 - amended def to prohibit use of OWS in U.S. waters until non-conformity cleared.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 24 October 2006
Resolved
Submit ballast water management plan to NBIC, per 33 CFR 151.2041, prior to entry to United States or Puerto Rico, for each voyage to U.S. or P.R.)
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 August 2006
Resolved
Vessel does not have or has a record of submitting a Non-tank vessel response plan to the Coast Guard. Vessel is required to submit a non-tank vessel response plan to the CG.
Lifesaving › Lifeboat › Markings
Issued 26 June 2006
Resolved
Ship's NON-self righting lifeboats do not have Retro-Reflective Tape placed on the underside of hull.
Construction/Loadline › Hull › Hull Plating
Issued 26 June 2006
Resolved
Ship has two insets in hull (stbd side below pilots gangway). One of the insets appears to have been welded across. The other is approx 18" below the other and is inset 1" and approx. 3" in diameter. Vessel to undergo repair at drydocking in September. Class to provide report of repairs when completed.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 6 June 2006
Resolved
Supplied oar locks for both P/S lifeboats, do not fit in the hloes. Clean and repair the same.
Lifesaving › Lifeboat › Canopy
Issued 6 June 2006
Resolved
Port lifebaot temporary cover support mount ha crack at base for support rod. repair the same.
Navigation › Piloting/Steering › Notices to Navigation
Issued 6 June 2006
Resolved
Vsl is to submitt corrected NOA to correct errors noted by USCG inspectors (i.e. DOB, Nationality and passport# incorrect).
Engineering › Freshwater System (piston cooling) › Piping
Issued 6 June 2006
Resolved
Vsl is to address and repair soft patched/postage stamp pactched piping IWO cooling water piping fro emergency generator and bilge discharge piping (located in lube oil tank room)
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 January 2006
Resolved
Emergency generator is missing required temperature gauges. Submit Flag/Class report attesting to proper repairs to attending USCG Marine Inspector.
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 January 2006
Resolved
Excessive oil in steering gear deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 January 2006
Resolved
Missing light fixture cover holders knobs at purifier room.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 January 2006
Resolved
Missing light fixture cover holders knobs at starboard side engine room aft to oil transfer pump.
Fire Fighting › Fire Hoses › Condition
Issued 14 January 2006
Resolved
Missing fire hose for starboard side main deck fire station forward of CO2 room. While testing fire hose noted the hose was leaking in a sprinkler like way approximately about a 45% the length of the hose. No spares were no board at the time.
Lifesaving › Launching Appliances › Davit
Issued 14 January 2006
Resolved
Inoperative port side lifeboat forward davit arm. While conducting an abandon ship drill, the forward davit arm did not extend while the aft davit arm fully extended. The lifeboat unable to be lowered to the water. Two safety mechanism seem to be failing at the moment o f drill.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 January 2006
Resolved
Excessive wasted areas were found in way off the stairway leading to bridge deck from main deck at swimming pool and stairway leading to upper deck from bridge deck. Submit Flag/Class report attesting to proper repairs to attending USCG Inspector.
Lifesaving › Lifeboat › Hull
Issued 14 January 2006
Resolved
During abandon ship drill, port lifeboat suffered impact damage. Submit Flag/Class report attesting to proper repairs to attending USCG Inspector.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.